• Title/Summary/Keyword: Photovoltaic Field

Search Result 230, Processing Time 0.026 seconds

Consideration of Electrical Properties in Field-aged Photovoltaic Module (태양전지모듈의 노화현상에 따른 전기적 특성 고찰)

  • Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, HyungKeun;Han, Deuk-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.12
    • /
    • pp.1289-1295
    • /
    • 2004
  • In this paper, degradation in field-aged PV modules including degradation of interconnect, discoloration of encapsulant and hot spot have been observed and analyzed. From the results, photovoltaic module installed for 6 years shows around 16 % drop of electrical properties due to the interconnect degradation and PV module passed 18 years has been found to drop of around 20 % mainly by the encapsulant discoloration. Furthermore the difference between low and high temperature of PV array at hot spot goes up to 3$0^{\circ}C$ and it leads to interconnect degradation. On the other hands, the temperature difference was observed to be around 15$^{\circ}C$ at the encapsulant discoloration spot of PV array.

A Case Study on Malfunction of OCGR and Inaccuracy of Watt-hour Meter in Distributed Generation System (분산형 발전고객의 OCGR오동작 및 과부족 계량에 대한 사례연구)

  • Shin, Dong-Yeol;Park, Yong-Woo;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1349-1355
    • /
    • 2008
  • The paper shows the analysis of operating conflict of OCGR trip events and metering errors in the photovoltaic generation, wind generation distributed generation customers with no defect of the distributed generation facilities, which are connected to 22.9kV distribution lines. To analyze problems with metering errors and OCGR fault event, a power quality analyzer and PSIM program were used to test the field and to simulate in Sun-Cheon photovoltaic generation and Seo-Cheon photovoltaic generation customers. With the trial distribution line, the result of analysis was verified to prove with the same situation of the actual field. This paper suggests short term and long term countermeasures of OCGR fault events, analysis of over and shortage of metering errors in distributed generation customers.

Salt Farm Parallel Solar Power System:Field tests and Simulations (염전 병행 태양광 발전의 실증과 시뮬레이션)

  • Park, Jongsung;Kim, Bongsuck;Gim, Geonho;Lee, Seungmin;Lim, Cheolhyun
    • Current Photovoltaic Research
    • /
    • v.7 no.4
    • /
    • pp.121-124
    • /
    • 2019
  • In this research, the concept of a salt farm parallel solar power system, which produce salt and electricity at the same site, is proposed for the first time in the world. The concept is that large waterproof plates made by interconnected solar modules are installed at the bottom of the salt farm. The pilot system was successfully installed at a sea shore, and verified its feasibility as a solar power plant. For deeper understanding, simulations for power prediction of the system were carried out and compared with the field test results. The power generation of the salt farm parallel system is comparable to conventional solar power plants. The cooling effect by sea water contributes more to the increase in the crystalline silicon photovoltaic module performance than the absorption loss due to sea water by maintaining certain height above the module.

A Study on the Tracking Method for Solar Module to Derive Optimum Performance (최적 발전성능 도출을 위한 태양광모듈 추적방법에 관한 연구)

  • Kim, Yongjin;Lee, Jong Soo;Chung, Yu-Gun;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.113-118
    • /
    • 2012
  • The photovoltaic is one of the most important sustainable technologies appliable to architectures. The power performance mainly depends on the installation conditions of them. This study aims to evaluate the power performance of photovoltaic system by the installation conditions, the tracking methods and reflecting mirrors. For the study, the Solar Pro computer simulations have been conducted on installation angles, solar azimuth and solar altitude. Also, the field mock-up tests are performed to of its application to verify the simulation results. Both the results of the experiment and the simulation have proved that the efficiency of 90-degree fixed angle method was higher than that of 30-degree fixed angle, the efficiency of altitude tracking was better than that of azimuth tracking method, and changing both the altitude and the azimuth together is more efficient rather than the shortened tracing way. In addition, the light-concentrating method in which the incidence angle of the sun is controlled by an adhered reflector has been analyzed to have better efficiency than the general method of tracing according to the orbit of the sun. Therefore, this thesis is expected to offer the basic data to set a more effective tracing-type of photovoltaic power generation system in the future. For this, more researches are to be conducted hereafter on a high efficiency drive motor and the establishment of an economic system.

The Effect of Electrical Properties with Degradation of EVA sheet and Electrode in Photovoltaic Module (태양전지모듈의 EVA sheet 열화와 전극부식이 전기적 특성에 미치는 영향)

  • Kang, Gi-Hwan;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.26-28
    • /
    • 2005
  • In this paper, degradation in field-aged PV modules including degradation of interconnect, discoloration of encapsulant and hot spot have been observed and analyzed. From the results, photovoltaic module installed for 15 years shows around 13~20% drop of electrical properties due to the interconnect degradation and PV module passed 19 years has been found to drop of around 20% mainly by the encapsulant discoloration. Fill factor of the electrode oxidized photovoltaic module has been dropped by the amount of 6~10% due to the change of irradiance. It is because maximum voltage(Vmp) decreases according to the increase of irradiance.

