• Title/Summary/Keyword: Phase image analysis

Search Result 395, Processing Time 0.023 seconds

Sheet fabrication of Ni-WC anode for Molten Carbonate Fuel Cell by Tape Casting Method (테이프 캐스팅법에 의한 MCFC Anode용 Ni-WC 박판 제조)

  • Choe, Jin-Yeong;Jeong, Seong-Hoe;Jang, Geon-Ik
    • Korean Journal of Materials Research
    • /
    • v.10 no.10
    • /
    • pp.715-720
    • /
    • 2000
  • By the mechanical alloying method. Ni-WC composite materials were prepared to improve the deformation-resistance for creep and sintering of Ni-anode at the operating temperature of $650^{\circ}C$. Mechanically alloyed powder w was initially fabricated by ball milling for 80hr, and then amorphization was occurred by the destruction of ordered crystals based on XRD analysis. In order to investigate the electrochemical performance and sheet characteristics of Ni-WC anode, tape casting process was adopted. Finally, the obtained sheet thickness of Ni- we after sintering at $1180^{\circ}C$ for 60 minutes in $H_2$ atmosphere was O.9mm and the average pore size was $3~5{\mu\textrm{m}}$ with porosities of 55%. The second phase was not observed in Ni- W matrix while W particles were finely and uniformly distributed in Ni matrix. This fine and uniform distributed W particles in Ni matrix are expected to enhance the mechanical properties of Ni anode through the dispersion and solid solution hardening mechanisms.

  • PDF

Cone-beam computed tomography-guided three-dimensional evaluation of treatment effectiveness of the Frog appliance

  • Li, Mujia;Su, Xiaoxia;Li, Yang;Li, Xianglin;Si, Xinqin
    • The korean journal of orthodontics
    • /
    • v.49 no.3
    • /
    • pp.161-169
    • /
    • 2019
  • Objective: To evaluate the effectiveness of the Frog appliance in three dimensions by using cone-beam computed tomography (CBCT) images. Methods: Forty patients (21 boys and 19 girls), averaged 11.7 years old, with an Angle Class II division 1 malocclusion were included in our study. They had either late mixed dentition or early permanent dentition, and the maxillary second molars had not yet erupted. All patients underwent CBCT before and after the treatment for measuring changes in the maxillary first molars, second premolars, central incisors, and profile. Paired-samples t-test was used to compare the mean difference in each variable before treatment and after the first phase of treatment. Results: The maxillary first molars were effectively distalized by 4.25 mm (p < 0.001) and 3.53 mm (p < 0.05) in the dental crown and root apex, respectively. The tipping increased by $2.25^{\circ}$, but the difference was not significant. Moreover the teeth moved buccally by 0.84 mm (p < 0.05) and 2.87 mm (p < 0.01) in the mesiobuccal and distobuccal cusps, respectively, whereas no significant changes occurred in the root apex. Regarding the anchorage parts, the angle of the maxillary central incisor's long axis to the sella-nasion plane increased by $2.76^{\circ}$ (p < 0.05) and the distance from the upper lip to the esthetic plane decreased by 0.52 mm (p = 0.01). Conclusions: The Frog appliance effectively distalized the maxillary molars with an acceptable degree of tipping, distobuccal rotation, and buccal crown torque, with only slight anchorage loss. Furthermore, CBCT image demonstrated that it is a simple and reliable method for three-dimensional analysis.

A Study on the Epic Expression of Multimedia and Contemporary Art (동시대 미술에서의 서사 표현 작품 분석 연구)

  • Choi, Jung-Hwa
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.553-563
    • /
    • 2022
  • In the multimedia era and contemporary art, the expression of narrative is expanding in various ways based on formal theory. And the expression form is maximized according to the use of each medium. In terms of understanding artworks, an approach that combines various expressions and media using these narratives is also possible. Therefore, this study analyzed the works of the artists by selecting three artists, Sadic Guissi Alfrazi, Lindsay Sears, and Kara Walker, who fused the media using narrative structures. Through this, it was intended to present the artistic value and significance of the work and the possibility of expanding the narrative expression of contemporary art in the future. As a result of the analysis of previous artists' works, it was shown that the phase of convergence can be derived by using the medium of narrative concepts beyond the dichotomy of content and form, confirming that digital technology and media development are changing the form of art. In addition, it was confirmed that the use of narrative structure facilitates media conversion. It is expected that discussions on the new paradigm of contemporary art will progress in the future.

