• Title/Summary/Keyword: Phasor Method

Search Result 75, Processing Time 0.037 seconds

Electromagnetic Environment of Transmission Line Based on Full Parameter Online Estimation

  • Sun, Zidan;Zhou, Xiaofeng;Liang, Likai;Mo, Yang
    • Journal of Information Processing Systems
    • /
    • v.16 no.2
    • /
    • pp.394-405
    • /
    • 2020
  • The parameters of transmission lines have an influence on the electromagnetic environment surrounding the line. This paper proposes a method based on phasor measurement unit (PMU) and supervisory control and data acquisition (SCADA) to achieve online estimation of transmission line full parameters, such as resistance, reactance and susceptance. The proposed full parameter estimation method is compared with the traditional method of estimating resistance independently based on SCADA system. Then, the electromagnetic environment is analyzed based on the different parameter estimation methods. The example results illustrate that online estimation of transmission line full parameters is more accurate in the analysis of electromagnetic environment, which further confirms its necessity and significance in engineering application.

RHEOLOGIC STUDY ON THE VISCOELASTIC PROPERTIES OF FLOWABLE AND CONDENSABLE RESIN COMPOSITES (유동성 및 응축성 복합레진의 점탄성에 관한 유변학적 연구)

  • Lee, In-Bog;Cho, Byeong-Hoon;Son, Ho-Hyun;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.359-370
    • /
    • 2000
  • The purpose of this investigation was to observe the viscoelastic properties of five commercial flowable(Aeliteflo, Flow it, Revolution, Tetric flow, Compoglass flow), three conventional hybrid(Z-100, Z-250, P-60) and two condensable(Synergy compact, SureFil) resin composites. A dynamic oscillatory shear test was done to evaluate the storage shear modulus (G'), loss shear modulus(G"), loss tangent(tan ${\delta}$) and complex viscosity(${\eta}^*$) of the resin composites as a function of frequency - dynamic frequency sweep test from 0.01 to 100 rad/s at $25^{\circ}C$ - by using Advanced Rheometric Expansion System(ARES). To investigate the effect on the viscosity of resin composites of filler volume fraction, the filler weight % and volume % were measured by means of Archimedes' principle using a pyknometer. The results were as follows 1. The complex viscosity ${\eta}^*$ of flowable resins was lower than that of hybrid resins and significant differences were observed between brands. The complex viscosity ${\eta}^*$ of condensable resins was higher than that of hybrid resins. The order of complex viscosity ${\eta}^*$ at ${\omega}$=10 rad/s was as follows, Surefil, Synergy compact, P-60, Z-250, Z-100, Aeliteflo, Tetric flow, Compoglass flow, Flow it, Revolution. The relative complex viscosity of flowable resins compared to Z-100 was 0.04~0.56 but Surefil was 30.4 times higher than that of Z-100. 2. The storage shear modulus G' and the loss shear modulus G" of flowable resins were lower than those of hybrid resins but those of condensable resins were higher. The patterns of the change of loss tangent, tan ${\delta}$, of resin composites with increasing frequency were significantly different between brands. The phase angles, ${\delta}$, ranged from $30.2{\sim}78.1^{\circ}$ at ${\omega}$=10 rad/s. 3. All composite resins represent pseudoplastic nature with increasing shear rate. 4. The complex shear modulus $G^*$ and the phase angle ${\delta}$ was represented by the frequency domain phasor form, $G^*({\omega})=G^*e^{i{\delta}}=G^*{\angle}{\delta}$. The locus of frequency domain phasor plots in a complex plane was a valuable method that represent the viscoelastic properties of composite resins. 5. There was no direct linear correlationship but a weak positive relation was observed between filler volume % or weight % and the viscosity of the resin composites.

