• 제목/요약/키워드: Phase-Average

검색결과 2,209건 처리시간 0.025초

단상 SRM의 여자구간에 따른 평균 토크 측정 (Measuring the Average Torque according to Exciting Region of Single Phase SRM)

  • 김용헌;이은웅;이종한;이현우;김준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.989-991
    • /
    • 2004
  • There are many elements that affect the average torque of the single phase SRM. It is related with the stator and rotor pole arcs, the dwell angle of the exciting current, the turn on/off angle, etc., Most of all, the turn on/off angle is affect the design procedure of the driving and control circuit. So, in this study, it is intend to analyze the effect that the variations of the turn on/off angle affects the average torque. and then this analyses will be used to design the control driver of the single phase SRM.

  • PDF

폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가 (A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment)

  • 최병걸;최창헌;윤일규;양진성;이동명;박주미
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.59-67
    • /
    • 2014
  • 목 적 : 폐암의 정위적체부방사선치료시 실제 적용하고 있는 최대강도투사(MIP) 영상과 호흡위상별(0~90%)영상에서 3차원적으로 재구성된 선량 분포 차이를 평가하고자 한다. 대상 및 방법 : 본원에서 정위적체부방사선치료를 시행한 비소세포성 폐암(NSCLC) 환자 5명을 대상으로 4차원 전산화단층영상을 시행하여 10개의 호흡위상별 영상을 획득한 후 최대강도투사 영상을 재구성하여 각 호흡위상별 치료계획을 수립하였고, 2차원 이온전리함과 선량분석프로그램 COMPASS(IBA dosimetry, Schwarzenbruck, Germany)을 이용하여 3차원적으로 재구성된 선량분포를 측정하였다. 이를 이용하여 치료계획 선량분포와 실제 측정 선량분포의 일치성 여부 및 최대강도투사 영상과 호흡위상별 영상에서 선량 분포의 차이를 정량적으로 비교 분석하였다. 결 과 : 최대강도투사 영상 및 호흡위상별 영상에서의 선량분포의 일치성을 알아보기 위한 감마분석 통과율은 대상 환자 모두 99%이상으로 평가기준을 만족 시켰으며, 각각의 환자들에 대한 최대강도투사 영상과 호흡위상별 영상에서 재구성된 선량의 HI(Homogeneity Index) 차이의 평균은 -0.03~0.04로 크지 않았으며, PTV(Planning Target Volume)의 Dmax 차이는 평균 3.30 cGy, 척수는 평균 40 cGy, 양측 폐, 우폐, 좌폐의 $V_{20}$, $V_{10}$, $V_5$ 차이는 평균 -0.04~2.32% 차이를 나타내었다. 또한 모든 환자에 대한 최대강도투사 영상과 호흡위상별 영상에서 재구성된 선량의 HI 차이의 평균은 -0.03~0.03로 크지 않았으며, PTV의 Dmax 차이의 평균은 10% 영상에서 가장 차이가 작았고, 70% 영상에서 가장 큰 차이를 나타내었다. 척수의 Dmax차이의 평균은 50% 영상에서 가장 차이가 작았고, 0% 영상에서 가장 큰 차이를 나타내었다. 폐 $V_{20}$, $V_{10}$, $V_5$의 차이의 평균은 호흡위상별로 일정한 경향성을 나타내지 않았다. 결 론 : 본 연구를 통해 최대강도투사 영상과 각 호흡위상별 영상에서 측정되어 3차원적으로 재구성된 선량분포차이는 일정한 경향을 나타내지는 않았지만 특정 호흡위상에서 선량 분포 차이가 상이한 경우를 볼 수 있었다. 종양의 위치 및 호흡 움직임이 유사한 대상환자군을 선정하여 체계적인 연구를 통해 데이터화 하게 되면 폐와 같이 움직임이 큰 장기의 정위적체부방사선치료시 특정 호흡위상에서 획득한 영상에서의 치료계획이 실제 치료에 적용되어야 하는지에 대한 적합성 여부를 판단 할 수 있을 것이라고 사료된다.

