• Title/Summary/Keyword: Photon energy

Search Result 641, Processing Time 0.03 seconds

Feasibility of clay-shielding material for low-energy photons (Gamma/X)

  • Tajudin, S.M.;Sabri, A.H.A.;Abdul Aziz, M.Z.;Olukotun, S.F.;Ojo, B.M.;Fasasi, M.K.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1633-1637
    • /
    • 2019
  • While considering the photon attenuation coefficient (${\mu}$) and its related parameters for photons shielding, it is necessary to account for its transmitted and reflected photons energy spectra and dose contribution. Monte Carlo simulation was used to study the efficiency of clay ($1.99g\;cm^{-3}$) as a shielding material below 150 keV photon. Am-241 gamma source and an X-ray of 150 kVp were calculated. The calculated value of ${\mu}$ for Am-241 is higher within 5.61% compared to theoretical value for a single-energy photon. The calculated half-value layer (HVL) is 0.9335 cm, which is lower than that of ordinary concrete for X-ray of 150 kVp. A thickness of 2 cm clay was adequate to attenuate 90% and 85% of the incident photons from Am-241 and X-ray of 150 kVp, respectively. The same thickness of 2 cm could shield the gamma source dose rate of Am-241 (1 MBq) down to $0.0528{\mu}Sv/hr$. For X-ray of 150 kVp, photons below 60 keV were significantly decreased with 2 cm clay and a dose rate reduction by ~80%. The contribution of reflected photons and dose from the clay is negligible for both sources.

GAMMA-SPECTROMETRY IN ENVIRONMENTAL MONITORING OF NUCLEAR POWER

  • Cechak, Tomas;Gerndt, Josef;Kluson, Jaroslav;Musilek, Ladislav;Thinova, Lenka
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.203-206
    • /
    • 2001
  • The mathematical processing (unfolding) of pulse height spectra from a scintillation detector helps to calculate the photon fluence rate energy distribution in a measured photon field. The data processing is based on the knowledge of detection system response function and directional dependence respectively. The experimental results of the photon fields measurements in the vicinity of the spent fuel temporary storage and inside the storage hall are presented. The containers Castor 440 are used for temporary storing of the burnt up fuel assemblies in the Czech nuclear power plant Dukovany. A set of periodical measurements was performed in order to get basic information on the time dependence of the photon fields spatial distributions and spectral characteristics in the temporary storage hall and its vicinity. The photon fields were measured by the scintillation system. The obtained photon fields spatial distributions and spectral characteristics present the information on the radiation hazard in the storage.

  • PDF

High Energy Photon Beam Modeling Using Transport Theory for Calculation of Absorbed Dose Distribution (흡수 선량 분포의 수송방정식을 이용한 10 MV X-선의 모델)

  • Choi, Dong-Rak;Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.115-120
    • /
    • 1992
  • A mathematical model is presented for the calculation of the depth absorbed dose in water Phantom irradiated by high energy Photon beam (10MV X-ray), based on transport theory. The parameters of this model are obtained from the experimental values which were simulated by non-linear regression process method. The calculated absorbed dose distribution is extended to 3-D by using trial function from beam profile field sizes, SSD and depth in water phantom irradiated by high energy Photon beam. The calculated values using this model are in good agreement with the measured values.

  • PDF

Radiation mechanism of gamma-ray burst prompt emission

  • Uhm, Z. Lucas;Zhang, Bing
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.49.3-50
    • /
    • 2015
  • Synchrotron radiation of relativistic electrons is an important radiation mechanism in many astrophysical sources. In the sources where the synchrotron cooling timescale is shorter than the dynamical timescale, electrons are cooled down below the minimum injection energy. It has been believed that such fast-cooling electrons have a power-law distribution in energy with an index -2, and their synchrotron radiation has a photon spectral index -1.5. On the other hand, in a transient expanding astrophysical source, such as a gamma-ray burst (GRB), the magnetic field strength in the emission region continuously decreases with radius. Here we study such a system, and find that in a certain parameter regime, the fast-cooling electrons can have a harder energy spectrum. We apply this new physical regime to GRBs, and suggest that the GRB prompt emission spectra whose low-energy photon spectral index has a typical value -1 could be due to synchrotron radiation in this moderately fast-cooling regime.

  • PDF

Uranium Analysis in Aqueous Samples by Selective Extraction and Photon-Electron Rejecting Alpha Liquid Scintillation $(PERALS^\circledR)$ Spectrometry

  • Shin, Hyun-Sang;Lee, Myung-Ho;Park, Geun-Sik;Lee, Chang-Woo
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.445-454
    • /
    • 1999
  • This work describes the adaptation of extractive scintillation by URAE $X^{TM}$ with a photon-electron rejecting alpha liquid scintillation (PERAL $S^{)}$ spectrometer to the analysis of uranium in aqueous samples. The extraction efficiency of the system was evaluated under varing chemical conditions including pH, and sample-cocktail volume ratio. Isotopic information from the (PERAL $S^{)}$ spectrum of natural uranium was obtained using a curve fitting routine. Comparisons of the result with that obtained from alpha spectrometry method using ion implanted silicon detector showed good agreement.t.

