• Title/Summary/Keyword: Photovoltaic Field

Search Result 230, Processing Time 0.026 seconds

Effects of Grain Boundaries on Photovoltaic Current and Photoinduced Domain Switching in Ferroelectric Ceramics

  • Kim, Sung-Ryul;Choi, Dong-Gu;Choi, Si-Kyung
    • The Korean Journal of Ceramics
    • /
    • v.6 no.3
    • /
    • pp.262-266
    • /
    • 2000
  • We investigated the effect of the grain size on the photovoltaic current in (Pb$_{1-x}$La$_x$)TiO$_3$ceramics, and the photoinduced domain switching in (Pb$_{0.85}$La$_{0.15}$)TiO$_3$and BaTiO$_3$ceramics. These behaviors in ferroelectric ceramics were attributed to the grain boundary at which photoexcited electrons were trapped. As the charged grain boundary acted as an electro-potential barrier which impeded the movement of electrons, the photovoltaic current showed a peak at a critical grain size. The space charge field built by the electrons trapped at the grain bound-aries was accounted for the photoinduced domain switching, and AE experimental results support well this account.

  • PDF

Distance Between a Wind Turbine and a Photovoltaic Module in a Wind-Photovoltaic Hybrid Generation System (태양광-풍력 하이브리드 발전기에서 태양전지모듈과 풍력발전기 이격거리)

  • Woo, Sang-Woo;Kim, Hong-Woo;Kim, Sung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.58-64
    • /
    • 2009
  • This aim of the study is to demonstrate the effect of a photovoltaic module installed on a small wind-photovoltaic hybrid generation system. Computational fluid dynamics(CFD) is used to interpret the velocity field around the photovoltaic module and the blade areas of a wind turbine. According to the simulation results, it is obvious that x_velocity and y_velocity varies very significantly with time near the photovoltaic module. This would lead to an increase of periodic wind load caused by flow separation at the edge of the photovoltaic module. This study discusses the flow characteristics in term of velocity and frequency analysis. Moreover we suggest a distance between a photovoltaic module and a wind turbine to avoid partially the negative effect caused by the photovoltaic module.

Photovoltaic Generation System Simulation using Real Field Weather Conditions

  • Park, Min-Won;Yu, In-Keun
    • Journal of IKEEE
    • /
    • v.5 no.2 s.9
    • /
    • pp.121-127
    • /
    • 2001
  • Actual system apparatuses are necessary in order to verify the efficiency and stability of photovoltaic(PV) generation systems considering the size of solar panel, the sort of converter type, and the load conditions and so on. Moreover, it is hardly possible to compare a certain MPPT control scheme with others under the exactly same weather and load conditions as well. For the purpose of solving above mentioned difficulties in a laboratory basis, a transient simulation of PV generation system using real field weather conditions is indispensable. A straightforward simulation scheme with cost effective hardware structures under real weather conditions is proposed in this paper using EMTDC type of transient analysis simulators. Firstly, a solar cell has been modeled with VI characteristic equations, and then the real field data of weather conditions are interfaced to the EMTDC through Fortran program interface method. As a result, the stability and the efficiency analysis of PV generation systems according to various hardware structures and MPPT controls are easily possible under the exactly same weather conditions.

  • PDF

Observation of Electrical Properties in Field-aged Photovoltaic Module (Field aged 태양전지모듈의 노화현상에 따른 전기적 특성 관찰)

  • Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.28-32
    • /
    • 2004
  • In this paper, degradation in field-aged PV modules including degradation of interconnect, discoloration of encapsulant and hot spot have been observed and analyzed. From the results, photovoltaic module installed for 6 years shows around 16% drop of electrical properties due to the interconnect degradation and PV module passed 18 years has been found to drop of around 20% mainly by the encapsulant discoloration. Furthermore the difference between low and high temperature of PV array at hot spot goes up to $30^{\circ}C$ and it leads to interconnect degradation. On the other hands, the temperature difference was observed to be around $15^{\circ}C$ at the encapsulant discoloration spot of PV array.

  • PDF

Losses Comparison and Analysis for Fault Modes of Grid-connected Photovoltaic System (계통연계형 태양광발전 시스템의 고장유형별 손실 비교분석)

  • So, Jung-Hun;Ko, Suk-Whan;Ju, Young-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.23-32
    • /
    • 2017
  • This paper presents losses comparison and analysis results for different types of fault modes of grid-connected photovoltaic system generated for long-term operation. The approach of losses comparison and analysis by faults is to identify relationship between measured and estimated values of five loss factors which are quantified from irradiance to system output power. This paper presents the symptom results for faults such as snow, shading, sensor defect, blackout, soiling and so on from three years or more monitored data. These results will indicate that it is useful to develop fault detection and diagnosis tool to enhance capacity factor and save operation and maintenance cost of grid-connected photovoltaic system in the field.