3상 직렬공진형 고전압 커패시터 충전기의 해석 및 설계 (Analysis and Design of a 3-phase Series-Resonant type High Voltage Capacitor Charger)

  • 이병하;박상은;차한주
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.510-516
    • /
    • 2013
  • This paper suggests a 3-phase series-resonant type high voltage capacitor charger for an EML pulsed power system. The operating principle on the charger is explained by an equivalent circuit. Additionally, we analyze the charging characteristic in one discontinuous conduction mode and three continuous conduction modes. The analysis shows that the resonant current per phase is two thirds of the 3-phase charger's average charging current and one third of the single-phase charger's average charging current with the same capacity. We suggest a design method of the 3-phase capacitor charger in each operational mode and present an example of 3.5 kW capacitor charger at ${\omega}_s=0.33{\omega}_r$. The 3.5 kW 3-phase capacitor charger prototype is assembled with a TI28335 controller and a 40 kJ, 7 kV capacitor. The design rules based on the analysis are verified by experiment.

비대칭 3상 3선 전원 시스템을 위한 능동전력필터의 평균전력 알고리즘 (The Average Power Algorithm of Active Power Filters for Asymmetrical Three-Phase Three-Wire Power System)

  • 정영국;김우용;임영철
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.514-524
    • /
    • 2001
  • 종전의 평균전력이론은 3상 불평형과 같은 전원전압 조건에 따라 능동전력필터의 보상기준전류가 결정적으로 영향을 받는 문제점이 있다. 이와 같은 불평형된 능동전력 필터의 보상전류는 결과적으로 불평형이 되는 원인이 된다. 본 연구에서는 불평형 전원 하에서도 유효전력과 기본파 무효전력의 동기 검출법에 입각하여 비선형 부하전류의 유효성분과 기본파 무효성분 그리고 왜형 성분을 각각 독립적으로 분해가 가능한 평균전력 이론을 제시하였다. 제안된 이론은 간단한 평균전력 이론을 기반으로 하고 잇기 때문에 우선 이해사기 쉽고 구현이 간단하다는 장점이 있다. 본 연구 에서는 고속의 DSP(digital signal processor)에 의하여 이와 같은 문제을 어느정 도 해결할 수있었다. 제안된 방법의 타당성을 입증하기 위해서 TMS320C31-DSP기반의 전력분석 시스템을 제작하였다. b상 전압이 15% 불평형된 3상 3전 전원하에서 시뮬레이션 및 실험을 수행한 결과 종전의 방법에 비하여 제안된 알고리즘의 유용성을 입증할수 있었다.

  • PDF

Effects of protease enzyme supplementation in weanling pigs' diet with different crude protein levels on growth performance and nutrient digestibility

  • Olivier, Munezero;In Ho, Kim
    • Journal of Animal Science and Technology
    • /
    • 제64권5호
    • /
    • pp.854-862
    • /
    • 2022
  • The purpose of this study is to determine the impact of different levels of crude protein (CP) diets supplemented with dietary protease on the growth performance and nutrient digestibility of the weanling pigs. In a 5-week study, 100 crossbred ([Landrace × Yorkshire] × Duroc) of weaner pigs that have an average initial body weight (BW) of 7.17±1.06 kg were assigned to one of four dietary treatments with 5 replications and 5 pigs (3 gilts and 2 castrated male pigs) per pen in a randomized complete block design. The dietary treatments were as follows: Phase 1: CON: basal diets (20.60% CP); low protein (LP): CON - 0.30% CP; PLP1: (CON - 0.30% CP) + 0.05% protease; PLP2: (CON - 0.50% CP) + 0.05% protease. Phase 2: CON: basal diets (18.88% CP); LP: CON - 0.30% CP; PLP1: (CON - 0.30% CP) + 0.05% protease; PLP2: (CON - 0.50% CP) + 0.05% protease. The addition of protease to low CP diets significantly increased the feed conversion ratio (FCR) (p = 0.039), BW (p = 0.046), average daily gain (ADG) (p = 0.049), and average daily feed intake (ADFI) tended to increase (p = 0.053) in the young pigs during phase 1. However, FCR tended to increase throughout the experiment but did not change during phase 2, whereas BW, ADG, and ADFI stayed unchanged throughout phase 2 and overall. There was no significant difference in dry matter, nitrogen (N), and gross energy of nutrient digestibility in all phases and overall in weaned pigs with low CP when protease was fed. In contrast, adding protease to the low CP diets increased the tendency of N digestibility (p = 0.059) during phase 1. It is concluded that dietary protease supplementation tended to increase N retention during the first phase of the weaning period, hence increasing piglet performance.

