• 제목/요약/키워드: Photometric Calibration

검색결과 45건 처리시간 0.028초

SNU AGN Monitoring Project (SAMP) using reverberation mapping of luminous AGNs

  • Jeon, Yiseul;Woo, Jong-Hak
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.70.4-71
    • /
    • 2016
  • The links between super-massive black hole masses and their host galaxy properties are observed, indicating that black hole growth and host galaxy evolution are closely related. Reverberation mapping, which uses the time delay from the central black hole to broad line regions, is one of the best methods to estimate masses of black holes of active galactic nuclei (AGNs). However, only masses of about 50 black holes have been determined in reverberation mapping studies so far, and most of them are limited to optical luminosities below 10^45 erg/s due to the challenges of long-term time domain observations in both photometry and spectroscopy. In this project, we expand reverberation mapping samples to higher luminosities of > 10^44.5 erg/s at 0.1 < z < 0.35, that have expected time lags of 40 - 250 light days. Photometric (using LOAO 1-m and MDM 1.3-m) and spectroscopic (using MDM 2.4-m and Lick 3-m) monitoring campaigns are being conducted for a 3 year duration and 20 day cadence. Precedent photometric observations in 2015B show some targets with variability and follow-up spectroscopic observations are on-going. In this presentation, we introduce our project, present reverberation mapping simulation results, and preliminary results on photometry. These reverberation mapping masses of relatively high luminous AGNs will provide a strong constraint on black hole mass calibration, e.g., the single-epoch mass estimation.

  • PDF

Determination of florfenicol residues in swine tissues using high-performance liquid chromatography with ultraviolet photometric detector

  • Chae, Won-Seok;Yoo, Chang-Yeul;Tutkun, Lutfiye;Kim, Suk;Lee, Hu-Jang
    • Journal of Preventive Veterinary Medicine
    • /
    • 제42권4호
    • /
    • pp.171-176
    • /
    • 2018
  • A study of the tissue depletion of florfenicol (FFC) administered orally to pigs at a dose of 0.05 kg/ton feed for 7 days was performed. Sixteen healthy cross swine were administered with FFC. Four treated animals were arbitrarily selected to be sacrificed 1, 3 and 5 days after the end of treatment. FFC residue concentrations in muscle, liver, kidney, and fat were determined using high-performance liquid chromatography (HPLC) with ultraviolet photometric detector at 230 nm. The correlation coefficient ($R^2$) of the calibration curve for florfenicol amine (FFCa) was > 0.997 and the limits of detection and quantification were 0.012 and $0.040{\mu}g/mL$, respectively. Recovery rates in swine edible tissues ranged from 79.1 to 93.5%. In the FFC-treated group, FFC residues at 3 days post-treatment were below the maximum residue limits (MRLs) in muscle, kidney and fat, and those at 5 days post-administration were below the MRLs in all edible tissues. These results suggest that the withdrawal period of FFC after the drug treatment might be 5 days, which is a sufficient amount of time for reduction of the FFC residues below the MRLs in all edible tissues.

