• Title/Summary/Keyword: Photovoltaic(PV)

Search Result 1,345, Processing Time 0.029 seconds

A Study on Power Generation Efficiency through the Post Evaluation of Photovoltaic Panels in Complex Type Buildings - Focused on Annual Generation Performance of S-university - (단지형 건물군 내 태양광 패널의 사후 평가를 통한 발전 효율 연구 - S대학의 연간 발전 실적을 중심으로 -)

  • Kim, Heejin;Jung, Hyejin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.5
    • /
    • pp.11-19
    • /
    • 2017
  • The purpose of this study is to analyze the efficiency of PV according to installation condition in the complex type buildings. For this purpose, annual performance of solar power generation in a certain area was investigated and various methods were conducted including post operation evaluation. In addition, we tried to find out influencing factors that affect the efficiency and sought to identify their relative impact of degree through the data analysis and site visits together. In the middle of this process we can draw up major considerations for the efficient photovoltaic power generation installation. In the mean while, previous studies are making something new related with method for efficiency enhancement and individual influential factors based on experimental environment rather than the empirical data site based. As a result of the study, it was confirmed that even if installed in the same area, the power generation efficiency is 1.5 times as high as the installation condition. Furthermore, statistical analyses were performed on azimuth, tilted angle and shade, which are variables affecting conversion efficiency, and it was statistically confirmed that all variables are meaningful factors that affect the conversion efficiency which is a dependent variable. The most influential factor is the azimuth, followed by the tilted angle and the shade factor. From this result, we expect to be able to provide installation guidelines for the solar power generation equipments on the rooftop zone.

A Study on the Application of BIPV for the Spread of Zero Energy Building (제로에너지 건축물 확산을 위한 건물 일체형 태양광 적용방안 연구)

  • Park, Seung-Joon;Jeon, Hyun-Woo;Lee, Seung-Joon;Oh, Choong-Hyun
    • Journal of Digital Convergence
    • /
    • v.19 no.9
    • /
    • pp.189-199
    • /
    • 2021
  • In order to increase the self-reliance rate of new and renewable energy in order to respond to the mandatory domestic zero-energy buildings, the taller the building, the more limited the site area, and installing PV modules on the roof is not enough. Therefore, BIPV (Building integrated photovoltaic, hereinafter BIPV) is the industry receiving the most attention as a core energy source that can realize zero-energy buildings. Therefore, this study conducted a survey on the problems of the BIPV industry in a self-discussing method for experts with more than 10 years of experience of designers, builders, product manufacturers, and maintainers in order to suggest the right direction and revitalize the BIPV industry. Industrial problems of BIPV adjustment are drawn extention range of standard and certification for products, range improvement for current small condition of various kind productions, need to revise standards for capable of accomodating roof-type, color-module and louver-module, necessary of barrier in flow of foreign modules into korea through domestic certification mandatory, difficulty in obtaining BIPV information, request to prevent confusion among participants by exact guidelime about architectural application part of BIPV, and lack of the BIPV definition clearness, support policy, etc. Based on the improvements needed for the elements, giving change and competitiveness impacts aims to present and propose counter measures and direction.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

Study on the Long-term Reliability of Photovoltaic Module in the Cell level (태양전지의 Cell 레벨에서의 장기 신뢰성에 관한 연구)

