• 제목/요약/키워드: Phosphate coating

검색결과 126건 처리시간 0.026초

다양한 양극산화막 처리방법이 임프란트 골유착에 미치는 영향 (EFFECT OF VARIOUS INODIZING CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANT SURFACE DESIGN)

  • 차수련;이준;민승기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권5호
    • /
    • pp.417-427
    • /
    • 2008
  • The aim of this study is to investigate the effect of anodizing surface to osseointegration of implant by using of resonance frequency analysis (RFA), quantitative and qualitative assessment of an anodically modified implant type with regard to osseous healing qualities. A total of 96 screw-shaped implants were prepared for this study. 72 implants were prepared by electrochemical oxidation with different ways. 24 (group 1 SP) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid. 24 (group 2GC) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate and 24 (group 3 CMP (Calcium Metaphosphate) Coating were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by CMP coating. Rest of 24 (control group were as a control group of RBM surface. Bone tissue responses were evaluated by resonance frequency analysis (RFA) that were undertaken at 2, 4 and 6 weeks after implant placement in the mandible of mini-pig. Group 1 SP (anodized with sulfuric acid and phosphoric acid implants) demonstrated slightly stronger bone responses than control Group RBM. Group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) demonstrated no difference which were compared with control group. Group 3 GMP (anodized and CMP coated implants) demonstrated slightly stronger and faster bone responses than any other implants. But, all observation result of RF A showed no significant differences between experimental groups with various surface type. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact for group 2 GC. Significantly more bone formation was found inside threaded area for group 2 GC. It was concluded that group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) showed more effects on the bone tissue responses than RBM surface in initial period of implantation. In addition, CMP showed a tendency to promote bone tissue responses.

Effect of Zn Content on the Corrosion Behavior of Ti-6Al-4V Alloy after Plasma Electrolytic Oxidation

  • Hwang, In-Jo;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.159-159
    • /
    • 2017
  • Ti-6Al-4V alloy have been used for dental implant because of its excellent biocompatibility, corrosion resistance, and mechanical properties. However, the integration of such implant in bone was not in good condition to achieve improved osseointergraiton. For solving this problem, calcium phosphate (CaP) has been applied as coating materials on Ti alloy implants for hard tissue applications because its chemical similarity to the inorganic component of human bone, capability of conducting bone formation and strong affinity to the surrounding bone tissue. Various metallic elements are known to play an important role in the bone formation and also affect bone mineral characteristics. Especially, Zn is essential for the growth of the human and Zn coating has a major impact on the improvement of corrosion resistance. Plasma electrolytic oxidation (PEO) is a promising technology to produce porous and firmly adherent inorganic Zn containing TiO2(Zn-TiO2)coatings on Ti surface, and the a mount of Zn introduced in to the coatings can be optimized by altering the electrolyte composition. In this study, effect of Zn content on the corrosion behavior of Ti-6Al-4V alloy after plasma electrolytic oxidation were studied by SEM, EDS, XRD, AC impedance, and potentiodynamic polarization test. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67 mV/s and potential range from -1500 mV to +2000 mV. Also, AC impedance was performed at frequencies ranging from 10 MHz to 100 kHz for corrosion resistance.

  • PDF

Improved Corrosion and Abrasion Resistance of Organic-Inorganic Composite Coated Electro-galvanized Steels for Digital TV Panels

