The Kwinana Shoreline Fumigation Experiment in Western Australia, Australia

  • Yoon, I.H.;Sawford, B.L;Manins, P.C.
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 1996년도 봄 학술발표회 초록집
    • /
    • pp.22-22
    • /
    • 1996
  • ;The Kwinana Shoreline Fumigation Experiment(KSFE) took place in Fremantle, WA, Australia between 23 January and 8 February, 1995. All measurement systems performed to expectation. The CSIRO DAR(Division of Atmospheric Research) LIDAR measured plume sections from near the Kwinana Power Station(KPS) stacks to up to about 5 km downstream. It also measured boundary layer aerosols and the structure of the boundary layer on some occasions. Both stages A and C of KPS were used as tracers at different times. Radiosonde and double theodolite sounding systems measured temperature, humidity, air pressure and wind structure at the coast(Woodman Point) and at the inland(ALCOA residue dump) site at intervals of roughly two hours. These were supplemented by mid afternoon soundings(radiosonde and single theodolite) by Department of Environmental Protection(DEP) at Swanbourne. The Flinders aircraft measured wind, turbulence and temperature structure of the atmospheric boundary layer, concentrations of $C0_2,\;0_3,\;S0_2\;and\;NO_x$ in the smoke plumes and surface radiation over both land and sea. CSIRO DCET(Division of Coal and Energy Technology) vehicle successfully interceptde many smoke plumes and using a range of tracers will be able to identify the various sources much of the time. Routine data from the DEP and Kwinana Industrial Council(KIC) air quality monitoring networks were also automatically logged. Murdoch University measured surface heat flux at Hope Valldy monitoring station and also at Wattleup monitoring station for the last five days. The heart of the LIDAR system is a Neodymium-doped Yttrium-aluminumgarnet(Nd:Y AG) laser operating at a fundamental wavelength of 1064 nm, with harmonics fo 532 nm and 355 nm. A small fraction of the laser beam is scattered back to the LIDAR, collected by a telescope and detedted by a photomultiplier tube. The intensity of the signal as a function of time is a measure of the particle concentration as a function of distance along the line of the laser shot. The results of nine days special field observations are summarized in detail.etail.

  • PDF

UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터 (A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector)

  • 정완영;이승철
    • 한국정보통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.158-163
    • /
    • 2008
  • UV기술에 기반한 오존모니터는 신호의 안정성 때문에 널리 활용되어오고 있다. 먼저 오존 발생기에서 나오는 오존농도를 실시간, 고정 밀로 측정하기 위해서 저압 수은램프를 UV광원으로 하고, 광증배관을 UV 감지기로 하는 시스템을 구성하였다. 이 구조는 저 비용의 고농도 오존의 계측에 유용한 시스템으로서 단순한 구조와 비교적 우수한 계측성 능을 얻을 수 있었다. 제조된 시스템은 $0.05{\sim}2w1.%$의 측정 농도영역에서 좋은 선형성을 나타내었다. ppm정도의 보다 정밀한 농도계측을 위해서는 UV광원으로서 고출력 펄스 크세논램프를 사용하고, CCD어레이를 광스펙트로메터로 사용하도록 시스템을 설계하였다. CCD출력으로부터의 광신호는 우수한 반응성과 띄어난 광해상도를 가지고 디지털신호로 변환되고, 이 디지털신호는 PC의 스크린에 디스플레이 되도록 설계되었다. 제작된 시스템은 $10{\sim}10,000ppm$ 영역에서 선형적이고 우수한 감도를 보였으며 저 농도의 오존을 측정하는 시스템으로서의 가능성을 보여주었다.

Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields

  • Lee, Minju;Lee, Daehee;Ko, Eunbie;Park, Kyeongjin;Kim, Junhyuk;Ko, Kilyoung;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1029-1035
    • /
    • 2020
  • The detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random co-incidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve using the peak point of the previous pulse and the start point of the pileup pulse. The amplitude at the corrected start point of the pileup pulse can be estimated by the peak time of the pileup pulse. The system is composed of a NaI (Tl) scintillation crystal, a photomultiplier tube, and an oscilloscope. A 61 μCi 137Cs check-source was placed at a distance of 3 cm, 5 cm, and 10 cm, respectively. The gamma energy spectra for the radioisotope of 137Cs were obtained to verify the proposed method. As a result, the correction of the pulse pileup through the proposed method shows a remarkable improvement of FWHM at 662 keV by 29, 39, and 7%, respectively.

