• Title/Summary/Keyword: Phase analysis

Search Result 11,890, Processing Time 0.048 seconds

A Biomechanical Analysis of 540o Dwihuryeochagi of Taekwondo (태권도 540도 뒤후려차기 동작의 운동역학적 분석)

  • Kang, Dong-Kwon;Kang, Suh-Jung;Yu, Yeon-Joo
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.1
    • /
    • pp.19-24
    • /
    • 2013
  • The aim of the study was a quantitative analysis of elite athlete's $540^{\circ}$ Dwihuryeochagi and effects of ground movements to the jumping height and kicking velocity. Eleven elite players(Taekwondo demonstration team) participated in this study. In order to get the kinetic and kinematic variables, ten Vicon cameras and a force plate were used. Foot segment velocity(FSV), vertical ground reaction force(GRF), impulse, ground time(GT) in phase 1, trunk angular velocity(TAV), vertical center of gravity(COG), flight time(FT) in phase 2 and kicking leg segment velocity(KSV) in phase 3 were measured and analyzed. Results indicated that there were similar patterns of variables among phases between subjects. Non-significant correlation(r=.145) between flight time(FT) and impulse was found. Also non-significant correlation(r=.119) between center of gravity(COG) and impulse was found. In conclusions, there were similar strategies in phase 1, phase 2, and phase 3 between subjects.

Analysis and Control of NPC-3L Inverter Fed Dual Three-Phase PMSM Drives Considering their Asymmetric Factors

  • Chen, Jian;Wang, Zheng;Wang, Yibo;Cheng, Ming
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1500-1511
    • /
    • 2017
  • The purpose of this paper is to study a high-performance control scheme for neutral-point-clamping three-level (NPC-3L) inverter fed dual three-phase permanent magnet synchronous motor (PMSM) drives by considering some asymmetric factors such as the non-identical parameters in phase windings. To implement this, the system model is analyzed for dual three-phase PMSM drives with asymmetric factors based on the vector space decomposition (VSD) principle. Based on the equivalent circuits, PI controllers with feedforward compensation are used in the d-q subspace for regulating torque, where the cut-off frequency of the PI controllers are set at the twice the fundamental frequency for compensating both the additional DC component and the second order component caused by asymmetry. Meanwhile, proportional resonant (PR) controllers are proposed in the x-y subspace for suppressing the possible unbalanced currents in the phase windings. A dual three-phase space vector modulation (DT-SVM) is designed for the drive, and the balancing factor is designed based on the numerical fitting surface for balancing the DC link capacitor voltages. Experimental results are given to demonstrate the validity of the theoretical analysis and the proposed control scheme.

Ageing assessment of zirconia implant prostheses by three different quantitative assessment techniques

  • Kyaw, Phyu Phyu;Pongprueksa, Pong;Anuchitolarn, Warangkana;Sirinukunwatta, Krongkarn;Suputtamongkol, Kallaya
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.253-261
    • /
    • 2019
  • PURPOSE. To evaluate the influence of cyclic loading on phase transformation of zirconia abutments and to compare the effectiveness of three different quantitative ageing assessment techniques. MATERIALS AND METHODS. Thirty two Y-TZP prostheses fabricated from two brands, InCoris ZI and Ceramill ZI, were cemented to titanium bases and equally divided into two subgroups (n=8): control group without any treatment and aged group with cyclic loading between 20 N and 98 N for 100,000 cycles at 4 Hz in distilled water at $37^{\circ}C$. The tetragonal-to-monoclinic phase transformation was assessed by (i) conventional x-ray diffraction (XRD), (ii) micro x-ray diffraction (${\mu}XRD$), and (iii) micro-Raman spectroscopy. The monoclinic-phase fractions (M%) were compared by two-way ANOVA. RESULTS. InCoris Zi presented significantly higher M% than Ceramill Zi in both control and aged groups (P<.001). Both materials exhibited significant phase transformation with monoclinicphase of 1 to 3% more in aged groups than controls for all three assessment techniques. The comparable M% was quantified by both ${\mu}XRD$ and XRD. The highest M% was assessed with micro-Raman. CONCLUSION. Cyclic loading produced significant phase transformation in tested Y-TZP prostheses. The micro-Raman spectroscopy could be used as an alternative to XRD and ${\mu}XRD$.

