멀티레벨 상변화 메모리 응용을 위해 화학기상증착법으로 저온에서 증착시킨 InSbTe 박막의 특성평가 (Conformal Properties of InSbTe Thin Films Grown at a Low Temperature by MOCVD for Multi Level Phase-Change Memory Applications)

  • 안준구;허성기;김청수;이정용;윤순길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.215-215
    • /
    • 2010
  • The feasibility of InSbTe (IST) chalcogenide materials prepared by metalorganic chemical vapor deposition (MOCVD) for phase-change memory (PRAM) applications was demonstrated. Films grown below $225^{\circ}C$ exhibited an amorphous structure, and the films grown at $300^{\circ}C$ Cincluded various crystalline phases such as In-Sb-Te, In-Sb, In-Te, and Sb-Te. The composition of the amorphous films grown at $225^{\circ}C$ was dependent on the working pressure. Films grown at $225^{\circ}C$ exhibited a smooth morphology with a root mean square(rms) roughness of less than 1nm, and the step-coverage of the films grown on a trench structure with an aspect ratio of 5:1 was greater than 90%. An increase in deposition time increased the filling rate, while retaining the conformal step-coverage. Films grown at $225^{\circ}C$ for 3h in a working pressure of $13{\times}10^2$ Pa exhibited a reproducible and complete filling in a trench structure.

  • PDF

플라스틱과 금속재료를 이용한 3 차원 박벽 제품의 쾌속 제작 (Rapid Manufacturing of 3D Thin-walled Products using Plastics and Metals)

  • 신보성;강보식;박재현;노치현
    • 한국정밀공학회지
    • /
    • 제23권8호
    • /
    • pp.195-202
    • /
    • 2006
  • High-speed machining (HSM) with excellent quality and dimensional accuracy has been widely used to create 3D structures of metal and plastics. However, the high-speed machining process is not suitable for the rapid realization of 3D thin-walled product because it consumes considerably long time in fixturing process of a work piece. In this paper, an effective rapid manufacturing process is proposed to fabricate 3D thin-walled products directly using HSM, phase change filling and ultrasonic welding. The filling process is useful to hold the thin-walled product during the machining step. The ultrasonic welding process is introduced to make one piece product from two piece parts that are machined by HSM and filling process. The proposed rapid manufacturing (RM) process has been shown that the RM process enables to fabricate the 3D thin-walled products using ABS plastics and aluminum metals from 3D CAD data to functional parts.

압축성과 상변화를 고려한 사출성형의 충전과정 해석 (Analysis for Filling Stage of Injection Molding Considering Compressibility and Phase Change)

  • 이상찬;박창언;양동열
    • 한국정밀공학회지
    • /
    • 제18권12호
    • /
    • pp.60-65
    • /
    • 2001
  • To simulate the real molding conditions, the effects of phase change and compressibility of the resin were considered in the present investigation. A modified Cross model with either an Arrhenius-type or WLF-type functional form was used for modeling viscosity of the resin. A double-domain Tait equation of state was employed to describe the compressibility of the resin during molding. The energy balance equation including latent-heat dissipation fur semi-crystalline materials was solved in order to predict the solidified layer and temperature profile. Injection molding experiments were carried out using polypropylene(PP) in the present study. Based on the comparison between experiments and simulations, it was found out the predicted pressure distributions and melt front propagations were accurate. Thus it was concluded that the program developed in this study was proved to be useful in simulations of injection molding process.

  • PDF

Image Findings of Sarcomatous Intrahepatic Cholangiocarcinoma Focused on Gd-EOB-DTPA Enhanced MRI: A Case Report

  • Kim, Ki Beom;Kim, Seong Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권1호
    • /
    • pp.47-51
    • /
    • 2015
  • Sarcomatous Intrahepatic cholangiocarcinoma is a rare but an aggressive variant of cholangiocarcinoma with a very poor prognosis. A 79-year-old man was admitted to our hospital because of incidentally found liver mass. Magnetic resonance imaging (MRI) revealed well-defined hypointense mass on T1WI and heterogeneous hyperintense mass on T2WI. Gd-EOB-DTPA enhanced study shows peripheral rim-like enhancement in arterial phase and progressive concentric filling of contrast in delayed phase. And mass shows significant enhancement in hepatobiliary phase. The pathologic diagnosis was intrahepatic cholangiocarcinoma with sarcomatous change.