A feasibility study of using a 3D-printed tumor model scintillator to verify the energy absorbed to a tumor

  • Kim, Tae Hoon;Lee, Sangmin;Kim, Dong Geon;Jeong, Jae Young;Yang, Hye Jeong;Schaarschmidt, Thomas;Choi, Sang Hyoun;Cho, Gyu-Seok;Kim, Yong Kyun;Chung, Hyun-Tai
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3018-3025
    • /
    • 2021
  • The authors developed a volumetric dosimetry detector system using in-house 3D-printable plastic scintillator resins. Three tumor model scintillators (TMSs) were developed using magnetic resonance images of a tumor. The detector system consisted of a TMS, an optical fiber, a photomultiplier tube, and an electrometer. The background signal, including the Cherenkov lights generated in the optical fiber, was subtracted from the output signal. The system showed 2.1% instability when the TMS was reassembled. The system efficiencies in collecting lights for a given absorbed energy were determined by calibration at a secondary standard dosimetry laboratory (kSSDL) or by calibration using Monte Carlo simulations (ksim). The TMSs were irradiated in a Gamma Knife® IconTM (Elekta AB, Stockholm, Sweden) following a treatment plan. The energies absorbed to the TMSs were measured and compared with a calculated value. While the measured energy determined with kSSDL was (5.84 ± 3.56) % lower than the calculated value, the energy with ksim was (2.00 ± 0.76) % higher. Although the TMS detector system worked reasonably well in measuring the absorbed energy to a tumor, further improvements in the calibration procedure and system stability are needed for the system to be accepted as a quality assurance tool.

Efficient design of a ∅2×2 inch NaI(Tl) scintillation detector coupled with a SiPM in an aquatic environment

  • Kim, Junhyeok;Park, Kyeongjin;Hwang, Jisung;Kim, Hojik;Kim, Jinhwan;Kim, Hyunduk;Jung, Sung-Hee;Kim, Youngsug;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1091-1097
    • /
    • 2019
  • After the Fukushima accident in 2011, there has been increased public concern about radioactive contamination of water resources through fallout in neighboring countries. However, there is still no available initial response system that can promptly detect radionuclides. The purpose of this research is to develop the most efficient gamma spectrometer to monitor radionuclides in an aquatic environment. We chose a thallium-doped sodium iodide (NaI(Tl)) scintillator readout with a silicon photo multiplier (SiPM) due to its compactness and low operating voltage. Three types of a scintillation detector were tested. One was composed of a scintillator and a photomultiplier tube (PMT) as a reference; another system consisted of a scintillator and an array of SiPMs with a light guide; and the other was a scintillator directly coupled with an array of SiPMs. Among the SiPM-based detectors, the direct coupling system showed the best energy resolution at all energy peaks. It achieved 9.76% energy resolution for a 662 keV gamma ray. Through additional experiments and a simulation, we proved that the light guide degraded energy resolution with increasing statistical uncertainty. The results indicated that the SiPM-based scintillation detector with no light guide is the most efficient design for monitoring radionuclides in an aquatic environment.

얇은 필름 형태의 알파선 측정용 ZnS(Ag) 섬광 검출소재 제조 연구 (Study on preparation of a thin film type of ZnS(Ag) scintillator sheet for alpha-ray detection)

  • 서범경;정연희;김계홍;이근우;정종헌;한명진
    • 분석과학
    • /
    • 제19권5호
    • /
    • pp.389-393
    • /
    • 2006
  • ZnS(Ag) 섬광체와 광전자증배관(PMT)으로 구성된 검출기는 원자력시설에서 알파선 측정용 장치로 많이 사용되고 있다. 이들 검출기는 대부분이 분말 상태의 ZnS(Ag) 섬광체를 투명한 플라스틱 소재 위에 얇게 발라서 제조한다. 본 연구에서는 간단한 방법을 이용하여 ZnS(Ag) 섬광 검출소재를 제조하기 위한 조건을 확립하였다. 검출소재는 지지체 고분자 필름과 ZnS(Ag) 섬광층로 구성된 이중구조로 제조하였으며, 지지체 필름은 고분자 소재를 녹인 후 casting 방법으로 제조하였고, ZnS(Ag) 섬광층은 접착제에 ZnS(Ag) 분말을 첨가하여 screen printing 기법으로 제조하였다. 이와 같은 제조공정을 이용하여 다양한 소재에 대한 평가 결과, 지지체 필름의 고분자 소재로서는 PSf이 가장 우수하였고, 접착제로서는 cyano resin이 가장 적합하다는 것을 확인하였다. 또한, 제조한 섬광 검출소재는 충분한 기계적 강도와 섬광체로서의 우수한 투명도를 가진다는 것을 확인하였으며, 알파선 검출 성능도 확인하였다.