Effect of reducing dietary crude protein level on growth performance, blood profiles, nutrient digestibility, carcass traits, and odor emissions in growing-finishing pigs

  • Aaron Niyonsaba;Xing Hao Jin;Yoo Yong Kim
    • Animal Bioscience
    • /
    • 제36권10호
    • /
    • pp.1584-1595
    • /
    • 2023
  • Objective: This study was conducted to evaluate the effect of a low-protein diet on growth performance, carcass traits, nutrient digestibility, blood profiles, and odor emissions in growing-finishing pigs. Methods: A total of 126 crossbred pigs ([Yorkshire×Landrace]×Duroc) with an average body weight (BW) of 38.56±0.53 kg were used for a 14-week feeding trial. Experimental pigs were allotted to one of 6 treatments in 3 replicates of 7 pigs per pen in a randomized complete block design. Pigs were fed each treatment diet with different levels of crude protein (CP). Phase 1 (early growing): 14%, 15%, 16%, 17%, 18%, 19%; phase 2 (late growing): 13%, 14%, 15%, 16%, 17%, 18%; phase 3 (early finishing): 12%, 13%, 14%, 15%, 16%, 17%; phase 4 (late finishing): 11%, 12%, 13%, 14%, 15%, 16%. All experimental diets in each phase were contained the same concentration of lysine (Lys), methionine (Met), threonine (Thr), and tryptophan (Trp). Results: Over the entire experimental period, there was no significant difference in BW, average daily feed intake, and gain-to-feed ratio among all treatments (p>0.05), but a quadratic effect (p = 0.04) was observed in average daily gain (ADG) during the late finishing phase with higher ADG in Group D. Blood urea nitrogen concentration linearly increased with an increase in dietary CP levels (p<0.01). Regarding nutrient digestibility, excreted nitrogen in urine and feces and nitrogen retention linearly increased as the CP level increased (p<0.01). A linear effect was observed with increasing CP levels in amines, ammonia, and hydrogen sulfide in odor emissions (p<0.01). No significant effects were observed in the measurements of carcass traits and meat characteristics (p>0.05). Conclusion: In phase feeding, reducing the CP level to 14% in early-growing pigs, 13% in late-growing pigs, 12% in early-finishing pigs, and 11% in late-finishing pigs is recommended.

Counter-Current Air-Water Flow in Narrow Rectangular Channels With Offset Strip Fins

  • Kim, Byong-Joo;Sohn, Byung-Hu;Koo, Kee-Kahb
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.429-439
    • /
    • 2003
  • Counter-current two-phase flows of air- water in narrow rectangular channels with offset strip fins have been experimentally investigated in a 760 mm long and 100 mm wide test section with 3.0 and 5.0 mm gap widths. The two-phase flow regime, channel-average void fractions and two-phase pressure gradients were studied. Flow regime transition occurred at lower superficial velocities of air than in the channels without fins. In the bubbly and slug flow regimes, elongated bubbles rose along the subchannel formed by fins without lateral movement. The critical void fraction for the bubbly-to-slug transition was about 0.14 for the 3 mm gap channel and 0.2 for the 5 mm gap channel. respectively. Channel-average void fractions in the channels with fins were almost the same as those in the channels without fins. Void fractions increased as the gap width increased, especially at high superficial velocity of air. The presence of fins enhanced the two-phase distribution parameter significantly in the slug flow, where the effect of gap width was almost negligible. Superficial velocity of air dominated the two-phase pressure gradients. Liquid superficial velocity and channel gap width has only a minor effect on the pressure gradients.

