• Title/Summary/Keyword: Phase Calibration

Search Result 501, Processing Time 0.034 seconds

Error analysis and Performance test of the Volumetric interferometer for Absolute distance measurement (삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가)

  • Rhee, H.G.;Chu, J.Y.;Kim, S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.387-390
    • /
    • 2002
  • In this paper, we accomplish uncertainty evaluation and performance test of the volumetric interferometer using two spherical wavefronts emitted from the ends of two single mode fibers. We verify that the volumetric interferometer has the volume uncertainty of 690nm through the error analysis and it has the resolution of 0.1 0.1$\mu\textrm{m}$ for x axis which is the same order of repeatability for x axis. Also, we obtain the systematic error of $1\mu\textrm{m}$ for $60\times 60\times 20 mm^3$ working volume using self-calibration with an artifact plate.

  • PDF

Fiber Fabry-Perot type Optical Current Transducer with Frequency Ramped Signal Processing Scheme

  • Park, Youn-Gil;Seo, Wan-Seok;Lee, Chung-E.;Taylor, Henry-F.
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.74-79
    • /
    • 1998
  • The use of a fiber Fabry-Perot interferometer (FFPI) as an optical current transducer is demonstrated. A conventional inductive pickup coil converts the time-varying current I(t) being measured to a voltage waveform V(t) applied across a piezeolectric strip to which the FFPI is bonded. The strip experiences a longitudinal expansion and contraction, resulting in an optical phase shift ${\phi}(t)$ in the fiber proportional to V(t). This phase shift is measured using a frequency-modulated semiconductor light source, photodiodes to monitor the reflected light from the FFPI and the laser power, and a digital signal processor. Calibration routines compute V(t) and I(t) from the measured phase shift at a l KHz rate. Response to 60 Hz ac over the design range 0-1300A rms is characterized Transient response of the FFPI transducer is also measured.

On-Site Calibration Technology of Burden using Voltage Transformer Comparator (전압변성기 비교기를 이용한 부담의 현장교정 기술)

  • Jung, Jae Kap;Kwon, Sung Won;Park, Young Tae;Kim, Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.503-507
    • /
    • 2005
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of VT burden used. Thus, precise measurement of burden is very important for the evaluation of VT. A method of evaluation for VT burden has been developed by employing the portable decade resistor, with AC-DC resistance difference less than 10-3. The burden value(value and power factor) can be obtained by conductance and susceptance, obtained by measuring the change of ratio error and phase angle error caused by the resistance change of decade resistor. The burden value and power factor obtained by the method are consistent with those obtained using power analyzer within corresponding uncertainties.

A study of Three Dimension Shape Measurement by PS(Phase-Shift) (PS(Phase Shift)방법을 이용한 3차원 형상 측정에 대한 연구)

  • Lee, Hye-In;Kim, Hye-Jin;HwanBo, Seong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1784-1785
    • /
    • 2011
  • PS(Phase Shift) 방식을 이용하여 3차원 이미지 형상복원 시스템을 구현하였다. PS 방식은 위상을 이동시켜서 얻어진 강도를 arctan 시킴으로써 $-{\pi}{\sim}{\pi}$ 범위의 접혀진(wrapped) 위상을 얻을 수 있으며, 이러한 wrapped 위상을 위상 펼침(unwrapping) 알고리즘을 이용하여 불연속을 제거할 수 있다. 얻어진 위상 정보는 물체의 높이 정보에 비례하기 때문에 위상 분포로써 3차원 형상을 복원할 수 있다. Unwrapping 알고리즘에는 다양한 방식이 있지만 본 연구에서는 LabVIEW 프로그램을 이용하여 Goldstein 알고리즘을 구현하였으며, 감마(Gamma) 효과에 의한 노이즈를 줄이기 위하여 프로젝트와 카메라의 보정(calibration) 프로그램을 개발 및 적용하였다. 이와 같은 실험을 통하여 효과적으로 3차원 형상 정보를 얻을 수 있었다.

  • PDF

Quantitation and Validation of Atorvastatin using HPLC-UV

  • Heine, Daniel;Yong, Chul-Soon;Kim, Jung-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.187-192
    • /
    • 2007
  • A reversed phase HPLC analysis of atorvastatin (AS) standard solution was performed using diclofenac (DF) as internal standard. Column oven temperature, flow rate and the composition of the mobile phase were varied in order to determine a practical system setup using a C18 column and UV detector. Two C18 columns of different length were compared regarding their influence on the AS peak shape. Based on these preliminary experiments a validation study was performed utilizing a C18 column at $62^{\circ}C$ with a mobile phase consisting of sodium phosphate buffer (0.05 M, pH 4.0), methanol and acetonitrile (40:50:10, v/v/v). The detection limit for AS was $0.1{\mu}g/ml$ and inter- and intra-day calibration curves were linear over a concentration range of $0.2-50{\mu}g/ml$. Accuracy and precision were satisfactory in the AS concentration range of $0.5-50{\mu}g/ml$.