Evaluation of Validity Glomerular Filtration Rate Measured by Gates Method according Region of Interest (관심 영역 설정에 따른 Gates법 토리여과율의 유효성 평가)

  • Su-Young Park;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.417-425
    • /
    • 2023
  • The glomerular filtration rate (GFR) has been the subject of much research as a key indicator for diagnosing, treating, and monitoring kidney function. The gamma camera method (Gates method) is simple and allows simultaneous acquisition of GFR and renal scintigraphy for each kidney, however its accuracy is inferior. This study aimed to investigate changes in GFR depending on how region of interest (ROI) are set up, which is one of many factors influencing accuracy. GFR was calculated by setting the ROI for each phase of the image acquisition time (Gates-1: 0~1 minutes, Gates-2: 1~3 minutes, Gates-3: 3~27 minutes), and statistical significance was verified based on probability value 0.05 through ANOVA analysis. While there was no statistically significant difference among results from Gates-1, 2, 3 (p=0.481>0.05), overall results from the Gates method tended to overestimate compared to those from the multiple blood sampling-dual exponential (MBSDE) method. When comparing averages between phases, results from Gates-2 were most similar to those from the MBSDE method. Moreover, paired t-test p-values between MBSDE method and phases were as follows Gates-1: 0.021 (p<0.05), Gates-2: 0.280 (p>0.05), and Gates-3: 0.164 (p>0.05) indicating that only Gates-1 had statistically significant differences compared with MBSDE method. Thus, setting ROI around 2~3 minutes is calculated can aid in accurately determining GFR when Gates Method.

Evaluation and Prediction of Post-Hepatectomy Liver Failure Using Imaging Techniques: Value of Gadoxetic Acid-Enhanced Magnetic Resonance Imaging

  • Keitaro Sofue;Ryuji Shimada;Eisuke Ueshima;Shohei Komatsu;Takeru Yamaguchi;Shinji Yabe;Yoshiko Ueno;Masatoshi Hori;Takamichi Murakami
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.24-32
    • /
    • 2024
  • Despite improvements in operative techniques and perioperative care, post-hepatectomy liver failure (PHLF) remains the most serious cause of morbidity and mortality after surgery, and several risk factors have been identified to predict PHLF. Although volumetric assessment using imaging contributes to surgical simulation by estimating the function of future liver remnants in predicting PHLF, liver function is assumed to be homogeneous throughout the liver. The combination of volumetric and functional analyses may be more useful for an accurate evaluation of liver function and prediction of PHLF than only volumetric analysis. Gadoxetic acid is a hepatocyte-specific magnetic resonance (MR) contrast agent that is taken up by hepatocytes via the OATP1 transporter after intravenous administration. Gadoxetic acid-enhanced MR imaging (MRI) offers information regarding both global and regional functions, leading to a more precise evaluation even in cases with heterogeneous liver function. Various indices, including signal intensity-based methods and MR relaxometry, have been proposed for the estimation of liver function and prediction of PHLF using gadoxetic acid-enhanced MRI. Recent developments in MR techniques, including high-resolution hepatobiliary phase images using deep learning image reconstruction and whole-liver T1 map acquisition, have enabled a more detailed and accurate estimation of liver function in gadoxetic acid-enhanced MRI.

