• Title/Summary/Keyword: Phasor Measurement Unit

Search Result 38, Processing Time 0.032 seconds

A Study on the Application of Under Voltage Load Shedding Scheme in Line Contingency considering Motor Load (모터부하를 고려한 상정사고 발생 시 저전압 부하차단 적용 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • Failure of high-voltage transmission line, which is responsible for large-scale power transmission, can be reason for system voltage instability. There are many methods to prevent voltage instability like adjustment of equipment, the generator voltage setting, and load shedding. Among them, the load shedding, have a problem of economic loss and cascading effect to power system. Therefore, the execution of load shedding, amount and timing is very important. Conventionally, the load shedding setting is decided by the preformed simulation. Now, it is possible to monitor the power system in real time by the appearance of PMU(Phasor Measurement Unit). By this reason, some of research is performed about decentralized load shedding. The characteristics of the load can impact to amount and timing of decentralized load shedding. Especially, it is necessary to consider the influence of the induction motor loads. This paper review recent topic about under voltage load shedding and compare with decentralized load shedding scheme with conventional load shedding scheme. And simulations show the effectiveness of proposed method in resolving the delayed voltage recovery in the Korean Power System.

A Study on the Low Frequency Oscillation Using PMU Measurement Data (PMU 데이터를 이용한 저주파 진동분석 연구)

  • Kim, Yonghak;Nam, Suchul;Ko, Baekkyeong;Kang, Sungbum;Shim, Kwansik
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • It is very important to evaluate on/off-line stability to operate the power system stably and economically. Until now, we have continuously secured the operation reliability of the power system through the evaluation of transient, voltage and small signal stability. This paper proposes that it is possible to operate in KWAMS by applying the multi-section analysis and subspace methods and verifying the reliability of the algorithms to directly estimate the dominant oscillation mode of the power system from the signal waveform acquired from the phasor measurement units. In addition, this paper shows that the dominant oscillation mode can be detected from real-time measurement data in power systems. Therefore, if we can monitor the state of the power system in real time, it is possible to avoid a large-scale power outage by knowing the possibility of the power system accident in advance.

An ASIC implementation of Phasor Measurement Unit based on Sliding-DFT (순환 DFT에 기초한 페이저 연산 장치의 ASIC 구현)

  • 김종윤;김석훈;장태규;김재화
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.143-146
    • /
    • 2001
  • 본 논문에서는 다 채널 페이저 연산 장치를 전용하드웨어로 구현하기 위한 설계 구조에 대하여 제시하였으며, 이를 연산량이 많은 곱셈기를 시분할에 의해 공유하는 구조를 제시하였다. 또한 페이저 측정을 위한 Sliding-DFT 알고리즘을 순환 구현할 경우의 근사구현 오차에 관한 정량적인 연구를 수행하였다. 이러한 오차 영향의 해석을 기반으로 하여 곱셈기 공유 구조를 적용한 페이저 연산 장치를 설계하고, 설계한 하드웨어의 내부동작을 보여주는 시뮬레이션을 통해 설계의 정확성을 확인하였다

  • PDF

Wavelet-Based Dynamic Phasor Estimation and Performance Evaluation (웨이브렛 분석 기반 다이나믹 페이저 추정 및 성능 비교평가)

  • Kim, Do-In;Chun, Tae Yoon;Yoon, Sung-Hwa;Lee, Gyul;Park, Jin Bae;Shin, Yong-June
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.171-172
    • /
    • 2015
  • PMU (Phasor Measurement Unit)는 전력시스템의 노드에서 실시간으로 시간 동기화된 페이저 정보를 측정하여 전력계통 모니터링을 가능하게 하는 장치이다. 이 때, PMU가 모니터링 장치로서 활용되기 위해서는 고신뢰도의 페이저 정보 측정이 요구된다. 기본적인 페이저 추정기법은 푸리에 변환을 이용하여 정현파 신호의 기본주파수 성분을 분석하는 것으로 본 논문에서는 푸리에 변환 기반 페이저 추정기법과 웨이브렛 기반 페이저 추정기법의 성능을 분석하여 웨이브렛 기반 페이저 추정기법의 타당성을 검토하고자 하였다. 페이저 추정기법의 평가에는 IEEE 표준에 따른 TVE (Total Vector Error) 개념을 사용하며 정현파 신호의 진폭변화와 위상변화 및 잡음발생 환경의 진폭변화에 대하여 페이저 추정 기법들의 성능평가로 신뢰성을 확인하였다.

  • PDF

A Study on Frequency Measurement Technique for Wide Area Protection (광역보호를 위한 주파수 측정기법에 관한 연구)

  • Park, Chul-Won;Kim, Yoon-Sang;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2023-2024
    • /
    • 2008
  • 근래 초기고장(seed fault)에 대한 적절치 못한 대책들이 광역정전으로 파급되어 그 피해정도가 매우 심각하다. 전력의 안정적 공급에 대한 중요성이 새롭게 부각되고 그 예방책에 대한 다각적인 연구가 요구되고 있다. 이에 위성망을 이용한 위기 관리시스템에 대한 필요성이 제기되었다. 본 논문에서는 광역보호를 위해 sPMU(satellite Phasor Measurement Unit), 전력계통 상태감시장치(Power System Dynamic Monitor:PSDM)에 중요한 요소로서 전력계통에서 가장 중요한 지표중의 하나인 주파수에 대한 여러 가지 측정방법을 다룬다. 향후 정상상태와 과도상태에서도 측정시간 단축과 측정오차를 줄일 수 있는 최적의 주파수 계측기법을 개발하기 위함이다.