NEW PHOTOMETRIC PIPELINE TO EXPLORE TEMPORAL AND SPATIAL VARIABILITY WITH KMTNET DEEP-SOUTH OBSERVATIONS

  • Chang, Seo-Won;Byun, Yong-Ik;Shin, Min-Su;Yi, Hahn;Kim, Myung-Jin;Moon, Hong-Kyu;Choi, Young-Jun;Cha, Sang-Mok;Lee, Yongseok
    • 천문학회지
    • /
    • 제51권5호
    • /
    • pp.129-142
    • /
    • 2018
  • The DEEP-South (the Deep Ecliptic Patrol of the Southern Sky) photometric census of small Solar System bodies produces massive time-series data of variable, transient or moving objects as a by-product. To fully investigate unexplored variable phenomena, we present an application of multi-aperture photometry and FastBit indexing techniques for faster access to a portion of the DEEP-South year-one data. Our new pipeline is designed to perform automated point source detection, robust high-precision photometry and calibration of non-crowded fields which have overlap with previously surveyed areas. In this paper, we show some examples of catalog-based variability searches to find new variable stars and to recover targeted asteroids. We discover 21 new periodic variables with period ranging between 0.1 and 31 days, including four eclipsing binary systems (detached, over-contact, and ellipsoidal variables), one white dwarf/M dwarf pair candidate, and rotating variable stars. We also recover astrometry (< ${\pm}1-2$ arcsec level accuracy) and photometry of two targeted near-earth asteroids, 2006 DZ169 and 1996 SK, along with the small- (~0.12 mag) and relatively large-amplitude (~0.5 mag) variations of their dominant rotational signals in R-band.

환원 황화합물의 열탈착 분석기법에 대한 감도의 경시변화 및 재현성에 대한 연구 (Examination of GC-TD sensitivity for reduced sulfur compounds in relation to temporal stability and reproducibility)

  • 홍원필;김기현
    • 분석과학
    • /
    • 제23권1호
    • /
    • pp.24-35
    • /
    • 2010
  • 본 연구에서는 GC-PFPD와 열탈착 분석기법을 이용한 환원 황화합물(reduced sulfur compounds: RSC)에 대한 열탈착 검량방식의 시간적 재현성을 기존의 외부 검량기법에 덧붙여, 내부표준시료 기법을 연계하여 평가하고자 하였다. 이를 위하여, 4종류의 악취성 황화합물질($H_2S$, $CH_3SH$, DMS, DMDS)과 이들에 대한 내부 표준시료로 CS2를 준비하였다. 이들 표준시료는 저농도(10, 20, 50, 100 ppb)와 고농도 그룹(100, 200, 500, 1000 ppb)을 대표할 수 있게 넓은 범위로 준비하였다. 그리고 외부검량(external calibration)방식의 분석 결과를 부피고정방식(fixed standard volume: FSV)과 농도고정방식(fixed standard concentration: FSC)로 비교하였다. 또한, 2차적으로 FSV 방식의 결과에 외부 및 내부 검량기법을 동시에 적용하여 검량방식의 경시변화(안정도)를 평가하였다. 본 실험의 결과, 감도에 대한 경시변화는 FSC 방식에 비해 FSV 방식에서 작게 나타났다. 따라서 RSC 분석에서 FSV방식이 경시변화를 줄여주는데 상대적으로 효과적이라는 것을 알 수 있었다. 2차적으로 FSV 방식의 결과에 대해 외부 및 내부방식의 감도(기울기 값)를 비교하였다. 이러한 비교를 상대표준편차(RSD)값으로 평가하면, GC-PFPD-TD 시스템의 감도가 비교적 강한 경시변화를 보인다는 것을 알 수 있다. 따라서 이러한 분석기법의 시간적 재현성을 확보하기 위해서는 여러 가지 검정노력이 필요한 것으로 사료된다.

On the Optical Characteristics of Solar X-Ray Telescopes: Possible Relation between Vignetting Effect and Mirror Scattering

  • Shin, Jun-Ho;Sakurai, Takashi
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • Since early 90's, the solar X-ray telescopes such as Yohkoh SXT and Hinode XRT have observed coronal magnetic structures on the Sun's surface in the range of about $40'{\times}40'$ field-of-view (FOV) covering the full solar disk. Thus it has been stressed by the scientists that the optical structure of solar telescopes should be designed with care for improving the uniformity over a wide FOV. There would be, however, no unique solution in designing the optical system of a telescope for overcoming perfectly the problem of off-axis response variation. As a consequence, the correction of optical imperfectness of telescopes has become an important calibration step that should be performed beforehand when the observed images are to be used for photometric purposes. In particular, a special care should be taken when performing the temperature analysis with thin and thick filters for flaring activities observed at the periphery of the full FOV. From the analyses of both pre-launch calibration and in-flight observation data, the optical characteristics for describing the performance of solar X-ray telescopes, especially in view of their energy dependence, will be introduced and discussed in our presentation.

