• Title/Summary/Keyword: Phase potential

Search Result 1,919, Processing Time 0.022 seconds

Uncertainty Analysis in Potential Transformer Calibration Using a High Voltage Capacitance Bridge

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Kwon, Sung-Won;Kim, Myung-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.401-407
    • /
    • 2007
  • Precise absolute measurement of the errors in a potential transformer (PT) can be achieved using high voltage capacitance bridge (HVCB) and capacitive divider. The uncertainty in a PT measurement using the HVCB system was evaluated by considering the overall factors affecting during the calibration of a PT. The expanded uncertainties are found to be not more than $30{\times}10^{-6}$ for ratio and $30{\mu}rad$ for phase up to the primary voltage of $V_p=22kV$. For same PTs, the measured errors in KRISS (Korea Research Institute of Standards and Science) using our bridge are well coincide with those in NMIA (National Measurement Institute of Australia) and PTB (Physikalisch-Technische Bundesanstalt) within the corresponding uncertainties.

Simplified SVPWM that Integrates Overmodulation and Neutral Point Potential Control

  • Zhu, Rong-Wu;Wu, Xiao-Jie
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.926-936
    • /
    • 2014
  • A simplified and effective space vector pulse-width modulation (SVPWM) algorithm with two and three levels for three-phase voltage-source converters is proposed in this study. The proposed SVPWM algorithm only uses several linear calculations on three-phase modulated voltages without any complicated trigonometric calculations adopted by conventional SVPWM. This simplified SVPWM also avoids choosing the vector sector required by conventional SVPWM. A two-level overmodulation scheme is integrated into the proposed two-level SVPMW to generate the output voltage that increases from a linear region to a six-step state with a smoothly linear transition characteristic and a simple overmodulation process without a lookup table and complicated nonlinear functions. The three-level SVPWM with a proportional-integral controller effectively balances the neutral point potential of the neutral point clamped converter. Results from the simulation in MATLAB/Simulink and the experiment based on a digital signal processor are provided to clearly demonstrate the validity and effectiveness of the proposed strategies.

Simulation of electron tunneling time through a potential barrier (전위 장벽에 대한 전자의 터널링 시간의 시뮬레이션)

  • Lee, Wook;Lee, Byoung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.159-163
    • /
    • 1996
  • Simulated electron tunneling time through a potential barrier is compared with theoretical phase time. For a GaAs/Al/sub 0.3/Ga/sub 0.7/As/GaAs potential barrier with 300 meV height and 3 nm or 5 nm width, simulations are performed with various average electron energies and momentum deviations. The simulation results become closer to the theoretical phase time as the average electron energy decreases and as the momentum deviation decreases. It is also shown that a barrier, which is due to the peak spectrum shift in the momentum space after tunneling. (author). refs., figs.

  • PDF

Electron Tunneling Time through a Single Potential Barrier (하나의 전위장벽에 대한 전자의 터널링 시간)

  • Lee, Wook;Lee, Byoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1262-1264
    • /
    • 1995
  • The question-"How fast a electron tunnels a potential barrier?" looks like simple, but is controversy for more than 40 years. Because "tunneling" involves complicated internal processes and its definition is ambiguous. Recent experiments showed that the phase time is the best model of tunneling time among other times-for example, dwell time, Larmor clock time etc. In this paper, we simulated the tunneling time for Gaussian wave packet by program InterQuanta and compared with the phase time. In particular we focused on the effect of wave packet spreading in momentum space(or real space) which is not expressed by the phase time formula.

  • PDF

Molecular Dynamics Simulation of First-Order Phase Transition (일차 상변화 과정의 분자 동력학적 모사)

  • Lee, Jae-Yeon;Yoon, Woong-Sup
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.161-166
    • /
    • 2004
  • A study of argon droplet vaporization is conducted using molecular dynamics. Instead of using traditional method such as the Navier-Stokes equation. Molecular dynamics uses Lagrangian frame to describe molecular behavior in a system and uses only momentum and position data of all molecules in the system. So every property is not a hypothetical input but a statistical result calculated from the momentum and position data. This work performed a simulation of the first-order stability for phase transition of a three dementional submicron argon droplet within quiescent environment. Lennard-Jones 12-6 potential function is used as a intermolecular potential function. The molecular configuration is examined while an initially non-sperical droplet is changed into the spherical shape and droplet evaporates or condensates.

  • PDF

Vapor Phase Mercury Removal by Sulfur Impregnated Activated Carbons and Sulfur Impregnation Protocol

  • Lee, Si-Hyun;Cha, Sun-Young;Park, Yeong-Seong
    • Carbon letters
    • /
    • v.2 no.1
    • /
    • pp.37-43
    • /
    • 2001
  • Mercury has been identified as a potential health and environmental hazardous material. Activated carbon adsorption offers promising potential for the control of mercury emissions, and sulfur impregnated (sulfurized) activated carbons has been shown to be an effective sorbent for the removal of vapor phase $Hg{\circ}$ from sources. In this work, vapor phase mercury adsorption by sulfur impregnated activated carbons were investigated. Sulfur impregnated activated carbons were made by variation of impregnation temperature, and the comparison of adsorption characteristics with commercial virgin and sulfurized carbons were made. Factors affecting the adsorption capacity of virgin and sulfurized activated carbons such as pore characteristics, functional groups and sulfur impregnation conditions were discussed. It was found that the sulfur allotropes plays a critical role in adsorption of mercury vapor by sulfurized activated carbons.

