• Title/Summary/Keyword: Photo sensors

Search Result 166, Processing Time 0.026 seconds

A Quasi-Distributed Fiber-Optic Sensor System using an InGaAs PD Array and FBG Sensors for the Safety Monitoring of Electric Power Systems (InGaAs PD 어레이와 광섬유 격자를 이용한 준분배형 전력설비 안전진단 시스템)

  • Kim, Hyun-Jin;Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.86-91
    • /
    • 2010
  • We constructed a quasi-distributed fiber-optic sensor network for the safety monitoring in power systems. It is possible to construct many of FBG sensors in a line and to be immune from electromagnetic noise. For demodulation analysis of reflected wavelength from FBG sensor, we proposed a simple and fast system using a InGaAs photo-diode array and a holographic diffraction grating. For accuracy improvement of the proposed demodulation system, we applied a Gaussian line-fitting algorithm. We obtained about 4[pm] of wavelength resolution and stability.

Hardware implementation of a CMOS image sensor pixel using complemental signal path (상보형 신호경로 방식의 CMOS 이미지 센서 픽셀의 하드웨어 구현)

  • Jung, Jin-Woo;Kwon, Bo-Min;Kim, Ji-Man;Park, Ju-Hong;Park, Yong-Su;Lee, Je-Won;Song, Han-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.475-484
    • /
    • 2009
  • In this paper, an analysis of the complementary CMOS active pixel and readout circuit is carried out. Complementary pixel structure which is different from conventional 3TR APS structure consists of photo diode, reset PMOS, several NMOSs and PMOSs sets for complementary signals. Proposed CMOS image sensors pixel has been fabricated using 0.5 standard CMOS process. Measured results show that the output signal range is from 0.8 V to 3.8 V. This output signal range increased 125 % compared to conventional 3TR pixel in the condition of 5 V power supply.

Development of a Device for Estimating the Optimal Artificial Insemination Time of Individually Stalled Sows Using Direct-reflex Photo-sensors (직접반사형 포토센서를 이용한 스톨 사육 모돈의 인공수정적기 예측 장치 개발)

  • Kim D. J.;Yeon S. C.;Chang H. H.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.6 s.107
    • /
    • pp.515-520
    • /
    • 2004
  • A device far estimating the optimal artificial insemination time consisted of a computer, RS module, and six direct-reflex photo-sensors. Program was written in LabWindows CVI. In order to establish references for estimating optimal artificial insemination time, lying rate of the thirty three $Berkshire{\times}Hampshire crossbred sows (parity 5 to 6) was recorded from 2 days after moving into stalls to artificial insemination using a time lapse VCR and was measured every hour with one minute interval using the scan point sampling method. Twenty low hours in a day were divided into three comparing periods : 21:00 to 06:59, 07:00 to 13:59, and 14:00 to 20:59. If sum of the percentages of tying during a comparing period was less than the reference value, the starting hour of the comparing period was considered as onset of estrus and the optimal artificial insemination time was estimated at 20 to 24 hours after onset of estrus. The experimental device was evaluated with twenty five $Berkshire{\times}Hampshire$ crossbred sows (parity 2 to 7) and 23 of 25 sows $(92\%)$ were pregnant. This result suggests that the experimental device is excellent in performance for estimating optimal artificial insemination time.

Development of multi-colorimeter module for low-cost urinalysis strip readers (저가형 요분석 시스템의 다중 광 검출 모듈개발)

  • Ye, Soo-Young;Jeon, Yong-Uk;Jeong, Do-Un;Jeon, Gye-Rok;Ro, Jung-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.387-395
    • /
    • 2008
  • An optic module system is developed adopting multiple colorimetry units for the measurement of multi-pad urinalysis dipsticks. Multiple photometry system instead of moving mechanisms has the advantages of system reliability and simplicity as well as economic aspects due to the recent development of economic color light emitting diodes and stable photo sensors. An integration amplifier with programmable integration time, a current source circuit with selectable and stable current settings were connected through analog multiplexers to thirty light emitting diodes for illumination and ten photo transistors for reading each strip pad. All the circuits are controlled by a microprocessor through a simple set of serial communication commands. The detect ability is eighteen times better than the minimum color difference of the test grading which is 0.013 in urobilinogen in the color space defined in this paper.