휴대용 검출기의 방사선 고감도 검출을 위한 SiPM 특성 분석 (Characteristics Analysis of SiPM for Detection of High Sensitivity of Portable Detectors)

  • 강병욱;유선국
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.897-902
    • /
    • 2023
  • 본 논문에서는 휴대용 X-ray 검출기의 방사선 고감도 검출에 대한 실현 가능 여부를 확인하기 위한 SiPM의 특성 분석을 목적으로 한다. 휴대용 X-ray 검출기는 환자의 위치에 빠르게 접근하여 실시간 이미지를 획득함으로써 의사들은 신속하게 진단을 수행할 수 있는 장점이 있지만 이러한 이동성은 선량 감지의 어려움을 동반한다. 기존 검출기에서는 SiPM을 X-ray Trigger를 판별하는 단순한 용도로 사용하고 있다. SiPM을 통한 X-ray의 고감도 검출 가능 여부를 확인하기 위해 7종의 SiPM Sensor를 비교 선정하고 특성 분석을 진행하였다. 최종 시험에 사용한 SiPM은 10 nGy 수준의 극저선량 조사 조건에서 Signal 구분이 가능하며, 관전압에 따라 Signal 상승곡선의 기울기가 변하는 것이 확인되었다. X-ray 선량에 따라 SiPM의 signal level 및 지속시간이 변화되는 특성을 이용한 고감도 측정이 가능할 것으로 보인다.

NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰 (Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube)

  • 최용;김종호;김준영;임기천;김상은;최연성;이경한;주관식;김병태
    • 대한핵의학회지
    • /
    • 제34권1호
    • /
    • pp.82-93
    • /
    • 2000
  • 목적: 이 논문에서는 본 연구진이 개발한 소형 감마카메라 시스템에서 사용한 NaI(Tl)섬광결정-위치민감형 광전자증배관 검출기와 각 전자회로에서의 입 출력 신호특성을 조사하고, 시스템 개발을 위해 각 전자회로에서 결정한 변수들에 대하여 고찰하고자 한다. 대상 및 방법: 크기가 $60{\times}60{\times}6mm^3$인 NaI(Tl) 섬광결정을 위치민감형 광전자증배관에 접합하고, 저항 회로와 전치증폭기, 여러 가지 전자회로, 아날로그-디지털 변환기 그리고 개인용 컴퓨터를 이용하여 소형 감마카메라 시스템을 개발하였다. 섬광결정에서 검출된 신호들을 위치민감형 광전자증배관을 통하여 증폭한 후, 전하분할방법으로 34개의 교차된 양극채널 신호를 4개($X^+,\;X^-,\;Y^+,\;Y^-$) 위치신호로 출력시켰다. 출력된 신호를 전치증폭기와 층폭기를 사용하여 증폭 정형하였으며, 핵기기 모듈(nuclear instrument modules, NIMs)을 이용하여 위치신호와 트리거 신호를 처리하였고, 각 단계에서 신호특성을 분석 고찰하였다. 이 신호들을 아날로그-디지털 변환기와 앵거로직을 사용하여 처리한 후, 일반 개인용 컴퓨터에서 그래픽 프로그램을 이용하여 감마카메라 영상을 구현하였다. 결과: 연구에서 분석 고찰한 신호특성을 그림을 통하여 나타내었으며, 이러한 신호처리를 이용하여 개발한 감마카메라는 약 $8{\times}10^3$ counts/sec/${\mu}Ci$의 계수율을 보였다. 140 keV에 대하여 18% FWHM의 에너지 분해능과 X, Y 방향으로 각각 2.2, 2.3 mm FWHM의 내인성 위치 분해능을 나타내었다. 또한 평행구멍형 조준기를 장착한 상태에서 유방모형에 위치한 $2{\sim}7mm$ 직경의 방사능 분포를 정확하게 영상화할 수 있었다. 결론: 이 연구에서 개발한 소형 감마카메라 시스템을 구성하고 있는 각 전자회로에서 결정한 매개변수와 신호특성 고찰결과를 나타내었다. 이 신호처리 시스템 분석을 통하여 감마선 검출을 이용한 영상표현 기술을 확보할 수 있었으며, 소형 감마카메라 개발을 위한 간단한 신호처리 방법을 고안하여 제시하였다.