  • PDF

A Study on Optimal Design and Electrical Characteristics of 600 V Planar Field Stop IGBT (600 V급 Planar Field Stop IGBT 최적 설계 및 전기적 특성 분석에 관한 연구)

  • Nam, Tae-Jin;Jung, Eun-Sik;Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.4
    • /
    • pp.261-265
    • /
    • 2012
  • IGBT(insulated gate bipolar transistor) is outstanding device for current conduction capabilities. IGBT design to control the large power switching device for power supply, converter, solar converter, electric home appliances, etc. like this IGBT device can be used in many places so to increase the efficiency of the various structures are coming. in this paper optimization design of planar type IGBT and planar field stop IGBT, and both devices have a comparative analysis and reflection of the electrical characteristics.

A Study on the Installation Potential of Photovoltaic System Based on Regional Architectural Data (지역별 건축물 데이터를 활용한 태양광발전시스템 설치 잠재량 산정에 관한 연구)

  • Shin, Min-Su;Lee, Kyung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.29-45
    • /
    • 2019
  • As the solar energy market grows, the need to investigate the potential of photovoltaic system is being highlighted. However, due to the lack of plain field, the system on top of buildings is being exploited. This paper analyzes the potential to install PV systems on the rooftops. First of all, with the aid of a photovoltaic system simulation software, buildings were designed in a specific area based on the architectural data. And then, with the same software, the potential to install photovoltaic system was explored by placing PV modules on the buildings' rooftops. The installation potential was calculated and simulated with consideration for obstacles on the rooftops. The parameters are composed of available area for system installation, area utilization rate, PV system power capacity, operation yield hour per day and performance ratio. In the simulation, 5 sites were analyzed based on their architectural data. In the end, reliable data that can be utilized were collected for the potential to install the system with the photovoltaic system simulation software.

Prediction Study of Solar Modules Considering the Shadow Effect (그림자 효과를 고려한 태양전지 모듈의 발전량 예측 연구)

  • Kim, Minsu;Ji, Sangmin;Oh, Soo Young;Jung, Jae Hak
    • Current Photovoltaic Research
    • /
    • v.4 no.2
    • /
    • pp.80-86
    • /
    • 2016
  • Since the last five years it has become a lot of solar power plants installed. However, by installing the large-scale solar power station it is not easy to predict the actual generation years. Because there are a variety of factors, such as changes daily solar radiation, temperature and humidity. If the power output can be measured accurately it predicts profits also we can measure efficiency for solar power plants precisely. Therefore, Prediction of power generation is forecast to be a useful research field. In this study, out discovering the factors that can improve the accuracy of the prediction of the photovoltaic power generation presents the means to apply them to the power generation amount prediction.

Analysis and Design of Utility Interactive Photovoltaic System with Source Side VAR Compensation (전원측 무효전력 보상기능을 갖는 계통연계형 태양광 발전 시스템의 해석 및 설계)

  • 이상용;고재석;한찬영;이정락;최규하;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.591-594
    • /
    • 1999
  • The application field of photovoltaic system has been increased widely. In the application of photovoltaic system, the utility interactive photovoltaic system(UIPVS) has benefits of not only the home energy saving in domestic system but also reduction of peak power which threaten the capacity of power plant equipment when the maximum power consumption is occurred in daytime. This paper represents the effect of the nonlinear AC load which connected to the UIPVS with parallel connection and introduces the active power filtering(APF) techniques to the UIPVS for the reactive power compensation. The enhancement of source side power quality using APF algorithm is verified using simulation.

  • PDF

Fabrication and Evaluation of Low Concentrator Photovoltaic Modules with Aluminium Reflectors (반사판을 이용한 저집속 집광형 태양광 모듈 제작 및 평가)

  • Jeong, Hye-Jeong;Lee, Young-Woo;Ju, Seong-Min;Lee, Ho-Jae;Boo, Seong-Jae
    • New & Renewable Energy
    • /
    • v.4 no.4
    • /
    • pp.17-22
    • /
    • 2008
  • A low concentrating (< 5X) photovoltaic module with aluminum reflectors is fabricated and evaluated which is designed to reduce the affection of the high temperature to the solar cell modules preventing the efficiency lowering. As results, the output power is increased of 1.97X from the concentrating photovoltaic module which is designed with the concentrating ratio of 2.25X and to control the module temperature cooling the module by air circulation. Also, the effect of the concentrating module with aluminum reflectors on the conventional PV module is investigated at the field. The result shows the increase of the output power more than about 20% and the improvement of the module efficiency of 1.4X in spite of the increase of average module temperature.

  • PDF