  • PDF

RHEOLOGICAL CHARACTERIZATION OF COMPOSITES USING A VERTICAL OSCILLATION RHEOMETER (수직 진동형 Rheometer를 이용한 복합레진의 유변학적 성질의 측정)

  • Lee, In-Bog;Cho, Byung-Hoon;Son, Ho-Hyun;Lee, Sang-Tag;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.489-497
    • /
    • 2004
  • Objective: The purpose of this study was to investigate the viscoelastic properties related to handling characteristics of composite resins, Methods: A custom designed vertical oscillation rheometer (VOR) was used for rheological measurements of composites. The VOR consists of three parts: (1) a measuring unit, (2) a deformation induction unit and (3) a force detecting unit, Two medium viscous composites, Z100 and Z250 and two packable composites, P60 and SureFil were tested. The viscoelastic material function, including complex modulus $E^{*}$ and phase angle ${\delta}$, were measured. A dynamic oscillatory test was used to evaluate the storage modulus (E'), loss modulus (E") and loss tangent ($tan{\delta}$) of the composites as a function of frequency ($\omega$) from 0.1 to 20 Hz at $23^{\circ}C$. Results: The E' and E" increased with increasing frequency and showed differences in magnitude between brands. The $E^{*}s$ of composites at ${\omega}{\;}={\;}2{\;}Hz$, normalized to that of Z100, were 2.16 (Z250), 4,80 (P60) and 25.21 (SureFil). The magnitudes and patterns of the change of $tan{\delta}$ of composites with increasing frequency were significantly different between brands. The relationships between the complex modulus $E^{*}$, the phase angle ${\delta}$ and the frequency \omega were represented by frequency domain phasor form, $E^{*}{\;}(\omega){\;}={\;}E^{*}e^{i{\delta}}{\;}={\;}E^{*}{\angle}{\delta}$. Conclusions: The viscoelasticity of composites that influences handling characteristics is significant different between brands, The VOR is a relatively simple device for dynamic, mechanical analysis of high viscous dental composites. The locus of frequency domain phasor plots in a complex plane is a valuable method of representing the viscoelastic properties of composites.

Protection Strategies Against False Data Injection Attacks with Uncertain Information on Electric Power Grids

  • Bae, Junhyung;Lee, Seonghun;Kim, Young-Woo;Kim, Jong-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • False data injection attacks have recently been introduced as one of important issues related to cyber-attacks on electric power grids. These attacks aim to compromise the readings of multiple power meters in order to mislead the operation and control centers. Recent studies have shown that if a malicious attacker has complete knowledge of the power grid topology and branch admittances, s/he can adjust the false data injection attack such that the attack remains undetected and successfully passes the bad data detection tests that are used in power system state estimation. In this paper, we investigate that a practical false data injection attack is essentially a cyber-attack with uncertain information due to the attackers lack of knowledge with respect to the power grid parameters because the attacker has limited physical access to electric facilities and limited resources to compromise meters. We mathematically formulated a method of identifying the most vulnerable locations to false data injection attack. Furthermore, we suggest minimum topology changes or phasor measurement units (PMUs) installation in the given power grids for mitigating such attacks and indicate a new security metrics that can compare different power grid topologies. The proposed metrics for performance is verified in standard IEEE 30-bus system. We show that the robustness of grids can be improved dramatically with minimum topology changes and low cost.

A Study on Development of Small Scale Electric Power Management System for Smart Grid (스마트 그리드를 위한 소규모 전력에너지 관리 시스템 개발에 관한 연구)

  • Lee, Chang-Soo;Oh, Hea-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2826-2832
    • /
    • 2012
  • A smart grid is an electric-power grid that employs a new information technology.This technology makes it possible to exchange real-time energy information between suppliers and consumers, finally resulting in high energy efficiency. The energy management system in smart grid provides up to date information on electricity consumption as well as dynamic electricity price to consumers of smart grid system. However, the existing energy management systems only focus on pricing system, for example, real-time electricity prices. In this paper, we try to improve the existing energy management system and propose the energy management system that mainly focuses on the efficiency of electricity consumption. In the proposed management system, PMU(Phasor Measurement Units) installed in switchboards gathers electricity data in a real time. We also propose to use data mining method, which is applied to analyzed electricity data for improving energy efficiency. Also, the proposed energy management system is designed to efficiently control the electricity between PMU and management system in case of a shortage of electricity or surplus electricity.

