• 제목/요약/키워드: Phase-Difference Parameters

검색결과 247건 처리시간 0.032초

Development of a novel reconstruction method for two-phase flow CT with improved simulated annealing algorithm

  • Yan, Mingfei;Hu, Huasi;Hu, Guang;Liu, Bin;He, Chao;Yi, Qiang
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1304-1310
    • /
    • 2021
  • Two-phase flow, especially gas-liquid two-phase flow, has a wide application in industrial field. The diagnosis of two-phase flow parameters, which directly determine the flow and heat transfer characteristics, plays an important role in providing the design reference and ensuring the security of online operation of two-phase flow system. Computer tomography (CT) is a good way to diagnose such parameters with imaging method. This paper has proposed a novel image reconstruction method for thermal neutron CT of two-phase flow with improved simulated annealing (ISA) algorithm, which makes full use of the prior information of two-phase flow and the advantage of stochastic searching algorithm. The reconstruction results demonstrate that its reconstruction accuracy is much higher than that of the reconstruction algorithm based on weighted total difference minimization with soft-threshold filtering (WTDM-STF). The proposed method can also be applied to other types of two-phase flow CT modalities (such as X(𝛄)-ray, capacitance, resistance and ultrasound).

다중산란 환경에서의 두개의 산란 위상함수 비교 (COMPARISON OF TWO SCATTERING PHASE FUNCTIONS IN MULTIPLE SCATTERING ENVIRONMENT)

  • 선광일
    • 천문학논총
    • /
    • 제25권4호
    • /
    • pp.113-118
    • /
    • 2010
  • The Henyey-Greenstein (H-G) phase function, which is characterized by a single parameter, has been generally used to approximate the realistic dust-scattering phase function in investigating scattering properties of the interstellar dust. Draine (2003) proposed a new analytic phase function with two parameters and showed that the realistic phase function is better represented by his phase function. If the H-G and Draine's phase functions are significantly different, using the H-G phase function in radiative transfer models may lead to wrong conclusions about the dust-scattering properties. Here, we investigate whether the H-G and Draine's phase functions would indeed produce significant differences in radiative transfer calculations for two simple configurations. For the uniformly distributed dust with an illuminating star at the center, no significant difference is found. However, up to ~ 20% of difference is found when the central star is surrounded by a spherical-shell dust medium and the radiation of $\lambda$ < $2000\;{\AA}$ is considered. It would mean that the investigation of dust-scattering properties using the H-G phase function may produce errors of up to ~ 20% depending on the geometry of dust medium and the radiation wavelength. This amount of uncertainty would be, however, unavoidable since the configurations of dust density and radiation sources are only approximately available.

수직원관 주위에서 밀도차와 자연대류를 고려한 응고과정 해석 (Analysis of Solidification Process Around a Vertical Tube Considering Density Change and Natural Convection)

  • 김무근;노승탁
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.142-155
    • /
    • 1992
  • 본 연구에서는 실제 빙축열 시스템의 해석을 위한 기초 모델로서 수직원관 주 위의 응고과정에 대하여 밀도차와 자연대류 효과 및 최대 밀도점을 나타내는 밀도-온 도 관계식을 도입한 수치해석과 실험을 통하여 여러가지 매개변수들이 상변화에 미치 는 영향을 알아 보았다.

만성요통환자의 보행특성에 관한 연구 (A Study on the Characteristics of Gait in Patients with Chronic Low Back Pain)

  • 김경;고주연;이성용
    • The Journal of Korean Physical Therapy
    • /
    • 제21권2호
    • /
    • pp.79-85
    • /
    • 2009
  • Purpose: This study examined the characteristics of gait in patients with chronic low back pain. Methods: The subjects were out-patients suffering from chronic low back pain at the department of physical therapy, B hospital in Seoul. Gait analysis was performed by dividing the subjects into two groups. The study and control group comprised 15 chronic low back pain patients and 14 healthy people, respectively. Gait analysis was performed using a VICON 512 Motion Analysis System to obtain the spatio-temporal and kinematic parameters. Results: First, there was a significant difference in the spatio-temporal parameters between the two groups (p<0.05). Second, the study group showed significant differences in the kinematic parameters during the stance phase (p<0.05). Third, there were significant differences in kinematic parameters in the study group during the swing phase (p<0.05). Conclusion: The gait pattern of patients with chronic low back pain is characterized by more rigid patterns. Compared to the control group, there was a decrease in the spatio-temporal parameters and kinematic parameters in patients with chronic low back pain. These findings are expected to play a role as basic data and to form a rehabilitation program for low back pain patients.