  • PDF

COLOR EXCESSES AND PERIOD-COLOR RELATION OF CLASSICAL CEPHEIDS

  • Kim, Chul-Hee;Moon, B.K.;Yushchenko, A.V.
    • 천문학회지
    • /
    • 제43권5호
    • /
    • pp.153-159
    • /
    • 2010
  • Color excesses of classical Cepheids in the uvby color system are estimated for the calibration stars with distances from the literature that are measured independently. Intrinsic photometric indices for these stars are calculated and a calibrated empirical relation between (b - y)$_0$, period, [$c_1$], and [$m_1$] is derived through a linear fit. This relation is used to determine color excesses E(b-y) for 59 Cepheids. We also examine the period-color [log P : (b - y)$_0$] relation, and find no signs of nonlinearity. We estimate the effective temperature and surface gravity of several Cepheids using both Kurucz and MARCS/SSG grids for [Fe=H]=0.0. We confirm that both temperature and surface gravity are higher, by about 150K and 0.4 respectively, when the MARCS/SSG atmospheric grids are used.

REDUCING X-ray BRIGHT GALAXY GROUPS IMAGES WITH THELI PIPELINE

  • NIKAKHTAR, FARNIK
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.671-673
    • /
    • 2015
  • Before analyzing the images taken with a Mosaic CCD imager, the images have to reach a state which can be used for further scientific analysis. The transformation of raw images into calibrated images is called data reduction. Transforming HEavely Light into Images (THELI) is a nearly fully automated reduction pipeline software (Erben et al., 2005). This pipeline works on raw images to remove instrumental signatures, mask unwanted signals, and perform photometric and astrometric calibration. Finally THELI constructs a deep co-added mosaic image and a weight map. In this poster, THELI data reduction procedures will be reviewed and the reduction process for raw images of seven X-ray bright groups, extracted from GEMS groups (Osmond & Ponman, 2004) obtained by the Wide Field Imager (WFI) mounted on MPG/ESO telescope at La Silla in March 2006 will be discussed.

The Performance of Flight Model of the NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Moon, Bongkon;Park, Sung-Joon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Won-Kee;Kim, Il-Joong;Park, Youngsik;Ko, Kyeongyeon;Kim, Mingyu;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.58.1-58.1
    • /
    • 2017
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) is the near-infrared spectro-photometric instrument optimized to the first Next Generation of small satellite (NEXTSat-1). The off-axis optics was developed to cover a wide field of view with 2 deg. ${\times}$ 2 deg. as well as a wide wavelength range from 0.95 to $2.5{\mu}m$. Considering the simple alignment scheme, afocal system was adapted in the optical components. The mechanical structures were tested under the space environment. We have obtained the accurate calibration data using our test facilities under the operational condition. After the final integration of flight model into the satellite, the communication with the satellite and the functional test were passed. The NISS will be launched in early 2018. During around 2-year operation, the spectro-photometric survey covering more than 100 square degree will be performed. To achieve the major scientific objectives for the study of the cosmic star formation in local and distant universe, the main observational targets will be nearby galaxies, galaxy clusters, star-forming regions and low background regions. Here, we report the final performance of the flight model of the NISS.

