• Title/Summary/Keyword: Phase variation

Search Result 2,038, Processing Time 0.034 seconds

A Study on the Fabrication of Superconductor Using Pyrolysis Methods for Electric power Machinery (열분해법에 의한 전력기기용 초전도 합성 기술에 관한 연구)

  • Lee, Sang-Heon;Lee, Young-Hie
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.153-154
    • /
    • 2005
  • A high Tc superconducting with a nominal composition of $Bi_2Sr_2Ca_2Cu_3O_Y$ was prepared by the citarte method. The solid precursor produced by the dehydration of the gel at 120$^{\circ}C$ for 12h is not in the amorphous state as expected but in a crystalline state. X-ray diffraction peaks of nearly the same angular position as the peaks of high Tc phase were observed in the precursor. After pyrolysis at 400$^{\circ}C$ and calcination at 840$^{\circ}C$ for 4h, the (001)peak of the high Tc phase was cleary observed. Experimental results suggest that the intermediate phase formed before the formation of the superconducting phase may be the most important factro in determining whether it is easy to form the high Tc phase or not, because the nucleation barriers of the two superconducting phase may be altered by the variation of the crystal structures of those intermediate phase.

  • PDF

A Switching Method for Minimizing the Over Current in Transient Response of 3-phase Interleaved Bidirectional DC-DC Converter with Frequency Modulation (주파수 변조 방식 3상 인터리브드 양방향 DC-DC 컨버터의 과도상태 과전류를 최소화하기 위한 스위칭 기법)

  • Bae, Jongwoo;Jeong, Hyesoo;Jung, Jae-Hun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.530-537
    • /
    • 2016
  • This work deals with a switching method for minimizing overcurrent in a three-phase interleaved bidirectional DC-DC converter with frequency modulation. Generally, a three-phase interleaved DC-DC converter is used to reduce a current ripple component. The combined operation of three-phase and two-phase converters can significantly reduce the ripple component. However, the conventional PWM method cannot solve severe overcurrent during phase transfer or frequency variation for power control. To overcome this problem, this work proposes a new PWM switching method. A 3 kW DC-DC power converter is designed and implemented, and the converter is operated in discontinuous current mode with varying switching frequencies for power control. Simulation and experimental results show the validity of the proposed switching method. The proposed switching method can be widely used in the field of current ripple reduction for three-phase interleaved bidirectional DC-DC converters.

Influence of Notch Change on Corrosion Fatigue Fracture in F.E.M. Dual phase Steel of SS41 Steel (SS41강의 F.E.M.복합조직강에서 노치변화가 부식피로파괴에 미치는 영향)

  • 도영민;이규천
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.44-50
    • /
    • 2001
  • The rotated bending fatigue test was conducted in air md in 3.5% NaCl salt solution to investigate the fatigue fracture behaviour of raw material and F.E.M dual phase steel made from raw material(SS41) by a suitable heat treatment. This study has compared the initial microcrack creation of material by tensile test with that by fatigue test. And the rotated bending test of cantilever type under the condition of 3.5% NaCl salt solution and air has investigated the corrosion fatigue fracture behaviour with the variation of stress concentration factor determined by each of notch shapes. The initial microcrack have been developed in fragile grainboundary with general corrosion occurring in raw material : in the pits built up by corrosion in F.E.M. dual phase steel because pits bring out stress concentration. It is small that the degree of decrease in corrosion fatigue life for F.E.M. dual phase steel compared with raw material because the notch sensitivity of F.E.M. dual phase steel is lower than raw material in reason of characteristics with two-phase construction.