A Study on the Product Design Case Study of Differential Design Concept (차별화 된 디자인 개념의 제품디자인 사례 연구)

  • 이덕상;한세준;김홍규;조철희
    • Archives of design research
    • /
    • v.17 no.2
    • /
    • pp.335-350
    • /
    • 2004
  • Design takes concrete form from the things which are not yet exist to the molded reality. Creation of value which is accompanied by the rational value could be possible only through the searching examination of the basic concept. All designs are under circumstances because the results and the character of the problems are different under the given conditions and circumstances which are the characteristic of the design. The aim of this study is searching for the differential design conce- pt which is the most appropriate and reasonable in the basic design process in which the phase of the analysis, synthesis and evaluation of the problem. First of all the pursuit value of the times and the change of the view point of value of the product design. How the pursuit value of times were searched and analyzed. Analyze the successful product design realization of the typical trend of the modern design which are 3-2. function-focused design, 3-3. emotion-centered design, 3-4. image communicative design through the metaphor, 3-5. environmental affinity design. On the base of the case analysis how to apply the differential design concept which is coming as a trend in the future society which are sustainable developing society was examined closely. The outcome through the analysis of the success cases are as follows, \circled1 the value of the spirit of the times should be emphasized as the design image, \circled2 environmental appropriateness should be taken into consideration as the first primary factor, \circled3 the realization of value of the fulfillment of differential consumer's needs, \circled4 lead to prolong the life cycle of the product, \circled5 promote the sustaining growth of enterprise, \circled6 user-centered product value should be the first consideration. \circled7 It is necessary to overcome the cultural andinguistic barriers and to reflect the metaphor which people remember well. \circled8 The application of human's true character should be decided beforehand. It is the commonness of values of times and customs. \circled9 The differentiated design concept which meets our mental satisfaction, not material one, will be required. In addition to this the creative and differentiated design concepts which are accompanied by the good design factor under the base of product could achieve the emotional consensus from the consumers. That is, the value of all designs should be estimated by the base of the humanism ' The human beings are the barometer of all things".ngs".uot;.

  • PDF

Electrical Properties in $Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ Structure and the Role of $SrTiO_3$ Film as a Buffer Layer ($Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ 구조의 전기적 특성 분석 및 $SrTiO_3$박막의 완충층 역할에 관한 연구)

  • 김형찬;신동석;최인훈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.6
    • /
    • pp.436-441
    • /
    • 1998
  • $Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ structure was prepared by rf-magnetron sputtering method for use in nondestructive read out ferroelectric RAM(NDRO-FEAM). PBx(Zr_{0.52}Ti_{0.48})O_3}$(PZT) and $SrTiO_3$(STO) films were deposited respectively at the temperatures of $300^{\circ}C and 500^{\circ}C$on p-Si(100) substrate. The role of the STO film as a buffer layer between the PZT film and the Si substrate was studied using X-ray diffraction (XRD), Auger electron spectroscopy (ASE), and scanning electron microscope(SEM). Structural analysis on the interfaces was carried out using a cross sectional transmission electron microscope(TEM). For PZT/Si structure, mostly Pb deficient pyrochlore phase was formed due to the serious diffusion of Pb into the Si substrate. On the other hand, for STO/PZT/STO/Si structure, the PZT film had perovskite phase and larger grain size with a little Pb interdiffusion. the interfaces of the PZT and the STO film, of the STO film and the interface layer and $SiO_2$, and of the $SiO_2$ and the Si substate had a good flatness. Across sectional TEM image showed the existence of an amorphous layer and $SiO_2$ with 7nm thickness between the STO film and the Si substrate. The electrical properties of MIFIS structure was characterized by C-V and I-V measurements. By 1MHz C-V characteristics Pt/STO(25nm)/PZT(160nm)/STO(25nm)/Si structure, memory window was about 1.2 V for and applied voltage of 5 V. Memory window increased by increasing the applied voltage and maximum voltage of memory window was 2 V for V applied. Memory window decreased by decreasing PZT film thickness to 110nm. Typical leakage current was abour $10{-8}$ A/cm for an applied voltage of 5 V.

