• Title/Summary/Keyword: Photomultiplier tube

Search Result 59, Processing Time 0.024 seconds

Development of Prototype Liquid Scintillator System for Monitoring Liquid Radioactive Waste (배수 모니터링 액체섬광검출시스템의 프로토 타입 개발)

  • Nam, Uk-Won;Seon, Kwang-Il;Kong, Kyoung-Nam;Kim, Chang-Kyu;Lee, Dong-Myung;Lee, Sang-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.173-182
    • /
    • 2003
  • A prototype liquid scillatillator system for measurement of multiple beta-labeled mixtures was developed and its characteristic was investigated. The signal processing system consists of two photomultiplier tubes and the coincident count circuit. The characteristic of the system was analyzed using 4 beta-labeled samples $(^3H,\;^{14}C,\;^{36}Cl\;and\;^{90}Sr)$. Beta spectra from the samples were obtained without radiation shielding, and the detection limits for each nuclides were estimated based on the spectra. The estimated detection limits were compared to the legal regulation values. It is found that the liquid radioactive nuclides are detectable well below the legal regulation values.

Simulation of a neutron imaging detector prototype based on SiPM array readout

  • Mengjiao Tang;Lianjun Zhang;Bin Tang;Gaokui He;Chang Huang;Jiangbin Zhao;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3133-3139
    • /
    • 2023
  • Neutron imaging technology as a means of non-destructive detection of materials is complementary to X-ray imaging. Silicon photomultiplier (SiPM), a new type of optical readout device, has overcome some shortcomings of traditional photomultiplier tube (PMT), such as high-power consumption, large volume, high price, uneven gain response, and inability to work in strong magnetic fields. Its application in the field of neutron detection will be an irresistible general trend. In this paper, a thermal neutron imaging detector based on 6LiF/ZnS scintillation screen and SiPM array readout was developed. The design of the detector geometry was optimized by geant4 Monte Carlo simulation software. The optimized detector was evaluated with a step wedge sample. The results show that the detector prototype with a 48 mm × 48 mm sensitive area can achieve about 38% detection efficiency and 0.26 mm position resolution when using a 300 ㎛ thick 6LiF/ZnS scintillation screen and a 2 mm thick Bk7 optical guide coupled with SiPM array, and has good neutron imaging capability. It provides effective data support for developing high-performance imaging detectors applied to the China Spallation Neutron Source (CSNS).

Characteristics of lightning impulse breakdowns in inhomogeneous $SF_6$ gas gap (불평등전장에서 $SF_6$ 기체의 뇌임펄스 절연파괴특성)

  • Lee, B.H.;Choi, H.S.;Oh, S.K.;Li, F.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1921-1923
    • /
    • 2004
  • V-p characteristics and the discharge luminous characteristics in inhomogeneous $SF_6$ gas gap under the positive and negative lightning impulse voltages are presented. The test gap was composed of the plane-to-plane with a needle-shaped protrusion. The applied voltage and the predischarge current were measured by the electric field sensor and the shunt of 50 ${\Omega}$, respectively. The light emission signals were observed by a photomultiplier tube, and a high-speed camera. In a consequence, the dielectric strengths of $SF_6$ gas gap under positive lightning impulse voltages were independent of the gas pressure. In the presence of the positive polarity, the branches of discharge channel were created and the directions of the discharge paths were random. On the other hands, the discharge paths of the negative polarity were more thicker and brighter.

  • PDF

Design of Photoelectric Photometer using Operational Amplifier (연산증폭기에 의한 광전측광장치의 설계)

  • 노홍조;김동진
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.4
    • /
    • pp.7-16
    • /
    • 1972
  • A prototype of photoelectric photometer has been developed by all solid state operational amplifiers. The amplification of low-level anode currents from photomultiplier tube corresponding to a given incident light intensity and logarithmic transfer for star's magnitude nleasurements are achieved by the same operational amplifier. It is important to select low input bias currents for stable performance because the resolution is primarily limited by the bias currents. As such, they offer a higher reliable and economical for a large number of electrometer amplifier applications which have traditionaly been fulfilled by vacuum electrometer tubes or vibrating reed electrometers.