  • Kim, Koung-Hwan;Jeon, Yu-Jae;Kim, Do-Sok;Jo, Il-Jea;Shin, Young-Eui
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.177-181
    • /
    • 2012
  • 본 연구는 고온고습 시험을 통하여 Cell 레벨에서의 표면관찰 및 효율저하를 분석하였다. 고온고습 시험 조건은 KS C IEC-61215에서 제시한 PV module하의 조건을 이용하여 온도 $85^{\circ}C$, 습도 85% 조건하에 1000시간 동안 수행하였다. 고온고습 시험에 따라 효율에 직접적인 영향을 줄 수 있는 이상 유 무를 Cell 표면을 통해 분석한 결과, 고온고습 시험 수행 중 부분적으로 변색되는 것을 확인하였다. 고온고습 시험 전 단결정 Cell의 효율은 17.74% 였으며, 1000시간 수행 후 15.63%으로 11.89%의 감소율을 보였다. 다결정 Cell의 시험 전 효율은 15.46%, 1000시간 수행 후 효율은 14.02%로 9.31%의 감소율을 보였다. 경년 시 나타나는 전기적 특성을 분석하기 위해 FF(Fill Factor)값을 분석한 결과, 고온고습 시험 전 단결정 Cell은 78.71%에서 75.01%로 4.7%의 감소율을 보였으며, 다결정 Cell은 78.10 %에서 76.66%로 1.84%의 감소율을 보였다. 효율 및 FF값에서 단결정 Cell이 다결정 Cell보다 감소율이 큰 것으로 분석되었으며, 이는 단결정 Cell이 외부 환경에서 더욱 크게 작용하여 효율저하에 영향을 주었다고 판단된다.

  • PDF

Realtime Monitoring system of Residential Photovoltaic system (주택용 태양광발전시스템의 실시간 모니터링 기술)

  • Lim J.Y.;Kang B.B.;Yoon J.P.;Park S.J.;Yoon P.H.;Cha I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.953-956
    • /
    • 2003
  • Digital environment that is represented to internet is displacing business way of industry and business achievement way with the fast speed being giving great change on life whole, improve existence business process utilizing internet and Web connection technology, information superhighway to tradition industrialist manufacture and e-transformation's propulsion that wish to maximize productivity and administration efficiency Is spread vigorously. In this paper, we wish to accomplish generation equipment's heighten stability and believability through remote monitoring and control of PV system. This paper describes the design of the monitoring system for sensing the monitoring data and indirect controlling of the PV system. Most of the conventional monitoring system depend on the special hardware and software. Basic design goal of monitoring system is to provide the convenience for the user and the portability for the system. In order for the system to fulfill its requirements, it was designed using Labview GUI facility based on the Windows 2000 environment of IBM PC compatible and Add-on card based on the TCP/IP protocol. Advantage of the monitoring system are a personnel expenses curtailment effect, free of the place restriction and unmanned system of the generation plants, etc..

  • PDF

Photovoltaic Generation System Design for Controlling the Temperature and Humidity of Hospital (병원내 온도와 습도조절을 위한 태양광 발전 시스템 설계)

  • Cho, Moon-Taek;Lee, Chung-Sik;Baek, Jong-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.127-134
    • /
    • 2011
  • In this paper we propose an improved PV generation systems. Improved systems for temperature and humidity controlled heating and air conditioning offers a pleasant environment within the building, set up chopper and consists of a PWM voltage type inverter. The proposed system is stable modulation for a one-chip microprocessor using the synchronous signal and control signals was treated. The proposed system is a PWM voltage type inverter and phase of the synchronous to the grid voltage to detect the system voltage and inverter output to drive the statue, so surplus power to connection was able to, certain buildings such as buildings or hospitals, temperature and humidity sensor is applied to the good dynamic characteristic could be obtained. In addition, the system was applied to the high power factor and low-frequency harmonics by maintaining the output load and grid to power to be supplied to a stable control could get a good result.

Analysis of degradation by hotspot heating in amorphous silicon PV module (a-Si 태양전지 모듈의 hotspot에 의한 열화현상 연구)

  • Yoon, Na-Ri;Jung, Tae-Hee;Min, Yong-Ki;Kang, Ki-Hwan;Ahn, Hyeung-Keun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.17-22
    • /
    • 2011
  • There are some degradation factors for amorphous silicon solar cells. Light inducing is one of the factor that explained by Staebler-Wronski effect. Also, hotspot heating could be the reason that makes amorphous silicon solar cell degrade. Hotspot heating is occurred when a solar cell is shaded so this work is investigated into two types of shading condition and how these affect to solar cell differently. Reduced irradiance for whole cell and partially shaded as 0($W/m^2$) while the other part of cell is soaking as 1000($W/m^2$) of irradiance are two conditions that are experimented. The two types of shading show different characteristics of degradations. The result shows that partially shaded cell dropped maximum powerless and slower. Also sudden drop points have shown that should be concerned to decide the number of cells for a string. Otherwise, the current through a shaded cell might flow more than cell's capability. It makes cell and module damaged. This work would help to manufacture modules.