  • PDF

소수성 파라메터를 적용한 알킬벤젠류의 역상컬럼내의 용출거동 예측 (Prediction of Retention Behavior of Alkyl Benzenes by Hydrophobicity Parameters in Reversed-Phase Column)

  • 이창영;박명용;이용문
    • 약학회지
    • /
    • 제53권5호
    • /
    • pp.281-285
    • /
    • 2009
  • The retention of solutes in reversed-phase high-performance liquid chromatography depends on their hydrophobicity. Although the retention behaviors of alkyl benzenes have been reported so far, quite a few authors have mentioned the retention behavior of alkyl benzenes with plural hydrophobicity parameters. In this sense, we were interested in the retention behaviors of alkyl benzenes having benzene moiety and increasing alkyl chain. In this study, we therefore investigated the retention behavior of alkyl benzenes in reversed-phase high-performance liquid chromatography in order to obtain information concerning the effects of the aromatic moiety and the carbon chain on the retention mechanism by comparing their capacity factor (k') in relation to the carbon chain length. The eluent acetonitrile ($CH_3CN$) showed high selectivity on alkyl benzenes, showing the high difference of capacity factor (${\Delta}log\;k'$) between toluene and octyl benzene. Indeed, the ${\Delta}log\;k'$ of 80% $CH_3CN$ represented 1.42- and 4.25-times longer than 90% MeOH and 60% THF, respectively. The hydrophobicity parameters, van der Waals volume, bond constant, partition constant, $\pi$-energy effect and enthalpy were evaluated with the capacity factor (k') of alkyl benzenes eluted on 80% CH3CN, 90% MeOH and 60% THF, respectively. The best eluent for predicting retention behavior of alkyl benzenes was 90% MeOH ($R^2$ 0.999). The three parameters, van der Waals volume, bond constant and partition constant were well coincident to log k' by increasing alkyl benzenes. However, $\pi$-energy effect and enthalpy were severely disagreeable. Taken together, van der Waals volume, bond constant and partition constant were a reliable parameters to predict the retention behaviors of alkyl benzenes on reversed-phase column.

정지신호과제의 수행에 따른 보행정지 시 다리 근전도 및 지면반발력 비교 (Comparison of Lower Extremity Electromyography and Ground Reaction Force during Gait Termination according to the Performance of the Stop Signal Task)

  • 구동균;권중원
    • PNF and Movement
    • /
    • 제20권1호
    • /
    • pp.135-145
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the association between cognitive and motor inhibition by comparing muscle activity and ground reaction force during unplanned gait termination according to reaction time measured through the stop-signal task. Methods: Sixteen young adults performed a stop-signal task and an unplanned gait termination separately. The subjects were divided into fast and slow groups based on their stop-signal reaction time (SSRT), as measured by the stop-signal task. Electromyography (EMG) and ground reaction force (GRF) were compared between the groups during unplanned gait termination. The data for gait termination were divided into three phases (Phase 1 to 3). The Mann-Whitney U test was used to compare spatiotemporal gait parameters and EMG and GRF data between groups. Results: The slow group had significantly higher activity of the tibialis anterior in Phase 2 and Phase 3 than the fast group (p <0.05). In Phase 1, the fast group had significantly shorter time to peak amplitude (TPA) of the soleus than the slow group (p <0.05). In Phase 2, the TPA of the tibialis anterior was significantly lower in the fast group than the slow group (p <0.05). In Phase 3, there was no significant difference in the GRF between the two groups (p >0.05). There were no significant difference between the two groups in the spatiotemporal gait parameters (p >0.05). Conclusion: Compared to the slow group, the fast group with cognitive inhibition suppressed muscle activity for unplanned gait termination. The association between SSRT and unplanned gait termination shows that a participant's ability to suppress an incipient finger response is relevant to their ability to construct a corrective gait pattern in a choice-demanding environment.