Position Control of Permanent Magnet Synchronous Motor Using Model Following (영구자석 동기전동기의 모델 추종 위치제어)

  • Yoon, Byung-Do;Kim, Yoon-Ho;Kim, Ki-Yong;Lee, I.Y.;Yoon, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.160-163
    • /
    • 1991
  • Permanent Magnet Synchronous Motor(PMSM) has merits in both simple electrical controllability of dc motor and mechanical reliability of ac motor by applying vector control. The vector control method orients the armature current phasor to be perpendicular to the permenant magnet rotor flux in a two-axis coordinate frame, and provides control characteristics that are similar to those of separately excited dc motors. This paper presents a simple model following scheme for position control of PMSM fed by hysteresis current-controlled PWM inverter. The simulation results show the validity of the proposed control method.

  • PDF

Characteristics Analysis of Tubular Linear Induction Motor Specially-designed for Elevator (엘리베이터용 TLIM의 특성해석)

  • Im, Dal-Ho;Kim, Young-Joong;Yoon, Sang-Baeck;Hwang, Sang-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.612-614
    • /
    • 1992
  • This paper presents the analysis method of TLIM, for the purpose of developing linear induction motor drive for elevators. The transfer matrix to multilayer on cylindrical coordinate is derived. The equivalent circuit constructed from coupling complex phasor makes it possible to obtain characteristics of TLIM. The validity of the method lo verified by comparing the experimental and theoretical results for a pilot machine in locked status.

  • PDF

A fault location algorithm using iterative method at unbalance conditions for distribution feeder systems (불평형시 반복추정기법을 이용한 배전계통 고장점 표정 알고리즘)

  • Lee, D.S.;Jin, B.G.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Ahn, B.S.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.121-123
    • /
    • 2001
  • This paper presents a fault location algorithm using iterative method at unbalance condition for distribution feeder systems. Distribution feeders include single phase and three phase laterals. The proposed algorithm achieves a high accuracy by continuously updating voltage and current phasor using the phase components and admittance load model.

  • PDF

Electrodynamic Superconducting Maglev System with Quadruple Armature Windings (선형동기전동기의 전기자권선을 이용한 초전도 반발식 자기부상열차 시스템)

  • Hong, Soon-Heum;Cha, Guee-Soo;Lee, Ki-Sik;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.199-201
    • /
    • 1994
  • In this paper, The characteristics of the new superconducting maglev system which has quadruple armature windings is examined. This system can generate guidance force and levitation force as well as propulsion force by single ground coil. The time-domain analysis method and phasor analysis method are derived to analyze the characteristics of the proposed system. From the numerical examples for two kind of armature winding configurations, it is shown that the levitation force and guidance force can be generated by single armature winding of the linear synchronous motor without any other ground coils for levitation and guidance, and that double layer configuration has better characteristics in the qualitive characteristics. like as efficiency, pulsation of the electromagnetic forces and drag ratio, than the single layer configuration.

  • PDF

An EMM Approach to Derive an Energy Integral for the Direct Method of Stability Analysis in Power Systems

  • Moon, Young-Hyun
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.1
    • /
    • pp.58-69
    • /
    • 1996
  • This paper presents a new approach to derive an energy integral based on an Equivalent Mechanical Model(EMM), which is developed by introducing imaginary springs for line resistances. The proposed EMM shows that phasor currents and voltages are directly analogous to the two-dimensional force and displacement vectors, respectively. Through rigorous energy analysis of the proposed EMM, an exact energy integral expression is derived for multimachine systems, and several useful theorems are developed to derive an energy integral for power systems with detailed generator models the energy integral exactly reflects the internal resistance, saliency and flux-decaying effects of the generator. Finally, an illustrative example is given for a multimachine system adopting the Eq'-model for generators, which shows that the consideration of a detailed generator model does not aggravate the complicacy of the direct method of stability analysis in multimachine systems.

  • PDF