Characterization of EVA/PCM/Silica Compound using Silica

  • Kim, Tae-Hyun;Choi, Kyung-Man;Lee, Jong-Hwan;Choi, Myeon-Cheon;Kim, Han-Seong
    • Elastomers and Composites
    • /
    • v.56 no.2
    • /
    • pp.72-78
    • /
    • 2021
  • A phase-change material (PCM) is a material that has the ability to delay heat transfer by absorbing heat from its environment or releasing heat to its environment while its phase changes from solid to liquid or liquid to solid at a specific temperature. As it is applied, it can contribute to environmental conservation such as energy savings and carbon dioxide emission reduction. In order for a PCM to store and release heat, the volume change during its phase transition should be large, and thus a phase transition space is required. When a PCM is used as a polymer additive, it is confined within the polymer, and there is no phase transition space; thus, its ability to absorb and release heat is significantly reduced. Therefore, in this study, porous silica was used to provide EVA/PCM compounds with sufficient space for their phase transition, and to improve the compatibility between the EVA and PCM, modified silica is used: surface-modified 5 wt% silica with 3-methacryloxypropyltrimethoxysilane. The compound was prepared and compared with the silica compound. The presence or absence of the modified silica surface modification was confirmed using Fourier-transform infrared spectroscopy and thermogravimetric analysis, the heat capacity of the compound was evaluated based on a differential scanning calorimetry analysis, and its mechanical strength and morphology were determined using scanning electron microscopy.

Hyper-FET's Phase-Transition-Materials Design Guidelines for Ultra-Low Power Applications at 3 nm Technology Node

  • Hanggyo Jung;Jeesoo Chang;Changhyun Yoo;Jooyoung Oh;Sumin Choi;Juyeong Song;Jongwook Jeon
    • Nanomaterials
    • /
    • v.12 no.22
    • /
    • pp.4096-4107
    • /
    • 2022
  • In this work, a hybrid-phase transition field-effects-transistor (hyper-FET) integrated with phase-transition materials (PTM) and a multi-nanosheet FET (mNS-FET) at the 3 nm technology node were analyzed at the device and circuit level. Through this, a benchmark was performed for presenting device design guidelines and for using ultra-low-power applications. We present an optimization flow considering hyper-FET characteristics at the device and circuit level, and analyze hyper-FET performance according to the phase transition time (TT) and baseline-FET off-leakage current (IOFF) variations of the PTM. As a result of inverter ring oscillator (INV RO) circuit analysis, the optimized hyper-FET increases speed by +8.74% and reduces power consumption by -16.55%, with IOFF = 5 nA of baseline-FET and PTM TT = 50 ps compared to the conventional mNS-FET in the ultra-low-power region. As a result of SRAM circuit analysis, the read static noise margin is improved by 43.9%, and static power is reduced by 58.6% in the near-threshold voltage region when the PTM is connected to the pull-down transistor source terminal of 6T SRAM for high density. This is achieved at 41% read current penalty.

Comparison of Hazard Analysis for Medical Device System (의료기기 시스템의 해저드 분석 기법 비교)

  • Choi, Bo-yoon;Lee, Byong-gul;Han, Hyuk-soo
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.133-145
    • /
    • 2018
  • Medical systems incurred accidents may result in significant damage for human being. Therefore, performing hazard analysis is important for medical system which is to identify hazard for preventing the accidents and minimizing the potential harm. Hazard analysis that is applied medical systems are difficult to apposite selected, because difference of analysis methods and applied development lifecycle is caused by objective of hazard analysis. It is required to select appropriate hazard analysis at concept phase during development lifecycle, owing to basic requirement elicitation to mitigate or prevent hazard based on identified hazard at concept phase. In this paper, hazard analysis methods, PHA and STPA, are compared at concept phase in which both methods have been applied on the medical system. As a result of compared methods, hazard analyst can be selected optimized hazard analysis methods for concept phase of the medical systems.

Design and analysis of direction indicating algorithm for sound reception system based on spectral analysis of whistle signal (기적신호의 스펙트럼 분석을 통한 음향수신장치의 방향탐지 알고리즘 설계 및 분석)

  • Kwon, Hyuk-Jin;Kim, Jeong-Chang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.83-90
    • /
    • 2017
  • In this paper, a sound reception system using a phase difference of whistle signals is proposed and analyzed based on spectral analysis. The proposed system receives whistle signals from four microphones installed in four different directions with 90-degree intervals between them. The proposed algorithm detects the phase of each received signal based on spectral analysis and estimates the direction of the whistle signal by obtaining the phase difference between the received signals from two adjacent microphones. Furthermore, we theoretically analyze the phase difference between two adjacent received signals according to their arrival angles and implement the proposed system using a DSP chip. In addition, the operation of the proposed algorithm are verified using the implemented system in a laboratory environment. Experimental results show that the proposed scheme can well estimate the direction of the whistle signal.