배터리 충·방전기 시스템에 적용되는 3상 양방향 절연형 인터리브드 DC-DC 컨버터의 병렬운전 (Parallel Operation of Three-Phase Bi-Directional Isolated Interleaved DC-DC Converters for The Battery Charge/Discharge System)

  • 조현식;이재도;차한주
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Recently, parallel operation of dc-dc converters has been widely used in distributed power systems. In this paper, a control method to achieve parallel operation of three-phase bi-directional isolated interleaved dc-dc converters is discussed for the battery charging and discharging system which consists of the 32 battery charger/dischargers and two three-phase bi-directional isolated interleaved dc-dc converters. In the boost mode, the battery energy is delivered to the grid, whereas the grid energy is transferred to the battery in the buck mode operation. The average current sharing control method is employed to obtain an equal conducting of each phase current in the three-phase dc-dc converter. By using the proposed method, the imbalance factor is gratefully reduced from 8 percent to 1 percent. Two 2.5kW three-phase bi-directional dc-dc converter prototype have been built and the proposed method has been verified through experiments.

와추적 위상평균 기법을 이용한 원주후류의 PIV측정 (PIV Measurement of Circular Cylinder Wake Using Vortex Tracking Phase-Average Technique)

  • 김경천;윤상열;김상기;부정숙
    • 대한기계학회논문집B
    • /
    • 제25권7호
    • /
    • pp.915-922
    • /
    • 2001
  • A new phase-average technique using instantaneous velocity fields obtained by a PIV method has been developed. The technique tracks vorticity centers and estimates the value of circulation for a chosen domain. The locations of vortex-centers and the magnitudes of circulation are matched together then showing a sine wave feature due to the periodic vortex shedding from the circular cylinder. Ensemble averaged and phase averaged velocity fields are successfully measured for the circular cylinder wake where Reynolds number is 3900 based on free stream velocity and cylinder diameter. The convection velocities of the vortices center and the vortex shedding frequency were measured by a single hot-wire probe.

Experimental Study on Two-Phase Flow Parameters of Subcoolet Boiling in Inclined Annulus

  • Lee, Tae-Ho;Kim, Moon-Oh;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.29-48
    • /
    • 1999
  • Local two-phase flow parameters of subcooled flow boiling in inclined annulus were measured to investigate the effect of inclination on the internal flow structure. Two-conductivity probe technique was applied to measure local gas phasic parameters, including void fraction, vapor bubble frequency, chord length, vapor bubble velocity and interfacial area concentration. Local liquid velocity was measured by Pilot tube. Experiments were conducted for three angles of inclination; 0$^{\circ}$(vertical), 30$^{\circ}$, 60$^{\circ}$. The system pressure was maintained at atmospheric pressure. The range of average void fraction was up to 10% and the average liquid superficial velocities were less than 1.3 m/sec. The results of experiments showed that the distributions of two-phase How parameters were influenced by the angle of channel inclination. Especially, the void fraction and chord length distributions were strongly affected by the increase of inclination angle, and flow pattern transition to slug flow was observed depending on the How conditions. The profiles of vapor velocity, liquid velocity and interfacial area concentration were found to be affected by the non-symmetric bubble size distribution in inclined channel. Using the measured distributions of local phasic parameters, an analysis for predicting average void fraction was performed based on the drift flux model and flowing volumetric concentration. And it was demonstrated that the average void fraction can be more appropriately presented in terms of flowing volumetric concentration.

  • PDF