  • PDF

Patents and Papers Trends of Solar-Photovoltaic(PV) Technology using LDA Algorithm (LDA알고리즘을 활용한 태양광 에너지 기술 특허 및 논문 동향 연구)

  • Lee, Jong-Ho;Lee, In-Soo;Jung, Kyeong-Soo;Chae, Byeong-Hoon;Lee, Joo-Yeoun
    • Journal of Digital Convergence
    • /
    • v.15 no.9
    • /
    • pp.231-239
    • /
    • 2017
  • Solar energy is attracting attention as an alternative to fossil fuels. However, there was a lack of discussion on the overall research direction and future direction of research in technology development. In order to develop more effective technology, we analyzed and discussed the technology trend of solar energy using patent data and thesis data. As an analysis method, topics were selected by using topic modeling and text mining, the increase of included keywords was analyzed, and the direction of development of solar technology was analyzed. Research on solar power generation technology is expected to proceed steadily, and it is analyzed that intensive research will be done especially on high efficiency and high performance technology. Future studies could be conducted by adding overseas patent data and various paper data.

Determination of the Strength Characteristics of c-Si Solar Cells using Partially Processed Solar Cells (부분공정 태양전지를 이용한 결정질 태양전지의 강도 특성에 관한 연구)

  • Choi, Su Yeol;Lim, Jong Rok
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.5
    • /
    • pp.35-45
    • /
    • 2020
  • Photovoltaic (PV) power system prices have been steadily dropping in recent years due to their mass production and advances in relevant technology. Crystalline silicon (c-Si wafers) account for the largest share of the price of solar cells; reducing the thickness of these wafers is an essential part of increasing the price competitiveness of PV power systems. However, reducing the thickness of c-Si wafers is challenging; typically, phenomena such as bowing and cracking are encountered. While several approaches to address the bowing phenomenon of the c-Si solar cells exist, the only method to study the crack phenomenon (related to the strength of the c-Si solar cells) is the bending test method. Moreover, studies on determining the strength properties of the solar cells have focused largely on c-Si wafers, while those on the strength properties of front and rear-side electrodes and SiNx, the other components of c-Si solar cells, are scarce. In this study, we analyzed the strength characteristics of each layer of c-Si solar cells. The strength characteristics of the sawing mark direction produced during the production of c-Si wafers were also tested. Experiments were conducted using a 4bending tester for a specially manufactured c-Si solar cell. The results indicate that the back side electrode is the main component that experienced bowing, while the front electrode was the primary component regulating the strength of the c-Si solar cell.

A Stable Operation Strategy in Micro-grid Systems without Diesel Generators

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.114-123
    • /
    • 2018
  • Recently, as one of the countermeasures to reduce carbon dioxide($CO_2$) for global warming problems, operation methods in micro-grid systems replacing diesel generator with renewable energy sources including wind power(WP) and photovoltaic(PV) system have been studied and presented in energetic manners. However, it is reported that some operation problems in micro-grid systems without diesel generator for carbon-free island are being occurred when large scaled WP systems are at start-up. To overcome these problems, this paper proposes an operation strategy in micro-grid systems by adapting control devices such as CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage regulation, load control ESS for balancing demand and supply and SVC(static-var compensator) for reactive power compensation. From the simulation results based on the various operation scenarios, it is confirmed that the proposed operation strategy in micro-grid systems without diesel generators is a useful tool to perform a stable operation in micro-grid systems without diesel generator and also make a contribution to reduce carbon dioxide in micro-grid systems.