UNCERTAINTY AND SENSITIVITY ANALYSIS OF TMI-2 ACCIDENT SCENARIO USING SIMULATION BASED TECHNIQUES

  • Rao, R. Srinivasa;Kumar, Abhay;Gupta, S.K.;Lele, H.G.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.807-816
    • /
    • 2012
  • The Three Mile Island Unit 2 (TMI-2) accident has been studied extensively, as part of both post-accident technical assessment and follow-up computer code calculations. The models used in computer codes for severe accidents have improved significantly over the years due to better understanding. It was decided to reanalyze the severe accident scenario using current state of the art codes and methodologies. This reanalysis was adopted as a part of the joint standard problem exercise for the Atomic Energy Regulatory Board (AERB) - United States Regulatory Commission (USNRC) bilateral safety meet. The accident scenario was divided into four phases for analysis viz., Phase 1 covers from the accident initiation to the shutdown of the last Reactor Coolant Pumps (RCPs) (0 to 100 min), Phase 2 covers initial fuel heat up and core degradation (100 to 174 min), Phase 3 is the period of recovery of the core water level by operating the reactor coolant pump, and the core reheat that followed (174 to 200 min) and Phase 4 covers refilling of the core by high pressure injection (200 to 300 min). The base case analysis was carried out for all four phases. The majority of the predicted parameters are in good agreement with the observed data. However, some parameters have significant deviations compared to the observed data. These discrepancies have arisen from uncertainties in boundary conditions, such as makeup flow, flow during the RCP 2B transient (Phase 3), models used in the code, the adopted nodalisation schemes, etc. In view of this, uncertainty and sensitivity analyses are carried out using simulation based techniques. The paper deals with uncertainty and sensitivity analyses carried out for the first three phases of the accident scenario.

Avantor® ACE® Wide Pore HPLC Columns for the Separation and Purification of Proteins in Biopharmaceuticals (바이오의약품의 단백질 분리 및 정제를 위한 Avantor® ACE® 와이드 포어 HPLC 컬럼 가이드)

  • Matt James;Mark Fever;Tony Edge
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.3.1-3.7
    • /
    • 2024
  • The article discusses the critical role of chromatography in the analysis and purification of proteins in biopharmaceuticals, emphasizing the importance of comprehensive characterization for ensuring their safety and efficacy. It highlights the use of Avantor® ACE® HPLC columns for the separation and purification of proteins, focusing on the analysis of intact proteins using reversed-phase liquid chromatography (RPLC) with fully porous particles. This article also details the application of different mobile phase additives, such as TFA and formic acid, and emphasizes the advantages of using type B ultra-pure silica-based columns for efficiency and peak shape in biomolecule analysis. Additionally, it addresses the challenges of analyzing intact proteins due to slow molecular diffusion and introduces the concept of solid-core (or superficially porous) particles, emphasizing their benefits over traditional porous particles for the analysis of therapeutic proteins. Furthermore, it discusses the development of Avantor® ACE® UltraCore BIO columns, specifically designed for the high-efficiency separation of large biomolecules, such as proteins, and demonstrates their effectiveness in achieving high-resolution separations, even for higher molecular weight proteins like monoclonal antibodies (mAbs). In addition, it underscores the complexity of analyzing and characterizing intact protein biopharmaceuticals, requiring a range of analytical techniques and the use of wide-pore stationary phases, operated at elevated temperatures and with relatively shallow gradients. It highlights the comprehensive range of options offered by Avantor® ACE® wide pore columns, including both fully porous and solid-core particles, bonded with a variety of complementary stationary phase chemistries to optimize selectivity during method development. The use of ultrapure and highly inert base silica is emphasized for enabling the use of lower concentrations of mobile phase modifiers without compromising analyte peak shape, particularly beneficial for LC-MS applications. Then the article concludes by emphasizing the significance of reversed-phase liquid chromatography and its compatibility with mass spectrometry as a valuable tool for the separation and analysis of intact proteins and their closely related variants in biopharmaceuticals.

  • PDF

FAULT TREE ANALYSIS OF KNICS RPS SOFTWARE

  • Park, Gee-Yong;Koh, Kwang-Yong;Jee, Eunk-Young;Seong, Poong-Hyun;Kwon, Kee-Choon;Lee, Dae-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.397-408
    • /
    • 2008
  • This paper describes the application of a software fault tree analysis (FTA) as one of the analysis techniques for a software safety analysis (SSA) at the design phase and its analysis results for the safety-critical software of a digital reactor protection system, which is called the KNICS RPS, being developed in the KNICS (Korea Nuclear Instrumentation & Control Systems) project. The software modules in the design description were represented by function blocks (FBs), and the software FTA was performed based on the well-defined fault tree templates for the FBs. The SSA, which is part of the verification and validation (V&V) activities, was activated at each phase of the software lifecycle for the KNICS RPS. At the design phase, the software HAZOP (Hazard and Operability) and the software FTA were employed in the SSA in such a way that the software HAZOP was performed first and then the software FTA was applied. The software FTA was applied to some critical modules selected from the software HAZOP analysis.