위전도(胃電圖)에 영향을 미치는 요인(要因)에 대한 고찰(考察) (A Review on factors that influence Electrogastrography)

  • 김선혁;박영배;박영재;오환섭
    • 대한한의진단학회지
    • /
    • 제13권1호
    • /
    • pp.10-18
    • /
    • 2009
  • Objectives : To review to determine difference in the effect of age, gender, location of electrode, test meal and period of recording that influence Electrogastrography (EGG) parameters and to study its oriental medical application. Methods : We investigate the research results through internet search engines, Pub Med, Karger, Mary Ann Libert and Pro Quest. Results : Age and gender influence postprandial Dominant Frequency Instability Coefficient (DFIC). Body mass index (BMI) influence fasting and postprandial EGG parameters. Menstrual cycle phase influence fasting Dominant Frequency (DF). Test meal volume and composition influence postprandial EGG parameters. But reduced-calorie test meal have no effect on EGG parameters. Conclusions : Because the amplitude of surface-recorded SW(slow wave) is very weak, EGG is influenced by many factors. Age, gender, BMI, menstrual cycle phase, test meal volume and test meal composition influence EGG parameters. but reduced-calorie test meal have no effect on EGG parameters.

  • PDF

배전계통연계 분산전원의 위상변화에 따른 고립운전 파라미터 특성 (A Study on Islandig Characteristics using Phase Angle Adjustment of Distributed Generation)

  • 방지윤;김학만;이복구;심재선;신명재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.525-526
    • /
    • 2006
  • Recently, much research has been done and many improvements have been developed for islanding protection of distributed generation(DG). Anti-islanding protection for DG must be act very quickly to prevent equipment damage at the time of disconnection and for the safety of maintenance and repair personnel. DG-based detection methods have included both passive and active types, and now research has shifted towards new anti-islanding detection methods that make up for the defects of the previous types. Because differences occur between the utility grid and the DG when connecting and disconnecting depending on the phase difference, voltage, current, relative capacity of electric power, and system operation characteristics, voltage phase angle is an important consideration. In this paper, we simulated islanded operation characteristics comparing phase difference of DG and the connected utility grid, and analyzed various parameters (real power, reactive power, RMS voltage, RMS current, power factor angle, and frequency) by varying the DG's voltage phase angle. Using this information, we propose a suitable DG voltage phase angle for enhanced passive islanding detection techniques.

  • PDF

기능적 전기자극이 뇌졸중 환자의 보행에 미치는 영향 (Effects of Functional Electrical Stimulation on Gait Patterns in Stroke Patient)

  • 김용욱;원종혁;정보인
    • 한국전문물리치료학회지
    • /
    • 제7권3호
    • /
    • pp.72-80
    • /
    • 2000
  • This study was to investigate the effects of a functional electrical stimulation (FES) on temporal parameters (stride length, step width and cadence) of gait patterns in a patient with right hemiparesis. A single-subject reversal (ABAB) design was used. The subject was a 25-year-old male who had foot drop and circumduction gait pattern. An ink foot-print method was used to assess the temporal parameters of gait between the baseline phase and the intervention phase. FES was applied at 8 m walkway, three times a week for 5 weeks. The results showed that stride length was increased by 4.04 cm and that step width was decreased by 3.93 cm in the intervention phase. There was no difference in cadence between the baseline phase and intervention phase.

  • PDF

4광파 혼합에 의한 선형 위상 공액 발진기의 발진조건 (The Oscillation Conditions of a Linear Phase-Conjugate Oscillator using Four-Wave Mixing)

  • 조제황;양인응
    • 대한전자공학회논문지
    • /
    • 제27권8호
    • /
    • pp.1289-1293
    • /
    • 1990
  • In this paper, the oscillation condition for the linear phase-conjugate oscillator which consists of one photorefractive crystal, two conventional mirrors, and two pump waves applied externally has been analyzed. In the result, it has been shown that the oscillation condition of this oscillator can be easily controlled by adjusting the various parameters such as the intensity ratio, polarization states, and light path difference of two pump waves, etc.

  • PDF