• Title/Summary/Keyword: Phase consistency

Search Result 157, Processing Time 0.028 seconds

Update Protocol for Distributed Spatial Objects with Spatial Relationships based on OGIS OLE DB (OGIS OLE DB 기반의 공간관련성을 가진 분산 공간객체의 변경 프로토콜)

  • Kim, Dong-Hyun;Moon, Sang-Ho;Hong, Bong-Hee
    • The KIPS Transactions:PartD
    • /
    • v.11D no.2
    • /
    • pp.259-268
    • /
    • 2004
  • For supporting Interoperability among heterogeneous data sources in different geographic information systems, it is required to use open API like OGIS OLE DB Proposed in OGC. The OLE/COM Implementation Specification of OGIS only provides interfaces to discover and access spatial data, but does not support interfaces for updating distributed spatial data. To solve this problem, we propose and add interfaces for updating spatial objects distributed over heterogeneous data sources and examining the consistency of spatial relationships between updated objects. We also devise a 2-phase commit protocol based on spatial relationships in order to guarantee the consistency of updated objects. To justify the update scheme using the proposed Interfaces and 2-phase commit prototype we design and implement a prototype system for updating distributed spatial objects.

Changes in Physical Properties of Dredged Soils by Drying (건조에 의한 준설 매립 지반에 물리적 특성변화)

  • Yonn Yong-Han;Kim Won-Tae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.2 s.115
    • /
    • pp.36-43
    • /
    • 2006
  • This study was carried out to determine the ways in which drying improves and develops dredged soils which exist widely in the lowlands of Korea. Before drying there were large variations in the fundamental physico-chemical properties of dredged soils collected from different places. In the sample soils, saturated hydraulic conductivity decreased gradually with an increase in bulk density with the exception that in air-dried soils a reverse trend was observed. Also in the sample soils, the sedimentation volume and the consistency limits decreased gradually with the decrease in soil water content after the air-drying treatment. The porosity of the sample soils decreased from $0.67{\sim}0.87m^3/m^3\;to\;0.58{\sim}0.66m^3/m^3$ and the liquid-phase range decreased from $0.41{\sim}0.83m^3/m^3\;to\;0.29{\sim}0.71m^3/m^3$. The solid-phase range of sample soils increased $0.13{\sim}0.33m^3/m^3\;to\;0.24{\sim}0.37m^3/m^3$ same as above with air-drying treatment. In conclusion the air-drying treatment caused an irreversible effect on some physical properties. Accordingly, these facts indicate that the effects of air-drying treatment on these properties are considered to be resulted from irreversible changes in the structural status of the sample soils.

A Behavior Conformance Checker for Component Interfaces using UML State Machine Diagram (UML 상태기계 다이어그램을 이용한 컴포넌트 인터페이스의 행위 호환성 검증 도구)

  • Kim, Ho-Jun;Lee, Woo-Jin
    • The KIPS Transactions:PartD
    • /
    • v.16D no.1
    • /
    • pp.65-72
    • /
    • 2009
  • Component based development has increasingly become important in the software industry. However, in the current component based development approach with UML, the absence of behavioral description of components brings about a cost problem which causes semantic errors on the testing phase. Accordingly we cannot grasp the usage pattern of component by its provided interfaces which refer to an abstraction of software component. And we cannot guarantee the behavioral conformance of the provided and required interfaces of components. In order to solve these problems, we describe the behaviors of component interfaces by state machine diagram and guarantee their behavior conformance at the modeling phase. We also propose a method to guarantee the behavior conformance of component interfaces with concept of observation equivalence and invocation consistency. And we provide an analyzing tool which checks interface behavior conformance.

A study on the Development of BIM-based Quality Pre-checking System in Architecture Design Phase

  • Shin, Jihye;Choi, Jungsik;Kim, Inhan
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.284-288
    • /
    • 2015
  • Recently, the mandate on utilizing BIM implemented by public institutions of many countries has great impact on the significantly increasing practices of BIM. The improvement of work efficiency and productivity, which is occurred by BIM adoption, depends on the consistency and accuracy of data. To maximize the benefit of BIM, the interests in BIM data quality have been enlarging all over the world. The BIM data quality pre-check, which is conducted by designer in the design phase, offers opportunities for quality improvement by continuously assessing BIM data. However, BIM quality pre-check is being conducted under arbitrary interpretation of users because of the absence of specific review factors and assessment methods for checking BIM quality. The purpose of this study is to establish an automated BIM quality pre-checking system to improve BIM design quality effectively and efficiently. It could be expected to meet the owner's requirements and to minimize the cost and time occurred additionally from revising and reproducing data by constructing consistency and accuracy of it.

  • PDF

Switching Functions Model of a Three-phase Voltage Source Converter (VSC)

  • Fazeli, Seyed Mahdi;Ping, Hew Wooi;Abd Rahim, Nasrudin Bin;Ooi, Boon Teck
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.422-431
    • /
    • 2017
  • The equivalent circuit of a three-leg, four-wire voltage source converter (VSC) is derived using switching functions. Simulations and experiments are conducted (i) to investigate the effects of the zero sequence on VSCs when a three-phase imbalance exists and (ii) to use the consistency of simulations and laboratory experiments to validate the equivalent circuit. The impact of a three-phase imbalance on the VSC has yet to be fully investigated because of the lack of an equivalent circuit to show rigorously how the zero sequence currents flow through the VSC.