  • Jo, Du-Hwan;Noh, Sang-Geol;Park, Jong-Tae;Kang, Choon-Ho
    • Corrosion Science and Technology
    • /
    • 제14권5호
    • /
    • pp.213-217
    • /
    • 2015
  • Recently, household electronic industries require environmentally-friendly and highly functional steels in order to enhance the quality of human life. Customers especially require both excellent corrosion and abrasion resistant anti-fingerprint steels for digital TV panels. Thus POSCO has developed new functional electro-galvanized steels, which have double coated layers with organic-inorganic composites on the zinc surface of the steel for usage as the bottom chassis panel of TVs. The inorganic solution for the bottom layer consists of inorganic phosphate, magnesium, and zirconium compounds with a small amount of epoxy binder, and affords both improved adhesion properties by chemical conversion reactions and corrosion resistance due to a self-healing effect. The composite solution for the top layer was prepared by fine dispersion of organic-inorganic ingredients that consist of a urethane modified polyacrylate polymer, hardener, silica sol and a titanium complex inhibitor in aqueous media. Both composite solutions were coated on the steel surface by using a roll coater and then cured through an induction furnace in the electro-galvanizing line. New anti-fingerprint steel was evaluated for quality performance through such procedures as the salt spray test for corrosion resistance, tribological test for abrasion resistance, and conductivity test for surface electric conductance regarding to both types of polymer resin and coating weight of composite solution. New composite coated anti-fingerprint steels afford both better corrosion resistance and abrasion properties compared to conventional anti-fingerprint steel that mainly consists of acrylate polymers. Detailed discussions of both composite solutions and experimental results suggest that urethane modifications of acrylate polymers of composite solutions play a key role in enhanced quality performances.

Corrosion Behavior of Ti-6Al-4V Alloy after Plasma Electrolytic Oxidation in Solutions Containing Ca, P and Zn

  • Hwang, In-Jo;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.120-120
    • /
    • 2016
  • Ti-6Al-4V alloy have been used for dental implant because of its excellent biocompatibility, corrosion resistance, and mechanical properties. However, the integration of such implant in bone was not in good condition to achieve improved osseointergraiton. For solving this problem, calcium phosphate (CaP) has been applied as coating materials on Ti alloy implants for hard tissue applications because its chemical similarity to the inorganic component of human bone, capability of conducting bone formation and strong affinity to the surrounding bone tissue. Various metallic elements, such as strontium (Sr), magnesium (Mg), zinc (Zn), sodium (Na), silicon (Si), silver (Ag), and yttrium (Y) are known to play an important role in the bone formation and also affect bone mineral characteristics, such as crystallinity, degradation behavior, and mechanical properties. Especially, Zn is essential for the growth of the human and Zn coating has a major impact on the improvement of corrosion resistance. Plasma electrolytic oxidation (PEO) is a promising technology to produce porous and firmly adherent inorganic Zn containing $TiO_2(Zn-TiO_2)$coatings on Ti surface, and the a mount of Zn introduced in to the coatings can be optimized by altering the electrolyte composition. In this study, corrosion behavior of Ti-6Al-4V alloy after plasma electrolytic oxidation in solutions containing Ca, P and Zn were studied by scanning electron microscopy (SEM), AC impedance, and potentiodynamic polarization test. A series of $Zn-TiO_2$ coatings are produced on Ti dental implant using PEO, with the substitution degree, respectively, at 0, 5, 10 and 20%. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to +2000mV. Also, AC impedance was performed at frequencies ranging from 10MHz to 100kHz for corrosion resistance.

  • PDF

운모상에 인산아연이 도포된 방청안료의 제조 및 성능평가 (Preparation and Performance Evaluation of Zinc Phosphate-Coated Mica Anticorrrosive Pigment)

  • 이유진;박성수;홍성수;이승호;김대성;이근대
    • 청정기술
    • /
    • 제19권3호
    • /
    • pp.257-263
    • /
    • 2013
  • 인산아연이 도포된 운모 안료(ZP/mica)를 인산, 질산아연 그리고 운모를 출발물질로 하여 제조한 후, 방청안료로 사용하였다. 주사전자현미경 및 X-선 회절분석기 등을 이용하여 제조된 안료의 형상과 결정구조를 관찰하였다. 제조된 안료와 에폭시수지를 배합하여 도막을 형성시킨 다음 전기화학적 임피던스법을 이용하여 안료의 방청성을 평가하였다. $70^{\circ}C$에서 합성된 ZP/mica 안료의 방청성이 $20^{\circ}C$에서 제조된 안료보다는 우수하다는 것을 알 수 있었다. $70^{\circ}C$에서 합성된 ZP/mica 안료표면에는 $Zn_3(PO_4)_2{\cdot}2H_2O$ 이외에도 ZnO가 동시에 생성되어 있음을 볼 수 있었다. 합성된 ZP/mica 안료의 우수한 방청성은 운모표면의 아연화합물에 의한 전기화학적 방청기구와 판상구조의 운모에 의한 장벽 방청기구의 상승작용에 기인한 것으로 생각된다.