The development of radiation lifetime measuring module for KAEROT/m2 (KAEROT/m2용 방사선 수명 측정모듈 개발)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.793-796
    • /
    • 2003
  • The electronics of a mobile robot ill nuclear facilities is required to satisfied the reliability to sustain survival in its radiation environment. To know how much radiation the robot has been encountered to replace sensitive electronic parts, a dosimeter to measure total accumulated dose is necessary. Among many radiation dosimeters or detectors, semiconductor radiation sensors have advantages in terms of power requirements and their sires over conventional detectors. This paper describes the use of the radiation-induced threshold voltage change of a commercial power pMOSFET as an accumulated radiation dose monitoring mean and that of the photo-current of a commercial PIN Diode as a dose-rate measurement mean. Commercial p-type power MOSFETs and PIN Diodes were tested in a Co-60 gamma irradiation facility to see their capabilities as radiation sensors. We found an inexpensive commercial power pMOSFET that shows good linearity in their threshold voltage shift with radiation dose and a PIN diode that shows good linearity in its photo-current change with dose-rate. According to these findings, a radiation hardened hybrid electronic radiation dosimeter for nuclear robots has been developed for the first time. This small hybrid dosimeter has also an advantage in the point of view of reliability improvement by using a diversity concept.

  • PDF

Demodulation of FBG and Acoustic Sensors Embedded in a Fiber-Optic Sagnac Loop (광섬유 사낙간섭계에 삽입된 광섬유격자센서와 음향센서의 복조)

  • Kim, Hyun-Jin;Lee, June-Ho;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.44-50
    • /
    • 2012
  • When the fiber Bragg gratings are embedded in a fiber-optic Sagnac loop for measuring temperature or strain, it is difficult to separate the Bragg wavelengths. The transmitted light is mixed with the reflected Bragg wavelengths in the photo-detector, working as noises. To suppress the noises, we placed the FBG sensors and a fiber-optic attenuator at asymmetric positions in the loop. With the arrangement the reflected light became much bigger than the transmitted light, enabling the separation of the reflected Bragg wavelengths with almost the same signal-to-noise ratio of the FBG sensors outside the loop.

Drive of Single-phase Switched Reluctance Motors Using Search Coils (서치코일을 이용한 단상 SRM의 구동)

  • Shin, D.S.;Yang, H.Y.;Lim, Y.C.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.750-753
    • /
    • 2005
  • This paper presents a method of detecting rotor position for single phase Switched Reluctance Motors(SRMs) using searchs coil. In the single phase SRM, mainly Hall effect sensors or photo interrupters have been used to detect the rotor position. But these sensors cause high cost and increase the volume of the motor, Furthermore when the motor is used in very hostile environment like high temperature or pressure, its reliability goes down. In this paper, low cost and robust characteristics of rotor position detection method are focused in order to compensate for disadvantage of existing sensors. Search coils wound around the stator pole are used for detection of the rotor position in single phase SRM. Rotor position detection is achieved through electromotive force patterns induced by time-varying flux linkage in the search coil. The validity of the method is verified by experimental results.

  • PDF

A New Antistiction Method Using Polymer Suspension for Fabrication with Polysilicon Micromachining (다결정 실리콘 마이크로머시닝 제작 시 폴리머 지지를 이용한 옆 방향 정착방지 방법의 제안)

  • Lim, Hyung-Taek;Yoon, Choong-Hyun;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3331-3333
    • /
    • 1999
  • A novel antistiction method using photo resist is proposed and verified to improve the yield of polysilicon micromachining process. $7.5{\mu}m-thick$ polysilicon is used as a structural layer. Residual stress and stress gradient originated from polysilicon deposition with LPCVD process is relaxed by doping and thermal treatment. The stress gradient of stress-free polysilicon layer is $-0.755MPa/{\mu}m$.

  • PDF

Micro toluene gas sensor of SWNTs-PtOx system using the vacuum filtering deposition method (진공여과증착법을 이용한 SWNT-PtOx계 마이크로 톨루엔 가스센서)

  • Kim, Il-Jin;Jeon, Young-Zip;Choi, Chang-Kyu;Lee, Young-Uk;Choi, Si-Young;Han, Chang-Soo;Han, Sang-Do
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.179-183
    • /
    • 2009
  • Toluene($C_6H_5CH_3$) gas sensors were fabricated using $PtO_x$ loaded with SWNTs by a new deposition method. The nanoparticle powders of SWNTs-$PtO_x$ composite were deposited on Si wafer substrates by a vacuum filtering deposition method. The fabricated sensors were tested against toluene gas which is a kind of the Volatile Organic Compounds. The composition ratio that exhibited the highest response to toluene gases was SWNTs : $PtO_x\;=\;99:1$ in wt% ratio at operating temperature of about $150^{\circ}C$. The response and recovery times of the sensors were as short as less than 1 min., respectively.