• Title/Summary/Keyword: Phase extraction method

Search Result 759, Processing Time 0.037 seconds

Development of Analysis Method of Caffeine and Content Survey in Commercial Foods by HPLC (HPLC를 이용한 카페인의 분석법 개발 및 시판 식품중 함유량 조사)

  • Kim, Hee-Yun;Lee, Young-Ja;Hong, Ki-Hyoung;Lee, Chul-Won;Kim, Kil-Saeng;Ha, Sang-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.1471-1476
    • /
    • 1999
  • A simple and practical method for determination of caffeine in foods was developed. The analysis of caffeine was performed by reverse phase high performance liquid chromatography using a ${\mu}-Bondapak\;C_{18}$ column at isocratic condition with methanol-acetic acid-water(20 : 1 : 79) on UV detector at 280 nm. The clean-up and extraction of caffeine in samples were based on a simple pretreatment using a Sep-Pak $C_{18}$ cartridge. Recovery rates obtained with this method for cider, candy, cookie, milk, ice cream and persimmon leaf tea were 99.23%, 99.50%, 99.17%, 99.37%, 98.93% and 99.10% respectively. And the detection limit of caffeine was $0.1\;{\mu}g/mL$. With this method, the range of caffeine contents extracted from coffee, green tea, black tea, Oolong tea(tea bag), soft drinks, ice cream, milk and commercial confectionery were $3.38{\sim}37.50\;mg/g,\;16.30{\sim}26.10\;mg/g,\;10.80{\sim}16.65\;mg/g,\;11.25\;mg/g,\;0.06{\sim}0.11\;mg/g,\;0.04{\sim}0.44\;mg/g,\;0.04{\sim}0.39\;mg/g\;and\;0.10{\sim}1.80\;mg/g$, respectively. But caffeine was not detected in the other tea such as Acanthopanax sessiliflorum tea, Angelica gigas tea, Angelica tea, Arrow root tea, Duchu'ng tea, Dunggulle tea, Ganoerma lucidum tea, Ginger tea powder, Persimmon leaf tea, Ssanghwa tea and Cocoa mix powder.

  • PDF

Phytochemical contents of agricultural products cultivated by region (재배지역에 따른 농산물의 phytochemical 함량)

  • Na, Hwan Sik;Kim, Jin Young;Yun, Seol Hee;Park, Hak Jae;Choi, Gyeong Cheol;Yang, Soo In;Lee, Ji Heon;Cho, Jeong Young
    • Food Science and Preservation
    • /
    • v.20 no.4
    • /
    • pp.451-458
    • /
    • 2013
  • The purpose of this research is to distinguish the quantitative determination of phytochemicals in various agricultural products and to optimize an HPLC method for the determination of lycopene, lutein, ${\alpha}$-carotene, ${\beta}$-carotene, and cryptoxanthin. Among the different conditions studied, the most suitable ones for our samples were the extraction with hexane/acetone/ethanol (50:25:25, v/v/v), dissolution of the dry extract in tetrahydrofuran/acetonitrile/methanol (15:30:55, v/v/v), injection on a $C_{18}$ column with methanol/acetonitrile (90:10, v/v) + triethylamine $9{\mu}M$ as mobile phase, and ${\lambda}_{detection}$=475 nm. The mean percent recovery for the HPLC method were $120.7{\pm}4.1%$ (lycopene), $89.2{\pm}3.5%$ (lutein), $91.2{\pm}2.9%$ (${\alpha}$-carotene), $99.1{\pm}4.4%$ (${\beta}$-carotene), and $100.0{\pm}5.3%$ (cryptoxanthin). The contents of lutein in the agricultural products were spinach, kiwi, tomato, blueberry, melon, respectively. However, the lycopene contents were the highest in the Black tomato ($56.66{\pm}7.48mg/kg$) and Jangseong tomato ($50.28{\pm}5.42mg/kg$). The concentration of ${\beta}$-carotene in all of the agricultural products ranged from 0.07 mg/kg to 65.03 mg/kg. The quercetin content of the agricultural products increased in the order of blueberry (986.57~1,054.06 mg/100 g), kiwi (44.96~55.09 mg/100 g), hallabong (31.92~35.60 mg/100 g), and tomato (26.38~34.94 mg/100 g). The highest kaempferol content was found in the blueberry (47.79~76.15 mg/100 g) with results in all of the tested samples varying between 6.54~48.11 mg/100 g. The total polyphenol contents of the various agricultural products increased in the blueberry (213.60~229.96 mg/100 g), spinach (112.50~141.67 mg/100 g) and kiwi (46.49~70.44 mg/100 g). The total flavonoid content was the highest in both blueberry and spinach. Vitamin C content was detected in kiwi > hallabong > tomato > blueberry, respectively. The total anthocyanin contents (TAC) was detected in the Damyang blueberry and the imported blueberry.