타이타늄 상에 코팅된 클로르헥시딘 항균제를 함유한 수산화인회석의 특성 (Characteristics of Antibacterial Chlorhexidine-Containing Hydroxyapatite Coated on Titanium)

  • 김민희;황문진;이운영;박영준;송호준
    • 대한치과재료학회지
    • /
    • 제44권3호
    • /
    • pp.263-272
    • /
    • 2017
  • 본 연구에서는 타이타늄 상에 항균제 클로르헥시딘(chlorhexidine; CHX)이 함유된 수산화인회석을 코팅하고 그 특성을 규명하였다. CHX를 혼합한 개조된 생체유사용액(modified simulated body fluid; mSBF)에 타이타늄 디스크를 침적하여 Ti-mSBF-CHX 시편군을 준비하였다. CHX를 함유하지 않은 mSBF에 침적하여 코팅한 Ti-mSBF 시편군을 다시 CHX 용액에 침적하여 Ti-mSBF-adCHX 시편군을 준비하였다. Ti-mSBF 시편 표면에 나노 형태의 결정들로 구성된 구형의 클러스터들이 균일하게 코팅되었다. Ti-mSBF-CHX 시편에서는 이러한 클러스터들과 함께 리본형상의 결정들이 관찰되었으며, 이 결정들에서 높은 CHX 조성이 측정되었다. 두 시편 모두 HAp 결정구조가 지배적이었으며, ${\beta}-TCP$ (tricalcium phosphate)와 OCP (octacalcium phosphate) 결정구조가 Ti-mSBF-CHX 시편에서 관찰되었다. FT-IR 스펙트럼은 Ti-mSBF-adCHX와 Ti-mSBF-CHX 시편군에서 CHX의 피크가 강하게 관찰되었다. 그러나 인산완충식염수(phosphate buffered saline;PBS)에 침적한 후, CHX가 Ti-mSBF-CHX 시편에서는 천천히 용출된 반면, Ti-mSBF-adCHX 시편에서는 빠르게 용출되었다. 따라서 Ti-mSBF-CHX 시편은 골과 유사한 HAp 구조를 가지며 함유된 CHX가 지속적으로 방출될수 있기 때문에 향후 임플란트 시술에서 염증을 방지할 수 있는 코팅법으로 기대된다.

레진과 치과용 도재의 접착 (BONDING BETWEEN RESIN AND CERAMICS)

  • 김선재;이근우;한종현
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.159-168
    • /
    • 2007
  • Statement of problem: Literature showed different results on the durability of bonded ceramic restoration. Purpose: The purpose of this article is to review the effect of surface treatment of ceramics in resin-ceramic bond to get predictable results. Material and method: PubMed data base was utilized to search the articles which were written in English and published in 1986 and 2006. Some electronic published articles which are forthcoming to publish in paper were also included for this review. This review article focused on the effect of acid etching and silane application on the silica based ceramics. The durability of resin-ceramic bonding, the methodology for bond strength test and resin bonding to alumina or zirconia based ceramics were compared in brief at the end of the review. Results and Conclusion: the effect of silane application can be influenced by the contaminations of saliva or solutions. Micromechanical retention by acid etching as well as silane application plays an important role in initial and durable bond strength between resin and ceramic. The use of phosphate modified resin cement following tribochemical silica coating and silane application produced best bond strength for alumina or zirconia based ceramics.