  • PDF

Synthesis of high functional Superconducting Precursor using Organic metal salts method for Electric power transmission (유기금속염을 이용한 고효율 전력 전송용 초전도 전구체 합성)

  • Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.270-271
    • /
    • 2005
  • A high Tc superconducting with a nominal composition of $Bi_2Sr_2Ca_2Cu_3O_Y$ was prepared by the citarte method. The solid precursor produced by the dehydration of the gel at $120^{\circ}C$ for 12h is not in the amorphous state as expected but in a crystalline state. X-ray diffraction peaks of nearly the same angular position as the peaks of high Tc phase were observed in the precursor. After pyrolysis at $400^{\circ}C$ and calcination at $840^{\circ}C$ for 4h, the (001)peak of the high Tc phase was cleary observed. Experimental results suggest that the intermediate phase formed before the formation of the superconducting phase may be the most important factro in determining whether it is easy to form the high Tc phase or not. because the nucleation barriers of the two superconducting phase may be altered by the variation of the crystal structures of those intermediate phase.

  • PDF

3-Phase RMS Voltage Measurement Method of Virtual Frequence using Instantaneous Power Component Concept (순시전력 합성 개념을 이용한 가상주파수 3상 실효전압 계측기법)

  • Park, Seong-Mi;Yang, Ji-Hoon;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.3
    • /
    • pp.251-257
    • /
    • 2019
  • This paper proposes a new measurement method using virtual power concept to measure the effective value of 3-phase voltage with variable frequency. The conventional effective value measurement method uses a method of integrating data sampled during one or half cycle of the power voltage and averaging it. In this method, since the effective voltage is calculated every cycle, a time delay occurs in the measured effective voltage and it is s a problem to measure the effective value of a device whose frequency varies from time to time, such as a generator. The proposed 3-phase voltage rms measurement method has an advantage that it can measure accurate voltage RMS value regardless of measurement frequency variation. In particular, there is an advantage in that it is possible to measure a 3-phase effective voltage rather than an average value of the effective voltage of each phase in a 3-phase unbalance voltage. In addition, the validity of the proposed method is verified by using the Psim simulation tool and the experimental results are analyzed by applying the proposed measurement algorithm to the actual three phase synchronous generator voltage measurement experiment.

Experimental study on single- and two-phase flow behaviors within porous particle beds

  • Jong Seok Oh;Sang Mo An;Hwan Yeol Kim;Dong Eok Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1105-1117
    • /
    • 2023
  • In this study, the pressure drop behavior of single- and two-phase flows of air and water through the porous beds filled with uniform and non-uniform sized spherical particles was examined. The pressure drop data in the single-phase flow experiments for the uniform particle beds agreed well with the original Ergun correlation. The results from the two-phase flow experiments were analyzed using numerical results based on three types of previous models. In the experiments for the uniform particle beds, the data on the two-phase pressure drop clearly showed the effect of the flow regime transition with a variation in the gas flow rate under stagnant liquid condition. The numerical analyses indicated that the predictability of the previous models for the experimental data relied mainly on the sub-models of the flow regime transitions and interfacial drag. In the experiments for the non-uniform particle beds, the two-phase pressure loss could be predicted well with numerical calculations based on the effective particle diameter. However, the previous models failed to accurately predict the counter-current flooding limit observed in the experiments. Finally, we propose a relation of falling liquid velocity into the particle bed by gravity to appropriately simulate the CCFL phenomenon.

GENERAL FAMILIES OF CHAIN RATIO TYPE ESTIMATORS OF THE POPULATION MEAN WITH KNOWN COEFFICIENT OF VARIATION OF THE SECOND AUXILIARY VARIABLE IN TWO PHASE SAMPLING

  • Singh Housila P.;Singh Sarjinder;Kim, Jong-Min
    • Journal of the Korean Statistical Society
    • /
    • v.35 no.4
    • /
    • pp.377-395
    • /
    • 2006
  • In this paper we have suggested a family of chain estimators of the population mean $\bar{Y}$ of a study variate y using two auxiliary variates in two phase (double) sampling assuming that the coefficient of variation of the second auxiliary variable is known. It is well known that chain estimators are traditionally formulated when the population mean $\bar{X}_1$ of one of the two auxiliary variables, say $x_1$, is not known but the population mean $\bar{X}_2$ of the other auxiliary variate $x_2$ is available and $x_1$ has higher degree of positive correlation with the study variate y than $x_2$ has with y, $x_2$ being closely related to $x_1$. Here the classes are constructed when the population mean $\bar{X}_1\;of\;X_1$ is not known and the coefficient of variation $C_{x2}\;of\;X_2$ is known instead of population mean $\bar{X}_2$. Asymptotic expressions for the bias and mean square error (MSE) of the suggested family have been obtained. An asymptotic optimum estimator (AOE) is also identified with its MSE formula. The optimum sample sizes of the preliminary and final samples have been derived under a linear cost function. An empirical study has been carried out to show the superiority of the constructed estimator over others.