암모니아 용기 파열사고 분석을 통한 가용전식 안전밸브 유효성 확인 실증 연구 (A Study on the Validity of TPRD by Analysis of Ammonia Container Rupture Accidents)

  • 신현국;김정환;이재훈
    • 한국가스학회지
    • /
    • 제27권3호
    • /
    • pp.35-40
    • /
    • 2023
  • 과충전, 이상 온도 상승 등 이상 상황이 발생하는 조건에서 암모니아 용기의 파열 사고의 예방을 위해서는 용기에 부착된 가용전식 안전밸브의 작동 메카니즘 분석을 통한 사고 예방대책 마련이 필요하다. 본 연구에서는 가압 조건에서 암모니아 용기에 작용하는 응력 분석, 온도 변화에 따른 밀도 변화 분석, 그리고 용기 충전량과 온도 및 압력 변화에 대한 상관관계를 제시하였다. 또한, 암모니아 용기의 최대 충전량을 계산하고, 상평형 선도를 통해 해당 충전량에서의 온도·압력을 산출했다. 이를 바탕으로 가용전식 안전밸브의 적정 용융점을 도출하고 용융 온도 실험을 통해 이를 검증하였다. 이와 같은 연구 결과를 바탕으로 암모니아 용기 파열 사고의 예방을 위한 조건을 제시하였다.

DMAB에 의한 P형 실리콘 기판 무전해 니켈-붕소 도금 (Electroless Nickel-Boron Plating on p-type Si Wafer by DMAB)

  • 김영기;박종환;이원해
    • 한국표면공학회지
    • /
    • 제24권4호
    • /
    • pp.206-214
    • /
    • 1991
  • In the basic study of selective electroless Ni plating of Si wafers, plating rate and physical properties are investigated to obtain optimum conditions of contact hole filling. Si wafers are excellently activated in the concentration of 0.5M IF, 1mM PdCl2, 2mM EDTA at $70^{\circ}C$, 90sec. The optimum condition of Ni-B deposition on p-type Si wafers is 0.1M NiSO4, 0.11M Citrate, $70^{\circ}C$, pH6.8, 8mM DMAB. The main factor in the sheet resistences variation of films is amorphous and on heat treating matrix was transformed into a stable phase (Ni+Ni3B) at $300-400^{\circ}C$. But pH or DMAB concentration in the plating solution doesn't play role of heat-affected phase change.

  • PDF

Atomic layer deposition of In-Sb-Te Thin Films for PRAM Application

  • Lee, Eui-Bok;Ju, Byeong-Kwon;Kim, Yong-Tae
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.132-132
    • /
    • 2011
  • For the programming volume of PRAM, Ge2Sb2Te5(GST) thin films have been dominantly used and prepared by physical vapor deposition (PVD), chemical vapor deposition (CVD), atomic layer deposition (ALD). Among these methods, ALD is particularly considered as the most promising technique for the integration of PRAM because the ALD offers a superior conformality to PVD and CVD methods and a digital thickness control precisely to the atomic level since the film is deposited one atomic layer at a time. Meanwhile, although the IST has been already known as an optical data storage material, recently, it is known that the IST benefits multistate switching behavior, meaning that the IST-PRAM can be used for mutli-level coding, which is quite different and unique performance compared with the GST-PRAM. Therefore, it is necessary to investigate a possibility of the IST materials for the application of PRAM. So far there are many attempts to deposit the IST with MOCVD and PVD. However, it has not been reported that the IST can be deposited with the ALD method since the ALD reaction mechanism of metal organic precursors and the deposition parameters related with the ALD window are rarely known. Therefore, the main aim of this work is to demonstrate the ALD process for IST films with various precursors and the conformal filling of a nano size programming volume structure with the ALD?IST film for the integration. InSbTe (IST) thin films were deposited by ALD method with different precursors and deposition parameters and demonstrated conformal filling of the nano size programmable volume of cell structure for the integration of phase change random access memory (PRAM). The deposition rate and incubation time are 1.98 A/cycle and 25 cycle, respectively. The complete filling of nano size volume will be useful to fabricate the bottom contact type PRAM.