Improvement of an Simultaneous Determination for Clenbuterol and Ractopamine in Livestock Products using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 clenbuterol과 ractopamine의 동시 분석법 개선)

  • Cho, Yoon-Jae;Chae, Young-Sik;Kim, Jae-Young;Kim, Hyung-Soo;Kang, Ilhyun;Do, Jung-Ah;Oh, Jae-Ho;Kwon, Kisung;Chang, Moon-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.25-33
    • /
    • 2013
  • Clenbuterol and ractopamine, which are ${\beta}$-agonists, have been misused as a growth promoting agent in meat producing animals. Clenbuterol was banned for veterinary drug in Korea because of its problems regarding safety. Due to their adverse effects, such as cardiovascular and central nervous diseases on human health proper control and monitoring should be conducted. The existing analytical method of clenbuterol and ractopamine in the Food code was improved through our present study. The bovine muscle samples were subjected to enzymatic hydrolysis, extracted with ethyl acetate and defatted by hexane-methanol partitioning. A molecular imprinted polymer (MIP) solid phase extraction cartridge was used for clean-up and LC-MS/MS was operated in positive multiple reaction monitoring (MRM). Clenbuterol-$d_9$ and ractopamine-$d_3$ were used as an internal standard. The renewed method was validated according to the CODEX guideline. The limits of quantitation for clenbuterol and ractopamine were 0.2 and 0.5 ${\mu}g/kg$, respectively. The mean recoveries ranged in 104.2-113.5% for clenbuterol and in 107.6-118.1% for ractopamine. The improved method was able to save both time and expenses.

A study of relationship between stomach cancer and selenoproteins in Korean human blood serum (한국인 혈청에서의 셀레노 단백질과 위암과의 상관관계 연구)

  • Park, Myungsun;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.417-424
    • /
    • 2015
  • In this study, the relationship between selenoprotein concentrations in blood and stomach cancer have been searched for Korean. The concentration of each selenoprotein in blood serum was analyzed and the correlation between the concentration and stomach cancer was studied to find a potential for using Selenium as a biomarker. In concentration determination, a simple calibration curve method was used with the monitoring of m/z 78 without the use of solid phase extraction. This is a lot more simple than the method using SPE with post column isotope dilution. The result obtained from the analysis of CRM BCR-637, 72.20±3.35 ng·g−1, showed similar value of reference value (81±7 ng·g−1). The total concentration of Se for the controlled group, cardiovascular patients group, was 105.70±21.20 ng·g−1. This value was the same as normal healthy person reported earlier. Each selenoprotein concentration of GPx, SelP and SeAlb was 26.12±7.84, 65.15±14.50, 14.43±6.99 ng·g−1, respectively. The distribution of each selenoprotein was 24.7%, 61.6%, and 13.7%, which was similar to the normal person. The result of stomach cancer patients, the total concentration of Se was 76.11±28.12 ng·g−1 and each concentration of GPx, SelP and SeAlb was 15.41±9.01, 50.83±17.91, and 9.87±5.21 ng·g−1, respectively. The total and each selenoprotein concentration level showed significant decrease for the stomach cancer patients. The level of decrease was 41.0% for GPx, 22.0% for SelP, and 31.6% for SeAlb. However, the distribution of each selenoprotein was not much different. Either total Selenium or each selenoprotein could be used as a possible index for the diagnosis of cancer. However, in age group study, it is shown that young age group (30's-40's) did not show much difference.

