• 제목/요약/키워드: Phase compensation

검색결과 990건 처리시간 0.027초

The Phase Estimation Algorithm of Arrival Phase Differences in Space-Time Coded Communication

  • Jung, Ji-Won;Huang, Xinping;Caron, Mario;Kim, Min-Hyuk;Kim, Ki-Man;Yun, Young
    • ETRI Journal
    • /
    • 제28권5호
    • /
    • pp.680-683
    • /
    • 2006
  • One objective in developing the next generation of wireless communication systems is to increase data rates and reliability. A promising way to achieve this is to combine multiple-input and multiple-output signal processing with a space-time coding scheme, which offers higher coding and diversity gains and improves the spectrum efficiency and reliability of a wireless communication system. It is noted, however, that time delay differences and phase differences among different channels increase symbol interference and degrade system performance. In this letter, we investigate phase differences and their effects on multiple-input and multiple-output systems, and propose a compensation algorithm for the Rayleigh fading model to minimize their effects.

  • PDF

Frequency Responses of Ambulatory ECG Systems and Their Correction by a Compensation Circuit

  • Iwao, K.;Yokoi, A.;Suzuki, S.;Goto, T.;Doniwa, K.;Okajima, M.
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 1990
  • Frequency responses of ambulatory electrocardiogram systems were measured. Phase shift was assessed by our improved Wagner's method. The characteristics of the systems were found much worse than that of ordinary ECG equipment both in gain and phase responses. The decay of -3dB in amplitude observed in 0.2Hz and the lead of 45 dog in phase was observed in 0.6Hz. In order to investigate which of these 2 responses play major role in generating false S -T deviation, mathe- matical filters were Composed in a computer and actual ECGs were fed. The false S-T deviation were found to be caused mostly by enormous lead in phase, and then, the compensation circuit to diminish the lead in phase was inserted in the commercial systemes. The compensated systems showed no false deviation in S-T segment.

  • PDF

Series Active Power Filters to Compensate Harmonics and Reactive Power with the Direct Compensating Voltage Extraction Method in Three-Phase Four-Wire Systems

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.691-699
    • /
    • 2009
  • This paper presents the analysis of series active power filter for reactive power compensation, load balancing, harmonic elimination, and neutral current eradication in three-phase four-wire power systems. Generally, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its 3rd harmonics are termed as triple and zero sequence components that do not cancel each other in the system neutral. Consequently, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control algorithm for a series hybrid active system, whereas the control approach it adopts directly influence its compensation characteristics. Hence, the advantage of this control algorithm is the direct extraction of compensation voltage reference without phase transformations and multiplying harmonic current value by gain and the required rating of the series active filter is much smaller than that of a conventional shunt active power filter. In order to show the effectiveness of the proposed control algorithm, experiments have been carried out.

단상 계통 연계형 인버터의 빠른 동특성을 갖는 계통 전압 센싱 DC 오프셋 보상 알고리즘 (DC offset Compensation Algorithm with Fast Response to the Grid Voltage in Single-phase Grid-connected Inverter)

  • 한동엽;박진혁;이교범
    • 전기학회논문지
    • /
    • 제64권7호
    • /
    • pp.1005-1011
    • /
    • 2015
  • This paper proposes the DC offset compensation algorithm with fast response to the sensed grid voltage in the single-phase grid connected inverter. If the sensor of the grid voltage has problems, the DC offset of the grid voltage can be generated. This error must be resolved because the DC offset can generate the estimated grid frequency error of the phase-locked loop (PLL). In conventional algorithm to compensate the DC offset, the DC offset is estimated by integrating the synchronous reference frame d-axis voltage during one period of the grid voltage. The conventional algorithm has a drawback that is a slow dynamic response because monitoring the one period of the grid voltage is required. the proposed algorithm has fast dynamic response because the DC offset is consecutively estimated by transforming the d-axis voltage to synchronous reference frame without monitoring one cycle time of the grid voltage. The proposed algorithm is verified from PSIM simulation and the experiment.

광섬유 분산 변동에 따른 왜곡된 WDM 채널의 보상 특성 (Compensation Characteristics or Distorted WDM Channel dependence on Variation of Fiber Dispersion)

  • Lee, Seong-Real
    • 한국통신학회논문지
    • /
    • 제29권7A호
    • /
    • pp.719-726
    • /
    • 2004
  • 광섬유의 분산이 균일하지 않다는 가정 하에 색 분산과 자기 위상 변조 (SPM : Self Phase Modulation) 현상에 의해 왜곡된 WDM 채널의 보상 특성을 수치적으로 살펴보았다. 본 연구에서 사용한 보상 기법은 전체 전송 링크 중간에 광 위상 공액기 (OPC: Optical Phase Conjugator)를 두어 보상하는 MSSI (Mid-Span Spectral Inversion)이다. OPC를 중심으로 두 광섬유 구간의 분산 계수 분포가 변동하면서 서로 일치하지 않은 경우에도 전송 채널의 입력 전력을 적절히 조절함으로써 MSSI를 통해 장거리 전송이 가능하다는 것을 알 수 있었다. 즉 장거리 WDM 시스템에 MSSI를 적용하게 되면 전송 선로 곳곳에 필요한 보상기(compensator) 등을 없앨 수 있고, 결과적으로 시스템 비용을 절감할 수 있을 것으로 기대된다.