  • PDF

STANDARDISATION OF NIR INSTRUMENTS, INFLUENCE OF THE CALIBRATION METHODS AND THE SIZE OF THE CLONING SET

  • Dardenne, Pierre;Cowe, Ian-A.;Berzaghi, Paolo;Flinn, Peter-C.;Lagerholm, Martin;Shenk, John-S.;Westerhaus, Mark-O.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1121-1121
    • /
    • 2001
  • A previous study (Berzaghi et al., 2001) evaluated the performance of 3 calibration methods, modified partial least squares (MPLS), local PLS (LOCAL) and artificial neural networks (ANN) on the prediction of the chemical composition of forages, using a large NIR database. The study used forage samples (n=25,977) from Australia, Europe (Belgium, Germany, Italy and Sweden) and North America (Canada and U.S.A) with reference values for moisture, crude protein and neutral detergent fibre content. The spectra of the samples were collected using 10 different Foss NIR Systems instruments, only some of which had been standardized to one master instrument. The aim of the present study was to evaluate the behaviour of these different calibration methods when predicting the same samples measured on different instruments. Twenty-two sealed samples of different kind of forages were measured in duplicate on seven instruments (one master and six slaves). Three sets of near infrared spectra (1100 to 2500nm) were created. The first set consisted of the spectra in their original form (unstandardized); the second set was created using a single sample standardization (Clone1); the third was created using a multiple sample procedure (Clone6). WinISI software (Infrasoft International Inc., Port Mathilda, PA, USA) was used to perform both types of standardization, Clone1 is just a photometric offset between a “master” instrument and the “slave” instrument. Clone6 modifies both the X-axis through a wavelength adjustment and the Y-axis through a simple regression wavelength by wavelength. The Clone1 procedure used one sample spectrally close to the centre of the population. The six samples used in Clone 6 were selected to cover the range of spectral variation in the sample set. The remaining fifteen samples were used to evaluate the performances of the different models. The predicted values for dry matter, protein and neutral detergent fibre from the master Instrument were considered as “reference Y values” when computing the statistics RMSEP, SEPC, R, Bias, Slope, mean GH (global Mahalanobis distance) and mean NH (neighbourhood Mahalanobis distance) for the 6 slave instruments. From the results we conclude that i) all the calibration techniques gave satisfactory results after standardization. Without standardization the predicted data from the slaves would have required slope and bias correction to produce acceptable statistics. ii) Standardization reduced the errors for all calibration methods and parameters tested, reducing not only systematic biases but also random errors. iii) Standardization removed slope effects that were significantly different from 1.0 in most of the cases. iv) Clone1 and Clone6 gave similar results except for NDF where Clone6 gave better RMSEP values than Clone1. v) GH and NH were reduced by half even with very large data sets including unstandardized spectra.

  • PDF

투명 e-퍼포먼스를 위한 텍스쳐 중화 시스템 개발 (Development of Texture Neutralization System for the Invisible e-Performance)

  • 이동훈;윤태수
    • 한국멀티미디어학회논문지
    • /
    • 제14권4호
    • /
    • pp.585-594
    • /
    • 2011
  • 연극이나 뮤지컬과 같은 라이브 퍼포먼스 분야에서는 관객의 몰입도를 극대화하기 위한 다양한 무대 효과가 사용된다. 이러한 무대 효과는 전통적인 연출 기법으로부터 장면에 몰입을 줄 수 있는 다양한 무대 효과를 위한 장치들을 활용하고 있다. 본 논문에서는 공간증강현실 기반의 사물의 표면 텍스쳐를 제어할 수 있는 새로운 디지털 시각 효과를 제안한다. 이를 위하여 프로젝터-카메라 시스템을 사용하여 임의의 물체의 표면을 중화할 수 있는 방법을 제시한다. 객체의 표면에 신중하게 결정된 보상 영상(Compensation Image)을 투영함으로써 투명한 객체처럼 나타나도록 만들기 위해, 본 논문에서는 간단하고 효과적인 오프라인 프로젝터-카메라 보정을 위한 호모그래피 방법(Homography Method)를 사용한다. 따라서 제안하는 Radiometric 매개 변수를 측정하기 위한 스마트 프로젝터(Smart Projector)의 기본 알고리즘은 연극이나 뮤지컬에서의 시간적 변화에 유용하게 사용될 것이다.