Method Development for the Sample Preparation and Quantitative Analysis of Synthetic Colors in Foods (식품 중 식용타르색소의 시료별 전처리방법 확립 및 함량 분석)

  • Park, Sung-Kwan;Lee, Tal-Su;Park, Seung-Kook
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.893-899
    • /
    • 2004
  • Method for sample preparation and quantitative analysis of 19 permitted and non-permitted synthetic colors in foods was developed based on reversed-phase ion-pairing high performance liquid chromatography. For color extraction of samples, deionized water was added, and pH was appropriately adjusted with 1% ammonia water. Any undissolved matters were extracted with 50% ethanol or 70% methanol. Lipid in snacks was first removed using n-hexane with centrifugation, water was added to extract colors, followed by clean-up and concentration using Sep-Pak $C_{18}$ cartridge. Recovery efficiencies at known concentrations of 19 standard food colors spiked into foods were in 90.3-97.9% range far soft drink, 79.2-101.9% for candy, 84.1-103.4% for jelly, 86.4-100.8% for chewing gum, 83.5-103.4% for ice cream, and 78.5-95.6% for snack.

Perfluoropolymer Membranes of Tetrafluoroethylene and 2,2,4Trifluofo- 5Trifluorometoxy- 1,3Dioxole.

  • Arcella, V.;Colaianna, P.;Brinati, G.;Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.39-42
    • /
    • 1999
  • Perfluoropolymers represent the ultimate resistance to hostile chemical environments and high service temperature, attributed to the presence of fluorine in the polymer backbone, i.e. to the high bond energy of C-F and C-C bonds of fluorocarbons. Copolymers of Tetrafluoroethylene (TEE) and 2, 2, 4Trifluoro-5Trifluorometoxy- 1, 3Dioxole (TTD), commercially known as HYFLON AD, are amorphous perfluoropolymers with glass transition temperature (Tg)higher than room temperature, showing a thermal decomposition temperature exceeding 40$0^{\circ}C$. These polymer systems are highly soluble in fluorinated solvents, with low solution viscosities. This property allows the preparation of self-supported and composite membranes with desired membrane thickness. Symmetric and asymmetric perfluoropolymer membranes, made with HYFLON AD, have been prepared and evaluated. Porous and not porous symmetric membranes have been obtained by solvent evaporation with various processing conditions. Asymmetric membranes have been prepared by th wet phase inversion method. Measure of contact angle to distilled water have been carried out. Figure 1 compares experimental results with those of other commercial membranes. Contact angles of about 120$^{\circ}$for our amorphous perfluoropolymer membranes demonstrate that they posses a high hydrophobic character. Measure of contact angles to hexandecane have been also carried out to evaluate the organophobic character. Rsults are reported in Figure 2. The observed strong organophobicity leads to excellent fouling resistance and inertness. Porous membranes with pore size between 30 and 80 nanometers have shown no permeation to water at pressures as high as 10 bars. However high permeation to gases, such as O2, N2 and CO2, and no selectivities were observed. Considering the porous structure of the membrane, this behavior was expected. In consideration of the above properties, possible useful uses in th field of gas- liquid separations are envisaged for these membranes. A particularly promising application is in the field of membrane contactors, equipments in which membranes are used to improve mass transfer coefficients in respect to traditional extraction and absorption processes. Gas permeation properties have been evaluated for asymmetric membranes and composite symmetric ones. Experimental permselectivity values, obtained at different pressure differences, to various single gases are reported in Tab. 1, 2 and 3. Experimental data have been compared with literature data obtained with membranes made with different amorphous perfluoropolymer systems, such as copolymers of Perfluoro2, 2dimethyl dioxole (PDD) and Tetrafluorethylene, commercialized by the Du Pont Company with the trade name of Teflon AF. An interesting linear relationship between permeability and the glass transition temperature of the polymer constituting the membrane has been observed. Results are descussed in terms of polymer chain structure, which affects the presence of voids at molecular scale and their size distribution. Molecular Dyanmics studies are in progress in order to support the understanding of these results. A modified Theodoru- Suter method provided by the Amorphous Cell module of InsightII/Discover was used to determine the chain packing. A completely amorphous polymer box of about 3.5 nm was considered. Last but not least the use of amorphous perfluoropolymer membranes appears to be ideal when separation processes have to be performed in hostile environments, i.e. high temperatures and aggressive non-aqueous media, such as chemicals and solvents. In these cases Hyflon AD membranes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