PSS 튜닝을 위한 기본 연구 PART II : PSS 실계통 최적 정수 선정을 위한 튜닝기법 (A Basic Study for Tuning Power System Stabilizer PART-II : Tuning Methods for Selecting Optimal PSS Parameters in Real Power Systems)

  • 김태균;신정훈;윤용범;김동준;문영환;백영식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.350-358
    • /
    • 2000
  • Based on the results in the first-part paper, PSS tuning methods including the determination of PSS gain and compensation of phasor lagging are investigated in this second part. In the phase compensation, PSS should compensate phase lagging, resulted from power system-generator-excitation system loop, to provide damping torque in equal phase with the generator speed. Also, PSS gain should be determined to provide maximum damping torque as much as possible without the other modes unstable. In this paper, gain tuning method using the root-locus and the phase compensation of PSS at the one machine with infinite bus system are presented. The differences between PSS tuning at the tuning condition and at the least-stable condition are also discussed.

  • PDF

A Multiphase Compensation Method with Dynamic Element Matching Technique in Σ-Δ Fractional-N Frequency Synthesizers

  • Chen, Zuow-Zun;Lee, Tai-Cheng
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권3호
    • /
    • pp.179-192
    • /
    • 2008
  • A multiphase compensation method with mismatch linearization technique, is presented and demonstrated in a $\Sigma-\Delta$ fractional-N frequency synthesizer. An on-chip delay-locked loop (DLL) and a proposed delay line structure are constructed to provide multiphase compensation on $\Sigma-\Delta$ quantizetion noise. In the delay line structure, dynamic element matching (DEM) techniques are employed for mismatch linearization. The proposed $\Sigma-\Delta$ fractional-N frequency synthesizer is fabricated in a $0.18-{\mu}m$ CMOS technology with 2.14-GHz output frequency and 4-Hz resolution. The die size is 0.92 mm$\times$1.15 mm, and it consumes 27.2 mW. In-band phase noise of -82 dBc/Hz at 10 kHz offset and out-of-band phase noise of -103 dBc/Hz at 1 MHz offset are measured with a loop bandwidth of 200 kHz. The settling time is shorter than $25{\mu}s$.

위상 보상과 가중치 평균을 이용한 의료 초음파 신호의 주파수 특성 추출 방법 (Extraction Method of Ultrasound Spectral Information using Phase-Compensation and Weighted Averaging Techniques)

  • 김형석;이준환
    • 한국정보통신학회논문지
    • /
    • 제14권4호
    • /
    • pp.959-966
    • /
    • 2010
  • 정량적 초음파 분석(Quantitative Ultrasound Analysis)은 반향된 초음파 신호의 짧은 시간 간격의 주파수 성분을 추출하여 개별 초음파 지수의 값을 예측한다. 따라서 반향 신호의 정확한 주파수 특성 추출은 분석의 정확도와 정밀도 향상에 기본이 된다. 본 논문에서는 초음파 지수의 정량적인 예측 및 분석에 이용할 수 있는, 짧은 시간 간격의 반향 신호의 주파수 특성 추출 방법을 제안한다. 제안된 알고리듬은 인접한 반향 초음파 신호간의 위상 차이를 보상하고, 동일 반향 깊이를 가지는 작은 영역의 신호를 가중치 평균함으로써 보다 정확한 주파수 특성을 추출한다. 컴퓨터 모의 실험을 통한 수치 분석 결과, 제안된 알고리듬은 일반적인 주파수 추출 알고리듬보다 정확한 예측 결과를 보였으며, 예측 결과의 정밀도도 10% 이상 향상되었다.

A Novel Control Algorithm of a Three-phase Four-wire PV Inverter with Imbalance Load Compensation Function

  • Le, Dinh-Vuong;Kim, Chang-Soon;Go, Byeong-Soo;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1131-1137
    • /
    • 2018
  • In this paper, the authors suggest a new control algorithm for a three-phase four-wire photovoltaic (PV) inverter with imbalance load compensation function using conventional proportional-integral (PI) controllers. The maximum power of PV panel is calculated by the MPPT control loop. The reference varying signals of current controllers are transformed to two different rotating frames where they become constant signals. Then simple PI controllers are applied to achieve zero steady-state error of the controllers. The proposed control algorithm are modeled and simulated with imbalance load configuration to verify its performance. The simulation results show that the maximum PV power is transferred to the grid and the imbalance power is compensated successfully by the proposed control algorithm. The inverter has a fast response (~4 cycles) during the transient period. The proposed control algorithm can be effectively utilized to the three-phase four-wire inverter with imbalance load compensation function.

테이블 방법을 이용한 절대위치 검출기에 대한 개선된 위상 오차 보상 (An Improved Phase Error Compensation for an Absolute Position Detector using Table Method)

  • 안기호;김시현;양윤기;이창수
    • 제어로봇시스템학회논문지
    • /
    • 제16권10호
    • /
    • pp.975-981
    • /
    • 2010
  • Existing error compensation method of industrial electronic absolute displacement detector only depends on skilled engineers. This paper proposes a new table method in order to automatize error compensation. An waveform changes according to the parallel resistance for each pole were tabularized and four waveforms were superimposed to minimize total phase error. These process was verified using simulink. As a result of applying proposed method to the real sensor, peak to peak error was reduced from $3.428^{\circ}$ to $0.879^{\circ}$. In this case, compensation resistance is $4.7k\Omega$ in B pole and $20k\Omega$ in C pole. This compensation rate is comparable to skilled engineers, and it takes 0.8 second which is far shorter than 15 minutes when expert does.