Electrochemical Characteristics of Carbon-coated LiFePO4 as a Cathode Material for Lithium Ion Secondary Batteries

  • Shin, Ho-Chul;Lee, Byung-Jo;Cho, Won-Il;Cho, Byung-Won;Jang, Ho
    • 전기화학회지
    • /
    • 제8권4호
    • /
    • pp.168-171
    • /
    • 2005
  • The electrochemical properties of $LiFePO_4$ as a cathode for Li-ion batteries were improved by incorporating conductive carbon into the $LiFePO_4$. X-ray diffraction analysis and SEM observations revealed that the carbon-coated $LiFePO_4$ consisted of fine single crystalline particles, which were smaller than the bare $LiFePO_4$. The electrochemical performance of the carbon-coated $LiFePO_4$ was tested under various conditions. The carbon-coated $LiFePO_4$ showed much better performance in terms of the discharge capacity and cycling stability than the bare $LiFePO_4$. The improved electrochemical performances were found to be attributed to the reduced particle size and enhanced electrical conductivity of the $LiFePO_4$ by the carbon.

Ti-6Al-7Nb and Ti-6Al-4V 합금의 생체활성에 미치는 콜라겐 처리의 영향 (Effect of Collagen Treatment on Bioactivity of Ti-6Al- 7Nb and Ti-6Al-4V Alloys)

  • 김태호;이갑호;홍순익
    • 한국세라믹학회지
    • /
    • 제45권10호
    • /
    • pp.638-643
    • /
    • 2008
  • Biomimetic apatite formation and deposition behaviors of Ti-6Al-7Nb and Ti-6Al-4V plates in simulated body fluids(SBF) under various conditions were examined. In case of regular samples without collagen treatments the weight gain due to apatite precipitation on the surface in Ti-6Al-4V was found to be higher than in Ti-6Al-7Nb. In case of collagen-coated samples, the weight gain in Ti-6Al-4V continued to be higher than in Ti-6Al-7Nb, but the difference between the two became smaller. Both Ti-6Al-7Nb and Ti-6Al-4V samples with collagen coating exhibited an appreciable increase of weight gain, which may be caused by the interaction between collagen and $Ca^{+2}$ ions. The weight gain was found to be not much affected by the addition of collagen to SBF. The ill-defined granular structure in the presence of collagen can be associated with the increasing volume fraction of amorphous calcium phosphate.

The Regulation of Sugar Metabolism in Huangguan Pears (Pyrus pyrifolia Nakai) with Edible Coatings of Calcium or Pullulan during Cold Storage

  • Kou, Xiaohong;Jiang, Bianling;Zhang, Ying;Wang, Jun;Xue, Zhaohui
    • 원예과학기술지
    • /
    • 제34권6호
    • /
    • pp.898-911
    • /
    • 2016
  • Sugars play many important roles in plant metabolism and directly influence fruit quality. The effects of two edible coatings, 2% calcium chloride and 1% pullulan, on sugar metabolism in postharvest Huangguan pear fruit were investigated during cold storage. The respiration rate, sugar content and composition, sucrose metabolism enzyme activities [acid invertase (AIV), neutral invertase (NI), sucrose synthase (SS), and sucrose phosphate synthase (SPS)] and expression of the AIV gene were analyzed during storage at $0^{\circ}C$ for 210 days. Coating treatments slowed the decrease of sucrose and hexose, the respiration rate, and the activities of AIV, NI, SS and SPS, thus maintaining high total soluble solids (TSS) and titratable acid (TA) contents in the fruit. There were no significant differences in AIV expression or activity between the treated and control groups of fruits. Both of the coatings could inhibit the activities of sucrose-cleaving enzymes, thus slowing the decrease of sugar content and maintaining high fruit quality during cold storage.