  • PDF

다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발 (Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube)

  • 권순일;홍성종;이또우 미끼꼬;윤현석;이건송;심광숙;이준택;이동수;이재성
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.469-477
    • /
    • 2008
  • 목적: 소동물용 PET은 우수한 공간분해 능과, 민감도가 요구된다. 본 연구에서는 256개의 개별적 채널을 4개로 줄여 검출위치를 추정할 수 있는 회로를 설계하고 제작하였으며, 256($16{\times}16$)개의 양극 출력 채널을 가지는 고집적도의 광전자증배관 및 $L_{0.9}GSO$ 섬광결정과 결합하여 그 성능을 검증하였다. 대상 및 방법: 설계한 회로를 제작하기에 맞서 전자회로 시뮬레이션을 통해 성능을 예상하였다. 회로의 검증과 성능분석을 위하여 위치결정회로, H9500(Hamamatsu Photorucs K.K., 일본) 광전자증배관, $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ 섬광결정으로 두 개의 검출단을 제작하고 $3.7{\times}10^5$ Bq의 $^{22}Na$ 방사선원을 사용하여 동시이벤트를 검출하였다. 첫 번째 검출단은 $L_{0.9}GSO\;29{\times}29$ 섬광결정블록을 단층으로 구성하였고, 두 번째 검출단은 $L_{0.9}GSO\;29{\times}29$$28{\times}28$ 섬광결정블록을 x와 y방향으로 각각 섬광결정 단면 길이의 반만큼 오프셋을 두어 접합하였다. 또한 측정된 데이터를 실제 섬광결정 영역으로 보정하기 위하여 섬광결정지도를 구했다. 결과: 평면영상을 통해 각 섬광결정들이 잘 구분되는 것을 확인할 수 있었고, 회로 개선 후 주변부의 섬광결정들이 마지막 줄까지 명백히 구분되었다. 각 섬광결정들의 에너지 분해능은 11.6%(표준편차 1.6)이었다. 결론: 본 연구에서 제안한 위치결정회로는 실험을 통해 소동물용 PET개발에 있어 만족할만한 성능을 보여주었다. 향후 더욱 정밀한 시스템을 제작하기 위해서는 다중양극 광전자증배관의 이득 불균일을 보정하기 위한 연구가 진행되어야 할 것이다.

형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석 (Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter)

  • 오상우;서동민;안기영;김재우;이문진;전태병;서성규
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권4호
    • /
    • pp.304-309
    • /
    • 2015
  • 해양에서 기름 유출 사고로 인한 오염도를 정량적으로 평가하기 위해서, 사고 현장에서 기름을 직접 탐지할 수 있는 센서의 적용이 필요하다. 여러 형태의 기름 탐지 센서 중에서, 기름 성분에 의한 형광 현상(fluorescence)을 탐지 원리로 하는 센서는 해수 중에 존재하는 기름의 농도를 측정할 수 있으므로 효용성이 높은 장점을 갖고 있다. 그러나 이런 종류의 센서는 기름의 형광 현상을 야기시키기 위해서, 수은 램프(mercury lamp)와 같은 자외선 광원(ultraviolet light source)이 필요하고 다양한 종류의 광학 필터와 광전증배관(photomultiplier tube, PMT)과 같은 광학 센서가 주로 사용된다. 이러한 이유로 형광 측정을 기반으로 하고 있는 센서는 측정 플랫폼의 크기가 크기 때문에 현장에서 원활히 사용하기에 한계가 있으며, 고가의 부품들이 집적되어 있어, 센서의 가격이 높은 단점을 갖고 있다. 이러한 단점을 극복하기 위해서, 본 논문에서는 소형의 크기와 가격 경쟁력을 갖고 있는 형광 광도계 기반의 기름 탐지 센서를 설계하는 방법에 대해서 제시하였다. 형광 광도계의 설계 인자를 파악하기 위한 방법으로, 본 연구에서는 5종의 원유 샘플과 3종의 정제유를 이용하여, 기름의 여기 스펙트럼(excitation spectrum)과 발광 스펙트럼(emission spectrum)을 측정하였다. 여기 스펙트럼과 발광 스펙트럼의 측정을 위해서는 형광 분광기(fluorescence spectrometer)를 이용하였고, 측정된 스펙트럼 자료를 분석하여 형광 광도계(fluorimeter) 설계에 필요한 유종에 따른 공통 스펙트럼 파장 대역을 도출하였다. 본 실험을 통해서 모든 종류의 기름 샘플의 경우, 여기 스펙트럼과 발광 스펙트럼의 최고 값을 갖는 파장의 차이는 약 50 nm인 것으로 파악되었다. 실험 중에서, 여기광의 파장을 365 nm와 405 nm로 고정하였을 경우, 280 nm와 325 nm로 고정하였을 경우에 비해서 최대 발광(emission)의 세기가 작아지는 것을 확인할 수 있었다. 따라서 형광 광도계의 광원 파장을 365 nm 또는 405 nm로 사용할 경우, 광학 센서의 민감도(sensitivity)가 발광되는 빛의 세기를 측정할 수 있도록 설계에 반영해야 할 것으로 판단된다. 본 연구의 실험에서 도출된 결과를 통해서, 기름 탐지를 위한 형광 광도계의 광원, 광학 센서 그리고 광학 필터의 유효 파장 대역을 선택하는데 필요한 설계 인자를 파악할 수 있었다.