  • PDF

Protection Strategies Against False Data Injection Attacks with Uncertain Information on Electric Power Grids

  • Bae, Junhyung;Lee, Seonghun;Kim, Young-Woo;Kim, Jong-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • False data injection attacks have recently been introduced as one of important issues related to cyber-attacks on electric power grids. These attacks aim to compromise the readings of multiple power meters in order to mislead the operation and control centers. Recent studies have shown that if a malicious attacker has complete knowledge of the power grid topology and branch admittances, s/he can adjust the false data injection attack such that the attack remains undetected and successfully passes the bad data detection tests that are used in power system state estimation. In this paper, we investigate that a practical false data injection attack is essentially a cyber-attack with uncertain information due to the attackers lack of knowledge with respect to the power grid parameters because the attacker has limited physical access to electric facilities and limited resources to compromise meters. We mathematically formulated a method of identifying the most vulnerable locations to false data injection attack. Furthermore, we suggest minimum topology changes or phasor measurement units (PMUs) installation in the given power grids for mitigating such attacks and indicate a new security metrics that can compare different power grid topologies. The proposed metrics for performance is verified in standard IEEE 30-bus system. We show that the robustness of grids can be improved dramatically with minimum topology changes and low cost.

Jeju area's Voltage Stability Analysis which use the Real Time Voltage Stability Analysis Program (실시간 전압안정도 프로그램을 이용한 제주지역 전압안정도)

  • Lee, Sung-Woo;Ahn, Kyo-Sang;Seo, Dong-Wan;Jang, Moon-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1387-1392
    • /
    • 2012
  • These days people use a lot of electric power, because industry advancement and a standard of living is elevated. So voltage stability analysis and control problems are very important in these days. U.S.A has already developed voltage stability analysis program, and use it on power transmission scheme such as generator overhaul, transmission line off and so on. So voltage stability analysis is more and more interested in Korea, too. In this paper, we introduce a standard theory of voltage stability analysis and real time voltage stability analysis program that use sPMU(Satellite Phasor Measurement Unit). And we also introduce the calculation result about voltage stability in Jeju power transmission system.

A Study on the Voltage Stability Control Scheme using Real-time Monitoring Data (실시간 감시 정보를 이용한 전압안정도 제어 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.206-212
    • /
    • 2017
  • In this paper, using the power system information obtained from real-time monitoring device, to analyze the voltage stability margin index and described the voltage stability control scheme for voltage stability enhancement. Based on the utilization of the voltage stability monitoring index based on local information provided by the PMU(Phasor Measurement Unit), the purpose of the plan is to control the system stably in real time. In order to apply the load control scheme, the voltage stability margin is calculated using the data acquired through the PMU installed in each load bus. If the voltage drops below a certain level, load control is performed for each. The effectiveness of the voltage stability control measures is applied to the actual KEPCO system to analyze the effectiveness.

A Study on Smart Grid Data Management and Utilization (스마트그리드 데이터 관리 및 활용 기술 연구)

  • Oh, Do-Eun;Kim, Young-Jun;Kim, Young-Il;Choi, Seung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1987-1988
    • /
    • 2011
  • 국내외적으로 스마트그리드 구축을 위해 스마트미터, 센서, PMU(Phasor Measurement Unit) 및 IED(Intelligent Electronic Device) 등의 다양한 장치들이 전력시스템에 보급되고 있다. 스마트미터는 전력소비자의 전력사용량 뿐 아니라 다양한 계량 정보를 상위 수집시스템에 전달할 수 있는 기능을 갖추고 있으며, 계통에 설치된 여러 종류의 센서, PMU 및 IED들 또한 상위 감시제어시스템에 수많은 데이터를 제공한다. 이렇듯 스마트그리드 구축에 따른 스마트미터의 보급, 센서 및 IED의 확산에 따라 전력시스템에서 발생되는 방대한 데이터의 관리 문제와 어떻게 이들 데이터를 전력시스템 운영에 유용하게 활용할 수 있는가에 대한 문제들이 새롭게 부각되고 있다. 본 논문은 스마트그리드 구축에 따라 발생되는 수많은 데이터의 관리와 이들 데이터의 활용사례에 대하여 기술한다.

  • PDF

A Study on System Protection Scheme Using a Voltage Instability Index (전압 안정도 지수를 고려한 계통 보호방안 연구)

  • Jeon, Woong-Jae;Kim, Tae-Kyun;Kang, Sang-Kyun;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.181-182
    • /
    • 2006
  • GPS(Global Positioning System)을 기반으로 한 PMU(Phasor measurement Unit) 장치는 계통의 여러 가지 동특성 정보를 내포하고 있는 페이저 정보를 제공한다. 이러한 PMU 정보를 이용하여 계통의 전압 안정도를 판단, 감시하여 보다 신뢰성이 높게 계통을 안정적으로 운영을 할 수 있고, 계통보호를 위한 Shunt Capacitor 투입 시 적절한 시기와 양을 결정할 수 있도록 도와준다. 본 논문에서는 기존의 저전압 계전기를 이용한 저전압 현상과 실시간 지역정보를 이용한 전압 안정도 지수를 함께 고려함으로써 보다 신속하고 신뢰성 높은 계통 보호방안을 모색하고, 이를 실시간 디지털 시뮬레이터인 HYPERSIM을 활용하여 순시치 환경에서 모의하였다.

  • PDF