  • PDF

Early-Phase SPECT/CT for Diagnosing Osteomyelitis: A Retrospective Pilot Study

  • Soo Jin Lee;Kyoung Sook Won;Hyung Jin Choi;Yun Young Choi
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.604-611
    • /
    • 2021
  • Objective: The aim of this pilot study was to investigate the potential of early-phase single-photon emission computed tomography (SPECT)/computed tomography (CT) using technetium-99m methyl diphosphonate (99mTc-MDP) for diagnosing osteomyelitis (OM). Materials and Methods: Twenty-one patients with suspected OM were enrolled retrospectively. Three-phase bone scan (TPBS), early-phase SPECT/CT (immediately after blood pool planar imaging), and delayed-phase SPECT/CT (immediately after delayed planar imaging) were performed. The final diagnoses were established through surgery or clinical follow-up for over 6 months. We compared three diagnostic criteria based on (I) TPBS alone, (II) combined TPBS and delayed-phase SPECT/CT, and (III) early-phase SPECT/CT alone. Results: OM was diagnosed in 11 of 21 patients (nine surgically and two clinically). Of the 11 OM patients, criterion-I, criterion-II, and criterion-III were positive in six, seven, and 10 patients, respectively. Of the 10 non-OM patients, criterion-I, criterion-II, and criterion-III were negative in five, five, and seven patients, respectively. The sensitivity/specificity/accuracy of criterion-I, criterion-II, and criterion-III for diagnosing OM were 54.5%/50.0%/55.0%, 63.6%/50.0%/57.1%, and 90.9%/70.0%/87.5%, respectively. Conclusion: This pilot study demonstrated the potential of using the early-phase SPECT/CT to diagnose OM. Based on the results, prospective studies with a larger sample size should be conducted to confirm the efficacy of early-phase SPECT/CT.

Optimum signal setting based on phase sequence and interval in an isolated intersection (교통신호의 페이스순서 및 페이스간격을 고려한 신호최적화)

  • 김경철;임강원
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.2
    • /
    • pp.45-58
    • /
    • 1996
  • In a large signal intersection, it is the most important to set phase sequences and phase intervals of traffic signal in order to improve the efficiency of the capacity as well as safety. These setting allows to select the best sequence of signal phase among several alternatives, and thus to rearrange the starting and ending points of the individual phase using an effective interphase periods (EIP). The EIP is a gap between previous and current traffic movements at a potential collision point in an intersection. Each of traffic movements has an equality for safety and efficiency at the balanced condition of EIP. This paper presents how to set optimally the phase sequences and intervals of traffic signal in an intersection using phase based approach. And in the second part, we applied the theory developed in the first part. In particular, a numerical example of phase base signal setting is presented using a matrix computation method in order to select the best sequence among several alternatives, and thus to rearrange the starting and ending points of the individual phase using the EIP. This method also allows to apply to optimum signal setting even in five-lag or staggered-type intersection.

  • PDF

Analyses on the recriticality and sub-critical boron concentrations during late phase of a severe accident of pressurized water reactors

  • Yoonhee Lee;Yong Jin Cho;Kukhee Lim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3241-3251
    • /
    • 2023
  • The potential for recriticality and sub-critical boron concentrations is analyzed during the relocation of the fuel rods in the assembly, which we call late phase of a severe accident, via coupling between MELCOR and whole-core Monte Carlo analyses by Serpent 2. The recriticality, initiated during the early phase, is found to maintain when the fuel assemblies containing intact fuel rods are submerged by the cooling water. It is also found that the effect of the negative reactivity insertion via remaining fission products in the fuel debris increases as the burnup increases. The sub-critical boron concentrations during the late phase are found to be 76~544 ppm lower than those during the early phase. Therefore, it can be concluded that the boron concentration that prevents recriticality not only during the early phase but also during the late phase is the sub-critical boron concentration during the early phase.

LNAPL Detection with GPR (GPR 탐사방법을 이용한 유류오염물질(LNAPL) 탐지)

  • Kim, Chang-Ryol
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2001.09a
    • /
    • pp.94-103
    • /
    • 2001
  • An experiment was conducted using a sand and gravel-filled tank model, to investigate the influence on the GPR response of vadose zone gasoline vapor phase effects and residual gasoline distributed by a fluctuating water table. After background GPR measurements were made with only water in the tank, gasoline was injected into the bottom of the model tank to simulate a subsurface discharge from a leaking pipe or tank. Results from the experiment show the sensitivity of GPR to the changes in the moisture content and its effectiveness for monitoring minor fluctuation of the water table. The results also demonstrate a potential of GPR for detecting possible vapor phase effects of volatile hydrocarbons in the vadose zone as a function of time, and for detecting the effects of residual phase of hydrocarbons in the water saturated system. In addition, the results provide the basis for a strategy that has the potential to successfully detect and delineate LNAPL contamination at field sites where zones of residual LNAPL in the water saturated system are present in the subsurface.

  • PDF