• Title/Summary/Keyword: Phase-to-ground

Search Result 958, Processing Time 0.028 seconds

The basic experiments for the fabrication of the SPUDT type Inter using the SFIT type filter (SFIT형태를 이용한 SPUDT형 필터제작에 관한 기초실험)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1916-1923
    • /
    • 2007
  • We have studied to obtain the SAW filter for the passband was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and thin we performed computer-simulated by simulator. We cm fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulation. Also, we have performed to obtain the properly design conditions about phase shift of the SAW filter for WCDMA. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are $5000\;{\AA}$ and $3.6{\mu}m$ respectively. And we have employed that the distances from the hot electrode to the reflector are $2.0{\mu}m$, $2.4{\mu}m$ and the distance from the hot electrode to the ground is $1.5{\mu}m$ respectively. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 7,8MHz. And we could obtain that return loss is less then -18dB, ripple characteristics is probably 3dB and triple transit echo is less then -25dB after when we have matched impedance.

Application of HWAW Method to Detect Underground Anomaly in Shallow Depth (지표 근처 지중 이상체 파악을 위한 HWAW 기법의 적용)

  • Bang, Eun-Seok;Kim, Gyeong-Seob;Son, Jeong-Sul;Kim, Dong-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1C
    • /
    • pp.11-20
    • /
    • 2009
  • A new alternative method based on HWAW method to detect underground anomaly was introduced. The location of underground anomaly can be estimated by using 2-dimensional image of phase velocity image with position and wavelength based on distortion phenomena of surface wave due to underground anomaly. Overall procedure of proposed method such as field testing, signal processing and interpretation of the result was introduced. Numerical verification study was performed by using various ground models containing underground anomaly. According to the condition of anomaly, the propagation and reflection characteristics of surface wave were different and this could be more easily shown in the image of phase velocity. Some rules of distortion phenomena were found and these become clues for estimating underground anomaly in interpreting real field data. Field verification tests were performed with conventional geophysical methods such as DC resistivity method and GPR. Though field condition is not homogeneous like numerical models, similar distortion phenomena were found in the testing results and estimated location of underground anomaly was agreed well with the results of another geophysical methods.

TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH (치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향)

  • Kim, Seong-Oh;Choi, Byung-Jai;Lee, Jae-Ho;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

Processing of Downhole S-wave Seismic Survey Data by Considering Direction of Polarization

  • Kim, Jin-Hoo;Park, Choon-B.
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.4
    • /
    • pp.321-328
    • /
    • 2002
  • Difficulties encountered in downhole S-wave (shear wave) surveys include the precise determination of shear wave travel times and determination of geophone orientation relative to the direction of polarization caused by the seismic source. In this study an S-wave enhancing and a principal component analysis method were adopted as a tool for determination of S-wave arrivals and the direction of polarization from downhole S-wave survey data. An S-wave enhancing method can almost double the amplitudes of S-waves, and the angle between direction of polarization and a geophone axis can be obtained by a principal component analysis. Once the angle is obtained data recorded by two horizontal geophones are transformed to principal axes, yielding so called scores. The scores gathered along depth are all in-phase, consequently, the accuracy of S-wave arrival picking could be remarkably improved. Applying this processing method to the field data reveals that the test site consists of a layered ground earth structure.

  • PDF

Gait Phases Detection and Judgment based Multi Biomedical Signals (다중 생체 신호 기반 보행 단계 감지 및 판단)

  • Kim, S.J.;Jeong, E.C.;Song, Y.R.;Yoon, K.S.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.43-48
    • /
    • 2012
  • In this paper, we present the method of gait phases detection using multi biomedical signals during normal gait. Electromyogram(EMG) signals, muscle of thigh angle measurement device and resistive sensors are used for experiments. We implemented a test targeting five adult male and identified the pattern of EMG signal of normal gait. For acquiring the EMG signal, subjects attached surface Ag/AgCl electrodes to quadriceps femoris, biceps femoris, tibialis anterior and gastrocnemius medialis. Resistance sensors are attached to the heel toe and soles of the each feet for measuring attachment state of between feet and ground. Infrared sensors are attached on the thigh and thigh angle measurement device has the range from flection 25 degrees to extension 20 degrees. The results of this paper, The stance and swing phase could be confirmed during the normal gait and be classified in detail the eight steps.