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement Equipment (전압변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 평가기술)

  • 정재갑;박영태;권성원
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.9
    • /
    • pp.470-474
    • /
    • 2004
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of burden of VT used. A method of evaluation for linearity of ratio error and phase angle error in VT measurement equipment have been developed using the standard resistance burdens, with negligible AC-DC resistance difference less than $10^-6$. These burden consists of five standard resistors, with nominal resistance of 100 $\Omega$, 1 k$\Omega$, 10 k$\Omega$, 100 k$\Omega$, and 1 M$\Omega$. The developed method has been applied in VT measurement equipment of industry and the validity of the developed method has been verified by showing the consistency of the result of linearity obtained using VT with wide ratio error.

A STUDY OF GEL STRUCTURE IN THE NONIONIC SURFACTANT / CETOSTEARYL ALCOHO L/ WATER TERNARY SYSTEMS BY DIFFERENTIAL SCANNING CALORIMETER

  • Yoon, Moung-Seok;Chung, Youn-Bok;Kun Han
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.26 no.1
    • /
    • pp.213-232
    • /
    • 2000
  • Cetostearyl alcohol has been incorporated into cosmetic or pharmaceutial emulsions to give them an appropriate consistency and a long term stability. It is well known that cetostearyl alcohol forms a gel phase with a nonionic surfactant in an aqueous system, and the properties of the gel phase depend on several factors such as the ratio of fatty alcohols. The aim of the present Paper is to investigate the effect of the structural difference of the lipophilic part of surfactants on the stability of the gel phase in the nonionic surfactant / cetostearyl alcohol / water ternary systems using differential scanning calorimeter. It is concluded that the gel phase formed by the surfactant having the bended alkyl chain is more unstable than that formed by the case of the straight alkyl chain, and we discussed the reason why the former is more unstable after long term storage by means of the measurements of the ${\Delta}$H.

  • PDF

An Efficient Altruistic Looking Protocol for the Mobile Transaction Management System (이동 데이터베이스 시스템을 위한 효율적인 이타적 잠금기법)

  • 권혁신;김세윤;김응모
    • Journal of Information Technology Applications and Management
    • /
    • v.11 no.1
    • /
    • pp.53-67
    • /
    • 2004
  • We propose an advanced transaction scheduling protocol to improve the concurrency and to guarantee the mobility for the mobile database management systems. Mobility, portability, and wireless link In mobile computing environment can cause certain drawbacks, and thus it is more difficult to solve the concurrency control problems. However, a locking scheme should be used to guarantee the data consistency and to prevent the data conflicts. It is well known that data consistency is guaranteed by standard transaction scheduling schemes like two-phase locking (2PL). It has two of operation, lock and unlock. But 2PL does not give solution for mobile system. Altruistic Locking (AL) and classifying transactions, we adapt, can give solution for the previous problems. AL, as an advanced protocol, has attempted to reduce delay effects associated with lock release moment by the use of donation. In this paper, we extend those approaches and classify the transactions to reduce delay effects of short-lived transaction caused by long-lived transaction. In addition, we show efficient solution for the case of disconnection occurrence. Our protocol, namely, Mobile Altruistic Locking (MAL) is shown to be efficiently used in order to reduce delay effects and to guarantee database consistency in a state of the slippery connection in mobile database systems.

  • PDF

A Modified Barium Swallowing Study of Stroke Patients with Different Consistencies (노졸중자의 연하 과정에 대한 연하조영 촬영분선 연구)

  • Noh, Dong-Woo;Paik, Eun-A;Kang, Soo-Kyoon
    • Speech Sciences
    • /
    • v.10 no.4
    • /
    • pp.229-239
    • /
    • 2003
  • The purposes of this study are; to investigate the swallowing mechanism of stroke patients with different consistencies through the modified barium swallowing(MBS); and to establish preliminary data on the differences in swallowing durations. 4 different kinds of consistency-water, nectar, pudding, and crackers-were given to 6 stroke patients and their swallowing durations recorded through the fluoroscopy were measured in 1/100 second units. The results show that first swallowing time(FST), the oral preparatory duration(OPD), and the pharyngeal response duration(PRD) were delayed in swallowing thicker consistencies. However, water exhibited delayed oral and pharyngeal phase relative to its consistency and 50% of subjects showed oral loss of water. The relationship between consistencies and swallowing durations and the clinical issues on the stroke population were discussed.

  • PDF

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement System Using Capacitor Burden (전기용량 부담을 이용한 전압변성기 비교 측정 시스템의 비오차 및 위상각 오차의 직선성 평가기술)

  • Jung Jae Kap;Kim Han Jun;Kwon Sung Won;Kim Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.274-278
    • /
    • 2005
  • Voltage transformer(VT) comparison measurement system is usually used for measurements of ratio error and phase angle error of VT made in industry. Both ratio error and phase angle error in VT are critically influenced by values of burden of VT used. External burden effects on both ratio error and phase angle error in VT are theoretically calculated. From the theoretical calculation, a method of evaluation for linearity of ratio error and phase angle error in VT measurement system have been developed using the standard capacitive burdens, with negligible dissipation factor less than 10$^{-4}$. These burden consists of five standard capacitors, with nominal capacitance of 1.1 $\mu$F, 1 $\mu$F, 0.1 $\mu$F, 0.01 $\mu$F, 0.001 $\mu$F. The developed method has been applied in VT measurement system of industry, showing in good consistency and linearity within 0.001 $\%$ between theoretical and measured values.