A Study on Improving Mass Production of the Radar Sensor Oscillator (레이더 센서용 발진기의 양산성 향상에 관한 연구)

  • Kim, Byung-Chul;Cho, Kyung-Rae;Lee, Jae-Buom;Kim, Dae-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.669-676
    • /
    • 2012
  • In this paper, The method to improve the mass production method of the radar sensor is suggested by using the temperature compensation circuit which is composed with the thermister. The mass production became easier by decreasing the adjustment time for the exact oscillation frequency with the temperature compensation circuit that can support the proper gate bias voltage for the FET after the dielectric resonator is removed from the DRO(Dielectric Resonator Oscillator) of the radar sensor. Radar sensor with the proposed method has 15.67MHz oscillator frequency variation in the temperature range of $-20^{\circ}C-+55^{\circ}C$, 0.65dB magnitude variation, -105.47dBc phase noise characteristics at 1MHz which are better or similar temperature characteristics with the DRO whose oscillator frequency variation is 25MHz, magnitude variation is 0.42dB and phase noise is -107.40dBc in the same temperature range.

Effect of varying the coupling strength and section length on the self-pulsation characteristics of multisection index-coupled DFB lasers (다중 전극 Index-Coupled DFB 레이저에서 결합 세기 및 각 영역의 길이가 Self-Pulsation 동작 특성에 미치는 영향)

  • Kim, Sang-Taek;Kim, Tae-Young;Ji, Sung-Keun;Kim, Boo-Gyoun
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.85-98
    • /
    • 2005
  • As the number of compound cavity modes within the stopband of DFB sections decreases, the frequency of mode hopping decreases for the variation of $\Delta$λ$_{B}$, which represents the difference between the Bragg wavelengths of two DFB sections, so that the number of abrupt changes of pulsation frequencies decreases. In addition, the pulsation frequency varies continuously for the variation of the phase in a phase tuning section for a fixed $\Delta$λ$_{B}$. The number of compound cavity modes within the stopband decreases as the length of DFB sections increases and the length of a phase tuning section decreases. Thus stable self-pulsation operations for the variation of $\Delta$λ$_{B}$ and the phase in a phase tuning section could be obtained by proper selection of the coupling strength and the length of each section.ction.

Kinetic analysis of the lower limb in visual handicap children (시각장애 아동의 보행 시 하지의 운동역학적 분석)

  • Yi, Jae-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.3952-3958
    • /
    • 2011
  • This study was to investigate the difference in gait pattern between the visual handicap children and non handicap children in by analyze the biomechanical variation and pattern of lower limb. Therefore, we have made a choice of four visually handicapped children and two subjects, who had no medical disorder for the last six months. In order to collect the gait pattern data of each group, we have used six infrared cameras and one forceplate Also, we have used QTM program to collect the raw data and Visual3D program to calculate kinetic variable. The results were as follows, An/Posterior GRF of breaking phase and propulsion phase in stance phase was lower in visual handicapped children than that of non handicapped children and breaking phase was longer than propulsion phase. extension moment at the ankle was quite lower than general gait pattern and there was little variation at the knee joint which makes the results differ from the general gait pattern. However, hip joint moment was relatively higher than that of other joints. Mechanical variation of lower limb, in case of foot and shank, showed similar results. but generated very low mechanical energy. In thigh, the form of mechanical energy generation was slightly different in each group but generated more mechanical energy than other segments.