  • PDF

Phase Segmentation of PVA Fiber-Reinforced Cementitious Composites Using U-net Deep Learning Approach (U-net 딥러닝 기법을 활용한 PVA 섬유 보강 시멘트 복합체의 섬유 분리)

  • Jeewoo Suh;Tong-Seok Han
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.5
    • /
    • pp.323-330
    • /
    • 2023
  • The development of an analysis model that reflects the microstructure characteristics of polyvinyl alcohol (PVA) fiber-reinforced cementitious composites, which have a highly complex microstructure, enables synergy between efficient material design and real experiments. PVA fiber orientations are an important factor that influences the mechanical behavior of PVA fiber-reinforced cementitious composites. Owing to the difficulty in distinguishing the gray level value obtained from micro-CT images of PVA fibers from adjacent phases, fiber segmentation is time-consuming work. In this study, a micro-CT test with a voxel size of 0.65 ㎛3 was performed to investigate the three-dimensional distribution of fibers. To segment the fibers and generate training data, histogram, morphology, and gradient-based phase-segmentation methods were used. A U-net model was proposed to segment fibers from micro-CT images of PVA fiber-reinforced cementitious composites. Data augmentation was applied to increase the accuracy of the training, using a total of 1024 images as training data. The performance of the model was evaluated using accuracy, precision, recall, and F1 score. The trained model achieved a high fiber segmentation performance and efficiency, and the approach can be applied to other specimens as well.

STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE (Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구)

  • Kim, Jae-Tae;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The purpose of this study were to evaluate the efficacy of the newly developed Digital Imaging Fiber-Optic Trans-illumination (DIFOTI) system in detecting carious lesions in vivo as gold standard with confocal laser scanning microscopy and compared the efficacy of traditional radiography and DIFOTI system in vito as gold standard with confocal laser scanning microscopy, too. For the in vivo study, the subject pool consisted of 23 grammar school age patients just prior to entering the mixed dentition phase Each patient was given a DIFOTI examination of the anterior and posterior teeth. During $6{\sim}8$ months, the naturally expire primary teeth were collected and the efficacy of DIFOTI system was compared with confocal laser scanning microscopy. For in vitro study, 40 primary teeth were collected and decalcified by Carbopol decalcification solution for 1, 2, 4 and 8 days. Every experiment period, all teeth were DIFOTI examined and sectioned to take an image of confocal laser scanning microscopy Sensitivity and specificity were calculated from the result of DIFOTI examine and confocal laser scanning microscopy analysis. The results are as follows : 1. From the in vivo study, the sensitivity of DIFOTI examine was 0. 61 and specificity was 0.63. 2. From the in vivo study, the sensitivity of DIFOTI examine was 0.71 and specificity was 0.75.

  • PDF

Characterization of Ga-doped ZnO thin films prepared by RF magnetron sputtering method (RF 마그네트론 스퍼터링법으로 합성된 Ga-doped ZnO 박막의 특성평가)

  • Yun, Young-Hoon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.2
    • /
    • pp.73-77
    • /
    • 2021
  • Ga-doped ZnO thin films by RF magnetron sputtering process were synthesized according to the deposition conditions of O2 and Ar atmosphere gases, and rapid heat treatment (RTA) was performed at 600℃ in an N2 atmosphere. The thickness of the deposited ZnO : Ga thin film was measured, the crystal phase was investigated by XRD pattern analysis, and the microstructure of the thin film was observed by FE-SEM and AFM images. The intensity of the (002) plane of the X-ray diffraction pattern showed a significant difference depending on the deposition conditions of the thin films formed by O2 and Ar atmosphere gas types. In the case of a single thin f ilm doped with Ga under O2 conditions, a strong diffraction peak was observed. Under O2 and Ar conditions, in the case of a multilayer thin film with Ga doping, only a peak on the (002) plane with a somewhat weak intensity was shown. In the FE-SEM image, it was observed that the grain size of the surface of the thin film slightly increased as the thickness increased. In the case of a multilayer thin film with Ga doping under O2 and Ar atmosphere conditions, the specific resistance was 6.4 × 10-4 Ω·cm. In the case of a single thin film with Ga doping under O2 atmosphere conditions, the resistance of the thin film decreased. The resistance decreased as the thickness of the Ga-doped ZnO thin film increased to 2 ㎛, showing relatively a low specific resistance of 1.0 × 10-3 Ω·cm.