Determination and Survey of Fluoroquinolones Residue in Chicken Muscle by HPLC with Fluorescence Detector (액체크로마토그래피-형광검출기를 이용한 닭고기 중 플루오로퀴놀론계 항균물질 정량분석 및 잔류조사)

  • 박은정;임지흔;이성모
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.1
    • /
    • pp.12-18
    • /
    • 2004
  • Ofloxacin, norfloxacin, ciprofloxacin, and enrofloxacin in chicken muscle were seperated by liquid extraction and determined with high performance liquid chromatography (HPLC) with fluorescence detector. Analysis was carried out using following conditions; Cl8 column (250${\times}$4.6 mm i.d. 5 ${\mu}{\textrm}{m}$ particle size), mobile phase composed of D.W. (containing 0.4% triethylamine and phospholic acid): methanol : acetonitrile (800:100:100, v/v/v), isocratic pump at a flow rate of 1.0 $m\ell$/min and 50 ${mu}ell$ of injection volume, fluorescence detector with EX278 nm/EM.456 nm. The calibration curves of four fluoroquinolones showed linearity (${\gamma}$$^2$$\geq$0.999) at concenration range of 0.025-0.6 $\mu\textrm{g}$/ml. The recoveries in fortified chicken muscle represented more than 80% with low coefficient of variation (〈10%) for concentration range of four fluoroquinolones. The detection limits for ofloxacin, norfloxacin, ciprofloxacin, and enrofloxacin were 23.5, 3.4, 3.0 and 2.5 ng/g in chicken muscle, respectively. We also monitored fluoroquinolones residue in muscle of chickens (broiler 1:227, Korean native chicken 219, laying chicken 77) using EEC-4-plate screening and HPLC conformation methods. Ten(broiler 5, Korean native chicken 5) out of the fifteen samples which were positively detected by EEC-plate screening method from 1,523 chicken meat were confirmed with ciprofloxacin and enrofloxacin by HPLC. The ranges of residual concentration were 0-0.12 ppm for ciprofloxacin and 0.01-6.79 ppm for enrofloxacin. In conclusion, our method could be applied effectively to determine four fluoroquinolones residues in chicken meat, and further survey for fluoroquinolones residue in chicken meat are needed for more effective control of fluoroquinolones used in livestock.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.

Development of a Simultaneous Analytical Method for Determination of Insecticide Broflanilide and Its Metabolite Residues in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살충제 Broflanilide 및 대사물질 동시시험법 개발)

  • Park, Ji-Su;Do, Jung-Ah;Lee, Han Sol;Park, Shin-min;Cho, Sung Min;Kim, Ji-Young;Shin, Hye-Sun;Jang, Dong Eun;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.124-134
    • /
    • 2019
  • An analytical method was developed for the determination of broflanilide and its metabolites in agricultural products. Sample preparation was conducted using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method and LC-MS/MS (liquid chromatograph-tandem mass spectrometer). The analytes were extracted with acetonitrile and cleaned up using d-SPE (dispersive solid phase extraction) sorbents such as anhydrous magnesium sulfate, primary secondary amine (PSA) and octadecyl ($C_{18}$). The limit of detection (LOD) and quantification (LOQ) were 0.004 and 0.01 mg/kg, respectively. The recovery results for broflanilide, DM-8007 and S(PFP-OH)-8007 ranged between 90.7 to 113.7%, 88.2 to 109.7% and 79.8 to 97.8% at different concentration levels (LOQ, 10LOQ, 50LOQ) with relative standard deviation (RSD) less than 8.8%. The inter-laboratory study recovery results for broflanilide and DM-8007 and S (PFP-OH)-8007 ranged between 86.3 to 109.1%, 87.8 to 109.7% and 78.8 to 102.1%, and RSD values were also below 21%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food and Drug Safety Evaluation guidelines (2016). Therefore, the proposed analytical method was accurate, effective and sensitive for broflanilide determination in agricultural commodities.