  • PDF

방사성동위원소 배뇨방광촬영술의 신장예후 예측성능 (Predictive Efficacy of Radioisotope Voiding Cystography for Renal Outcome)

  • 김석기;이동수;김광명;최황;정준기;이명철
    • 대한핵의학회지
    • /
    • 제34권2호
    • /
    • pp.135-143
    • /
    • 2000
  • 목적: 방광요관역류는 감염과 동반될 경우 신장기능이 비가역적으로 손상될 수 있으므로 신기능의 손상이 오기 전에 역류를 제거하여야 한다. 방사성동위원소 배뇨방광촬영술에 의해 발견된 역류의 특징을 이용하여 신장의 예후를 예측할 수 있는지 그리고 어떤 특징이 중요한지 조사하였다. 대상과 방법: 35명의 환아(남 18, 여 17)의 66개의 신장을 대상으로 초기 DMSA 스캔을 시행하고 이어 방사성동위원소 배뇨방광촬영술을 한 후 다시 DMSA 추적 스캔, 초음파 및 임상소견으로 악화여부를 평가하였다. 방사성동위원소 배뇨방광촬영술에 나타난 각 배뇨시기별 역류량과 역류범위를 각각 또는 종합하여 단계별 다변량판별분석을 하였다. 결과: 충만시의 역류범위와 배뇨후기의 역류량과 역류범위가 유의한 판별능을 보였다. 역류량과 범위를 종합한 변수를 이용한 판별분석에서는 총 역류량이 유의한 변수이었다. 충만시의 역류범위과 배뇨후기의 역류량과 역류범위로 구성한 판별식은 재래식 역류등급으로 예후를 예측할 때 보다 양성예측율과 특이도가 높았다. 결론: 방사성동위원소 배뇨방광 촬영술에 나타난 각 배뇨시기별 역류의 양과 범위를 종합하여 신장의 예후를 예측할 수 있다.

  • PDF

주조공정의 수치해석을 위한 3차원 전산모델 개발에 관한 연구 (A Study on the Development of a Three Dimensional Numerical Model for the Casting Processes)

  • 목진호;;이진호
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1436-1444
    • /
    • 2002
  • A three dimensional numerical model was developed to analyze the mold filling and solidification processes straightforwardly in a casting processes. On the basis of the SIMPLER algorithm, the VOF method and the Equivalent Specific Heat method were adopted to deal with the free surface behavior and the latent heat evolution. The complete model has been validated using exact solutions and experimental results. The importance of three-dimensional effects has been highlighted by comparing the results from the three-dimensional analysis with those given by a two-dimensional analysis.

자동변속기 변속품질 향상을 위한 클러치 자동보정 알고리즘 개발 (Development of Clutch Auto Calibration Algorithm for Automatic Transmission Shift Quality Improvement)

  • 정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권3호
    • /
    • pp.47-56
    • /
    • 2020
  • As a shift control of automatic transmission was managed with the electronic control unit (ECU), shift quality which is a measure of shift shock during gear change has markedly improved. However, the initial clutch pressure control of the clutch filling phase should continue to rely on the predetermined control input since the input and output speeds are unchanged until the shifting process attains the inertia phase. It is critical to minimize the clutch response time and control the clutch pressure accurately at the end of clutch fill to achieve quick shift response and smoothness. Advanced transmission companies have adopted an auto calibration method which establishes the databases for the clutch piston fill-up attributes and the frictional characteristics of the disks. In this study, a distinctive auto calibration algorithm for forklift transmission under development is proposed and verified with the real-vehicle test. The experimental calibration results showed consistent turbine dynamics at the initial stage of shifts with the properly calibrated clutch-fill control parameters. By using this technique, it is necessary to finalize the shift control for the various operation conditions.