• 제목/요약/키워드: Phase Compensate

검색결과 478건 처리시간 0.022초

Voltage Sag 보상을 위한 승압형 단상 인버터 시스템에 관한 연구 (A Study on Boost Type Single-Phase Inverter System for Compensation of Voltage Sag)

  • 서영민;이승용;홍순찬
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.50-57
    • /
    • 2011
  • This paper proposes a boost type single-phase inverter system to compensate the voltage sag appeared on source side. The proposed system is composed of a boost converter, a PWM inverter, and a bypass diode. If the voltage sag has appeared in input voltage, the boost converter would be operated to compensate it in the proposed system. The boost converter would not be operated when the magnitude of input voltage is more than 0.9 pu. The output voltage is kept constant by a direct-quadrature frame controller in the inverter. A 300 W class boost type inverter system was simulated, and the validity of the proposed system was verified by carrying out experiments.

순간전압강하 보상을 위한 저가의 승압형 단상 인버터 시스템의 설계 및 구현 (Design and Implementation of Low Cost Boost Type Single-Phase Inverter System for Compensation of Voltage Sag)

  • 이승용;홍순찬
    • 전력전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.85-92
    • /
    • 2012
  • In this paper, a 300[W] class boost type single-phase inverter system which can compensate voltage sag on source side is designed and implemented. This system is a two-stage conversion system composed of a boost converter and a PWM inverter. If the voltage sag has appeared at the point of common coupling, the boost converter would be operated to compensate it. The boost converter and the inverter were constructed on single smart power module(SPM) to implement low cost system. The system is designed for that the THD of output voltage is below 5[%]. Finally, the validity of the design for the inverter system is verified by both simulations and experiments.

리액턴스 효과를 최소한 병행 2회선 송전선로 보호 거리계전 알고리즘 (A Distance Relaying Algorithms Immune to Reactance Effect for Double-Circuit Transmission Line Systems)

  • 안용진;강상희;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.38-44
    • /
    • 2001
  • For double-circuit transmission line systems, an accurate digital distance relaying algorithm immune to the reactance effect is proposed. The apparent impedance calculated by the distance relay is influenced by the combined reactance effect of the fault resistance and the load current as well as the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit. To compensate the magnitude and phase of the estimated impedance, this algorithm uses phase angle difference between the zero(positive) sequence of the both side of the system seperated by the fault point. The impedance measuring algorithm presented used a current distribution factor to compensate mutual coupling effect instead of the collected zero-sequence current of the adjacent parallel circuit.

  • PDF

Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer) 개발 (Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method)

  • 정종규;한병문
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1954-1961
    • /
    • 2009
  • This paper describes the development of a three-phase line-interactive dynamic voltage restorer with hybrid detection method, which is composed of three H-bridge inverter modules and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 3kVA prototype. The developed system can compensate the input voltage sag and interruption within 2ms. The maximum allowable duration of voltage interruption is about 4 seconds. The developed system can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication devices, and automation devices, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components, and to be highly reliable in operation.

3상 UPS용 인버터의 강인한 비간섭 디지털제어 (Robust Decoupling Digital Control of Three-Phase Inverter for UPS)

  • 박지호;허태원;신동렬;노태균;우정인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.246-255
    • /
    • 2000
  • This paper deals with a novel full digital control method of the three-phase PWM inverter for UPS. The voltage and current of output filter capacitor as state variables are the feedback control input. In addition, a double deadbeat control consisting of a d-q current minor loop and a d-q voltage major loop, both with precise decoupling, have been developed. The switching pulse width modulation based on SVM is adopted so that the capacitor current should be exactly equal to its reference current. In order to compensate the calculation time delay, the predictive control is achieved by the current·voltage observer. The load prediction is used to compensate the load disturbance by disturbance observer with deadbeat response. The experimental results show that the proposed system offers an output voltage with THD less than 2% at a full nonlinear load.

  • PDF

3상 PWM 인버터를 이용한 순간전압보상기의 해석 (Analysis of Instantaneous Voltage Compensator Using 3-Phase PWM Inverter)

  • 최연규;이승요;최규하;목형수;함형원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.222-227
    • /
    • 1997
  • Unbalanced source voltages due to unbalanced loads in the 3-phase power system is decomposed into positive, negative and zero sequence components. Also, assuming there is no neutural path in the system, the zero sequence component is not shown. Therefore, it is possible to compensate unbalanced source voltage by canceling the negative sequency component of the voltages of the source. In this paper, an algorithm compensating unbalanced source voltages by canceling the negative sequence component is presented and analysis of instantaneous voltage compensator using 3-phase PWM inverter is carried out through computer simulation.

  • PDF

3상 계통에서 전류/전압과 순시전력간의 맵핑이론 (The Mapping Theory between Current/Voltage and Instantaneous Powers in Three-phase Systems)

  • 김효성;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.228-232
    • /
    • 1997
  • The relation between instantaneous active/reactive powers and currents is defined by voltage mapping matrix in three-phase four-wire systems. Control strategies for an active filter without energy storage components are proposed on the basis of mapping matrices. It can compensate for the zero-sequence current, irrespectively of whether or not a zero-sequence voltage exists in a three-phase four-wire system.

  • PDF

FUNDAMENTAL RESEARCH OF A NOVEL 3/1 PHASE CONVERTER FOR ELECTRIFIED RAILROAD

  • Farshad, Siamak;Rongtai, Hao
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.955-960
    • /
    • 1998
  • Electrified railroads inject large amount of harmonics, negative sequence and reactive currents to electric supply systems. This paper introduces application of active filter as a 3/1 phase converter for electrified railroad. In this system active filter compensate harmonics, negative sequence and reactive currents and electric railroad and active filter together act as a balance three-phase load with power factor 1

  • PDF

고장저항의 영향을 최소화한 거리계전기법 (A Digital Distance Relaying Algorithm Immune to Fault Resistance)

  • 안용진;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.286-288
    • /
    • 1998
  • A digital distance relaying algorithm immune to the effect of the fault resistance in single-phase to ground fault is proposed. The power frequency components of relaying signals are extracted by the 1 cycle DFT. To compensate the magnitude and phase of the estimated impedance, which is calculated by the general method, this algorithm uses phase difference between the zero sequence impedance of networks on both sided of the system.

  • PDF

3상 무정전 전원장치에 적합한 새로운 구조의 동기좌표계 전압제어기 (Advanced Synchronous Reference Frame Controller for three-Phase UPS Powering Unbalanced and Nonlinear Loads)

  • 현동석;김경환
    • 전력전자학회논문지
    • /
    • 제10권5호
    • /
    • pp.508-517
    • /
    • 2005
  • 본 논문은 LC 필터를 갖는 3상 인버터에 적합한 고성능 전압제어기에 대해서 기술한다. 불평형 부하 및 비선형 부하시 3상 인버터의 출력전압 왜곡을 동시에 보상 할 수 있는 새로운 동기좌표계 전압제어기를 제안한다. 제안된 제어기는 전용의 디지털 필터를 사용하여 불평형 및 비선형 부하 상태하에서도 동기좌표계의 PI 전압제어기가 3상 평형의 선형부하에서와 같이 직류값을 가지고 동작하게 함으로써 비록 전압제어기의 대역폭이 높지 않아도 정상상태 오차를 현격히 감소시킨다. 제안한 제어기의 성능의 타당성을 입증하기 위해서 모의실험 결과를 보였으며 실험을 통하여 모의실험 결과를 확인하였다.