  • PDF

The analysis of lower extremities injury on depth jump (Depth Jump 시 하지 관절 상해에 관한 운동역학적 분석)

  • So, Jae-Moo;Kim, Yoon-Ji;Lee, Jong-Hee;Seo, Jin-Hee;Chung, Yeon-Ok;Kim, Koang-Ki
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.127-142
    • /
    • 2005
  • The purpose of this study was to analysis biomechanics of the lower extremities injury the heights(40cm, 60cm, 80cm) of jump box as performed depth jump motion by 6 females aerobic athletes and 6 non-experience females students. The event of depth jump were set to be drop, landing and jump. The depth jump motions on the force plate were filmed using a digital video cameras, and data were collected through the cinematography and force plate. On the basis of the results analyzed, the conclusions were drawn as follows: 1. The landing time of skill group was shorter than unskill group at 40cm, 60cm drop height during drop-landing-jump phase especially. The landing time of 60cm drop height was significant between two group(p<.05). 2. The peak GRF of sagittal and frontaI direction following drop height improve was variety pattern and the peak vertical force of 40cm drop height was significantly(p<.05). 3. The magnitude of peak passive force was not increase to change the drop height. 4. The peak passive forces was significant at 40cm drop height between two groups(p<.05)

Correction of Accelerogram in Frequency Domain (주파수영역에서의 가속도 기록 보정)

  • Park, Chang Ho;Lee, Dong Guen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.71-79
    • /
    • 1992
  • In general, the accelerogram of earthquake ground motion or the accelerogram obtained from dynamic tests contain various errors. In these errors of the accelerograms, there are instrumental errors(magnitude and phase distortion) due to the response characteristics of accelerometer and the digitizing error concentrated in low and high frequency components and random errors. Then, these errors may be detrimental to the results of data processing and dynamic analysis. An efficient method which can correct the errors of the accelerogram is proposed in this study. The correction of errors can be accomplished through four steps as followes ; 1) using an interpolation method a data form appropriate to the error correction is prepared, 2) low and high frequency errors of the accelerogram are removed by band-pass filter between prescribed frequency limits, 3) instrumental errors are corrected using dynamic equilibrium equation of the accelerometer, 4) velocity and displacement are obtained by integrating corrected accelerogram. Presently, infinite impulse response(IIR) filter and finite impulse response (FIR) filter are generally used as band-pass filter. In the proposed error correction procedure, the deficiencies of FIR filter and IIR filter are reduced and, using the properties of the differentiation and the integration of Fourier transform, the accuracy of instrument correction and integration is improved.

  • PDF

Characteristics of Flow Rate Control for Solid Fuel Gas Generator (고체연료를 사용하는 가스발생기 유량조절특성 연구)

  • Choi, Ho-Jin;Hyun, Hyung-Soo;Lee, Kyoung-Ho;Park, Ik-Soo;Lee, Jae-Youn;Youn, Hyun-Gull;Lim, Jin-Shik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.293-298
    • /
    • 2011
  • The combustion and flow-rate control characteristics of fuel-rich gas generator which could be adopted to Ducted Rocket propulsion system are investigated. The gas generator is designed considering the design requirements of propulsion system and solid fuel for fuel-rich combustion is developed then adopted to ground test. The results of combustion test show the necessity of the special analysis tool for estimating the gas generator performance where multi-phase flow of fuel-rich gas exists. During the flow-rate control test, characteristics of gas generator pressure with the angle of valve are analyzed and, method to estimate the pressure of gas generator is suggested using the relation between the valve exit area and discharge coefficient.

  • PDF

Design of Clock Synchronization Scheme for Pseudolite (의사위성 시각동기 기법 설계)

  • Lee, Ju Hyun;Hwang, Soyoung;Yu, Dong-Hui;Lee, Sang Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.6
    • /
    • pp.1312-1317
    • /
    • 2013
  • Pseudolite is a contraction of the term "pseudo-satellite", used to refer to something that is not a satellite which performs a function commonly in the domain of satellites. Pseudolite are most often small transceivers that are used to create a local, ground-based GPS alternative. Pseudo-range measurement of pseudolite has around 300m range error, when time synchronization error of $1{\mu}sec$ occurs. Therefore the time synchronization methods play an important part in navigation augmentation using pseudolite. This paper proposes three clock synchronization methods that are installation method of pseudolite station, method using KRISS-UTC and method using PRN code phase difference for pseudolite. The simulation platform structure is presented for evaluating proposed clock synchronization performance.

Specification Establishment and Verification for KSLV-I EMC Control (나로호의 EMC 통제를 위한 규격설정 및 검증)

  • Ji, Ki-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.311-318
    • /
    • 2014
  • Electromagnetic compatibility(EMC) performance of the first Korea space launch vehicle(KSLV-I) should be ensured and verified in order to guarantee the normal operation among the spacecraft, ground facilities which are installed in the space center, and other wireless communication networks. For the purpose of the EMC performance verification, pertinent EMC test specifications, methods, and procedures for both the subsystems and the system should be established in consideration of operational properties and electromagnetic environmental effects. And it is required to maintain and control the EMC properties consistently in accordance with the determined specifications up to the program closing phase. In this paper, sequential management work conducted during the overall development process of the KSLV-I is explained, and not only the phased EMC test plan for each model of the KSLV-I and its subsystem but also test method, specification, and results of the verification tests are presented. And also, multipaction analysis results are presented.