Performance of Photovoltaic Module according to Non-Uniform Azimuth (비동일한 방위각에 의한 PV모듈의 발전성능)

  • Kim, Hyun-Il;Park, Kyung-Eun;Lee, Ki-Ok;Kang, Gi-Hwan;Yu, Gwon-Jong;Suh, Sung-Jik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.303-308
    • /
    • 2009
  • In 2008, the global photovoltaic(PV) market reached 5.6GW and the cumulative PV power installed totalled almost 15GW compared to 9GW in 2007. Due to a favourable feed-in-tariff, Korea emerged in 2008 as the 4th largest PV market worldwide. PV power installation rose 495.5 percent to 268MW in 2008 compare to 45MW in 2007. However many PV systems are not installed in suitable part which is concerned about geometrical factor. It is generally recognized that the actual output of PV system in field is a function of orientation, tilt angle, irradiance, temperature, soiling and various system-related losses. Thus this paper shows that a experimental result of PV modules(A group) with uniform azimuth angle and PV modules(B group) with non-uniform azimuth angle. As a result, the electrical output of B group is decreased 48.8% as compared with electrical output of A group.

  • PDF

Characterization of Photovoltaic Module Encapsulant According to UV Irradiation Dose (자외선 조사량에 따른 태양전지 모듈 봉지재의 특성 분석)

  • Lee, Song-Eun;Bae, Joon-Hak;Shin, Jae-Won;Jeon, Chan-Wook
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.81-85
    • /
    • 2018
  • The photovoltaic modules installed in the actual field are affected by various external environments and the electrical performance output value is generally lowered compared to initial output value. The most of photovoltaic modules consists of low iron glass, encapsulant (EVA), back sheet, frame and junction box assembly based on the solar cells. In this paper, the characteristics of encapsulant which is an important constituent material of photovoltaic module were verified by maximum power determination, electro luminescence images, yellowness index measurement, and gel content measurement after ultraviolet (UV) irradiation exposure. The most commonly installed 72 cells crystalline photovoltaic modules were tested after various UV exposure of 0, 15, 30, and $60kWh/m^2$ and compared with the reference module. After UV exposure of $15kWh/m^2$, which is the current international test condition, a small amount of change was observed in yellowness index and electroluminescence, while a gell content rapidly increased. At a cumulative dose of $60kWh/m^2$, which will be a new international test condition in the near future, however, the yellowness index increased sharply and showed the greatest output power drop.

The design and performance characteristic of transformerless inverter for the photovoltaic system (변압기 없는 태양광 발전용 인버터의 제작 및 성능 특성)

  • Ahn, Kyo-Sang;Lim, Hee-Chun;Kim, Sin-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1368-1370
    • /
    • 2003
  • In this paper, the design and performance characteristics of a 3 kW class transformerless photovoltaic inverter was introduced. The field test results of the photovoltaic power inverter showed that the excellence of power quality, the characteristic of starting waveform, the stability and reliability of operation.

  • PDF

A Study on Field Ring Design of 600 V Super Junction Power MOSFET (600 V급 Super Junction MOSFET을 위한 Field Ring 설계의 관한 연구)

  • Hong, Young-Sung;Jung, Eun-Sik;Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.4
    • /
    • pp.276-281
    • /
    • 2012
  • Power semiconductor devices are widely used as high voltage applications to inverters and motor drivers, etc. The blocking voltage is one of the most important parameters for power semiconductor devices. Generally most of field effect concentrations shows on the edge of power devices. Can be improve the breakdown characteristic using edge termination technology. In this paper, considering the variables that affect the breakdown voltage and optimization of parameters result for 600 V Super Junction MOSFET Field ring.

Field Test Study of Photovoltaic Generation System for Medium and Small-Sized Buildings (중소형 건물 태양광발전시스템의 실증 연구)

  • Kim, Eung-Sang;Kim, Seul-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.561-565
    • /
    • 2006
  • The paper presents a method of assessing the adequate tapaclty of photovoltaic generation systems for public buildings based on analysis of load variation patterns of customers. When PV systems are installed for supplying power for the customer load, reverse power relay is required by the guideline to be installed at the point of common coupling with the power network. The suggested method analyzes daily, weekly and monthly load demand of the customer that Irishes PV system installation, and determines the appropriate rating of the PV system for preventing PV generation from exceeding the customer demand. This work is expected to support renewable energy dissemination projects of public organizations.

  • PDF