  • PDF

Calculation of the Coupled Photon-Electron Slowing Down Energy Spectrum in a Homogeneous, Infinite Tissue Equivalent Material (무한평판(無限平板) 조직등가(組織等價) 물질(物質)에서 광자(光子)-전자결합(電子結合) 감속(減速) 에너지 스펙트럼의 계산(計算))

  • Chung, Chan-Young;Jae, Won-Mok;Lee, Soo-Yong;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.1
    • /
    • pp.26-32
    • /
    • 1983
  • A somewhat detailed energy spectra in terms of the track length resulting from coupled electron-photon slowing down are calculated throughout the ICRU standard tissue with uniformly distributed gamma sources of $^{60}Co\;and\;^{137}Cs$, respectively. The calculation was accomplished by utilizing the latest available cross-section data as input to a carefully optimized computer code. In this report, the calculational method is described in detail. Furthermore, results of calculations are given in graphical form. The results show that the energy spectrum defined in terms of differential track length has about same shape although the energies of gamma source are different. The discontinuity in the energy spectrum appears at the energy of $T=(1/T_0+2/m_0c^2)^{-1}$, because a primary photon can not be degrade to a point below this energy.

  • PDF

Energy Response in Chemiluminescence Dosimetry with Sugar and Sorbite

  • Jun, J.S.;Guggenberger, R.;Dalheimer, A.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.626-637
    • /
    • 2001
  • A series of study on energy dependence in chemiluminescence dosimetry with sugar and sorbite produced in two different countries was carried out administering a dose of 5 Gy to the samples at six different mean photon energies of 30, 50, 80, 130, 662 and 1250 keV. The results revealed distinct energy dependence of chemiluminescence(CL) output of sugar and sorbite. Although the energy dependence, in general, could be fitted by a polynomial of (os E, with I being radiation energy, up to cubic term, we reached a conclusion that the adoption of a fitting function, $y_{R}$$^{=a}$.(1-e $^{-b.logE}$)$^{c}$ +d, deduced from theoretical energy response curve calculated as the ratio of the mass energy absorption of the samples of interest to the soft tissue is more reasonable and rational. Herecoefficients $y_{R}$ is CL intensity, and a, b, c and d are constants to be determined in the fitting process. Energy dependence of relative sensitivities of one sample to the other, discrepancy in sensitivities of the samples from the two countries, and prominent grain size effect in Sorbitol were also shown.shown.

  • PDF

Near-IR Quantum Cutting Phosphors: A Step Towards Enhancing Solar Cell Efficiency

  • Jadhav, Abhijit P.;Khan, Sovann;Kim, Sun Jin;Cho, So-Hye
    • Applied Science and Convergence Technology
    • /
    • v.23 no.5
    • /
    • pp.221-239
    • /
    • 2014
  • The global demand for energy has been increasing since past decades. Various technologies have been working to find a suitable alternative for the generation of sustainable energy. Photovoltaic technologies for solar energy conversion represent one of the significant routes for the green and renewable energy production. Despite of remarkable improvement in solar cell technologies, the generation of power is still suffering with lower energy conversion efficiency, high production cost, etc. The major problem in improving the PV efficiency is spectral mismatch between the incident solar spectrum and bandgap of a semiconductor material used in solar cell. Luminescent materials such as rare-earth doped phosphor materials having the quantum efficiency higher than unity can be helpful for photovoltaic applications. Quantum cutting phosphors are the most suitable candidates for the generation of two or more low-energy photons for the absorption of every incident high-energy photons. The phosphors which are capable of converting UV photon to visible and near-IR (NIR) photon are studied primarily for photovoltaic applications. In this review, we will survey various near IR quantum cutting phosphors with respective to their synthesis method, energy transfer mechanism, nature of activator, sensitizer and dopant materials incorporation and energy conversion efficiency considering their applications in photovoltaics.

Study on the 6 MV Photon Beam Characteristics and Analysis Method from Medical Linear Accelerators Using Geant4 Medical Linac2 Example (GEANT4 Medical Linac2 예제를 이용한 6 MV 선형가속기 광자선속의 기초특성과 연구방법)

  • Kim, Byung-Yong;Kim, Hyung-Dong;Kim, Sung-Jin;Oh, Se-An;Kang, Jung-Gu;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, Geant4 based Monte Carlo simulations were carried out for medical linear accelerator. Modified Medical Linac2 toolkit was used for calculation. The energy spectrum, most probable energy and the photon mean energy compared with the published results using the EGS4 code. The results well agreed with published results. The calculated results of photon fluence, energy fluence and mean energy according to the radius from the centre of the beam were analyzed. Monte Carlo simulation using Medical Linac2 code is considered to be useful for analysis of medical linear accelerator. Because the calculated results varies depending on Physics List model for same head structure. It it important to choose the right model for research purpose. Monte Carlo simulation using GEANT4 Medical Linac2 is a valuable for any novice to adopt this code to the study related to 6 MV photon fluence from medical linear accelerator.