  • PDF

Light Scattering Characteristics of Defects on Silicon Wafer Surface (실리콘 웨이퍼 미세 표면결함의 광산란 특성 평가)

  • Ha T.H.;Song J.Y.;Miyoshi Takashi;Takaya Yasuhiro
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1083-1086
    • /
    • 2005
  • Light scattering measurement system that can evaluate light scattering characteristic from defects on silicon wafer surface has been developed. The system uses $Ar^+$ laser as an illumination source, and a highly sensitive photomultiplier tube (PMT) for detecting scattered light from defects. Unlike with conventional measurement system, our system has ability to measure scattered light pattern from wide range of scattering angles with changeable incidence condition. It is shown that our developed system is effective to discriminate the types and sizes of defects from basic experimental results using a microscatch and a PSL sphere.

  • PDF

Operating Characteristics of a Time-Correlated Single Photon Counting System and its Application to Fluorescence Life Time Measurements (시간 상관 단일 광자 계수기의 동작 특성과 형광 수명 시간 측정에의 응용)

  • Ko, D.S.;Jung, H.S.;Kim, U.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.512-514
    • /
    • 1989
  • A time-correlated single photon counting system combined with a mode locked $Ar^+$ laser has been utilized to measure the fluorescence decay. A side-on type photomultiplier tube has been used as a photon detector. By restricting the sensitive area and the position of the photocathode, the transit time differencies of photoelectrons in PMT has been reduced. The fluorescence life time of rhodamin 6G in ethylene glycol measured 3.9$\pm$10 ns.

  • PDF

Assessment of a Phase Doppler Anemometry Technique in Dense Droplet Laden Jet

  • Koo, Ja-Ye;Kim, Jong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.7
    • /
    • pp.1083-1094
    • /
    • 2003
  • This study represents an assessment of the phase-Doppler technique to the measurements of dense droplet laden jet. High-pressure injection fuel sprays have been investigated to evaluate the use of the Phase-Doppler anemometry (PDA) technique. The critical issue is the stability of the phase-Doppler anemometry technique for dense droplet laden jet such as Diesel fuel spray in order to insure the results from the drop size and velocity measurements are repeatable, consistent, and physically realistic because the validation rate of experimental data is very low due to the thick optical density. The effect of shift frequency is minor, however, the photomultiplier tube (PMT) voltage setting is very sensitive to the data acquisition and noise in dense droplet laden jet. The optimum PMT voltage and shift frequency should be chosen so that the data such as volume flux and drop diameter do not change rapidly.

Next Generation PET for Human Brain Study

  • Murayama, Hideo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.35-37
    • /
    • 2002
  • Conceptual design of the next generation PET with both high sensitivity and high spatial resolution has been performed. A detector unit using a depth encoding scheme was designed and constructed for trial. The unit consists of four Gd$_2$SiO$\sub$5/:Ce crystal blocks in a 2x2x4 array coupled to a position-sensitive photomultiplier tube having metal channel dynodes and 4x4 multi-anodes. Our proposed detector is a very reliable and simple solution suitable for volume PET devices since the proposed depth encoding scheme does not need additional photo-detectors.

  • PDF

An Experimental Study on Chemiluminescence Characteristics of a Turbulent Flame (난류화염의 화학적 발광 특성에 관한 실험적 연구)

  • Kwon, Minjun;Kim, Sewon;Lee, Changyeop;Kim, Yongmo
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.4
    • /
    • pp.1-9
    • /
    • 2015
  • The object of this study is a deriving the relations according to the measuring locations between the chemiluminescence and the flame state at commercial burner. In this study, the flame chemiluminescence of the flame of commercial burner is measured using a photomultiplier tube and the optical band-pass filter. In addition, the contour of the chemiluminescence of the flame is measured using the common CCD camera and the optical band-pass filters, and the acquired images is converted by the simple image processing as a matrix form. The results showed that certain relationship between optical data and equivalence ratio exists, and the contour according to the measuring location of the flame chemiluminescence is different by equivalence ratio.

A Study on the Secondary Electron Detector for use in Scanning Electron Microscope (SEM용 전자 검출기의 설계 및 제작)

  • Lee SangUk;Jeon Jong Up;Park KiTae;Park Kyu Yeol
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.9-14
    • /
    • 2005
  • The nature of the signals collected by an SEM(Scanning Electron Microscope) in order to form images are all dependent on the detector used to collect them, and the quality of an acquired image is strongly influenced by detector performance. Therefore, the development of detector with high performance is very important in pulling up the resolution of SEM This study presents the secondary electron detector for use in scanning electron microscope, electric circuit and I/V conversion circuit for driving that detector.

  • PDF