Determination of Grayanotoxin I and Grayanotoxin III in mad honey from Nepal using liquid chromatography-tandem mass spectrometry

  • Ahn, Su Youn;Kim, Suncheun;Cho, Hwangeui
    • Analytical Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.82-91
    • /
    • 2022
  • Grayanotoxin-contaminated honey exhibits toxicity. In this study, a reliable and sensitive liquid-chromatography-tandem-mass-spectrometric method (LC-MS/MS) was developed and validated for the quantitation of grayanotoxin I and grayanotoxin III in honey. The grayanotoxins were extracted from honey via solid phase extraction and separated on a biphenyl column with a mobile phase consisting of 0.5 % acetic acid in water and methanol. Mass spectrometric detection was performed in the multiple-reaction monitoring mode with positive electrospray ionization. The calibration curve covered the range 0.25 to 100 ㎍/g. The intra- and inter-day deviations were less than 10.6 %, and the accuracy was between 94.3 and 114.0 %. The validated method was successfully applied to the determination of grayanotoxins in mad honey from Nepal. The concentrations of grayanotoxin I and grayanotoxin III in 33 out of 60 mad honey samples were 0.75 - 64.86 ㎍/g and 0.25 - 63.99 ㎍/g, respectively. The method established herein would help in preventing and confirming grayanotoxin poisoning.

Mission Operation Capability Verification Test for Low Earth Orbit(LEO) Satellite by Utilizing Interface Environment between LEO Satellite and Ground Station (저궤도 위성과 지상국간 접속 환경을 활용한 임무수행능력 지상 검증 시험)

  • Lee, Sang-Rok;Koo, In-Hoi;Lim, Seong-Bin
    • Aerospace Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.142-149
    • /
    • 2014
  • After launch of Low Earth Orbit(LEO) satellite, Initial Activation Checkout(IAC) and Calibration and Validation(Cal & Val) procedure are performed prior to enter normal operation phase. During normal operation phase, most of the time is allocated for mission operation except following up measures to anomaly and orbit maintenance. Since mission operation capability is key indicator for success of LEO satellite program and consistent with promotion purpose of LEO satellite program, reliability should be ensured by conducting through test. In order to ensure reliability by examining the role of LEO satellite and ground station during ground test phase, realistic test scenario that is similar to actual operation conditions should be created, and test that aims to verify full mission cycle should be performed by transmitting created command and receiving image and telemetry data. This paper describes the test design and result. Consideration items for test design are described in detail and result of designed test items are summarized.

Error analysis and performance test of the volumetric interferometer for three dimensional coordinate measurements (삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가)

  • 이혁교;주지영;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.521-529
    • /
    • 2002
  • We have recently proposed the new concept of a phase-measuring volumetric interferometer that enables us to accurately measure the xyz-coordinates of the probe without metrology frames. The interferometer is composed of a movable target and a fixed photo-detector array. The target is made of point diffraction sources to emit two spherical wavefronts, whose interference is monitored by an array of photo-detectors. Phase shifting is applied to obtain the precise phase values of the photo-detectors. Then the measured phases are fitted to a geometric model of multilateration so as to determine the xyz-location of the target by minimizing least square errors. The proposed interferometer has been designed and built with a volumetric uncertainty of less than 1.0 $\mu\textrm{m}$ within a cubic working volume of side 120 mm. Here, in this paper, we also present error sources, an evaluated uncertainty, and test results from the prototype system. The self-calibration of two-dimensional precision metrology stages is applied to test the performance of the interferometer.

Korea Pathfinder Lunar Orbiter Magnetometer Instrument and Initial Data Processing

  • Wooin Jo;Ho Jin;Hyeonhu Park;Yunho Jang;Seongwhan Lee;Khan-Hyuk Kim;Ian Garrick-Bethell;Jehyuck Shin;Seul-Min Baek;Junhyun Lee;Derac Son;Eunhyeuk Kim
    • Journal of Astronomy and Space Sciences
    • /
    • v.40 no.4
    • /
    • pp.199-215
    • /
    • 2023
  • The Korea Pathfinder Lunar Orbiter (KPLO), the first South Korea lunar exploration probe, successfully arrived at the Moon on December, 2022 (UTC), following a 4.5-month ballistic lunar transfer (BLT) trajectory. Since the launch (4 August, 2022), the KPLO magnetometer (KMAG) has carried out various observations during the trans-lunar cruise phase and a 100 km altitude lunar polar orbit. KMAG consists of three fluxgate magnetometers capable of measuring magnetic fields within a ± 1,000 nT range with a resolution of 0.2 nT. The sampling rate is 10 Hz. During the originally planned lifetime of one year, KMAG has been operating successfully while performing observations of lunar crustal magnetic fields, magnetic fields induced in the lunar interior, and various solar wind events. The calibration and offset processes were performed during the TLC phase. In addition, reliabilities of the KMAG lunar magnetic field observations have been verified by comparing them with the surface vector mapping (SVM) data. If the KPLO's mission orbit during the extended mission phase is close enough to the lunar surface, KMAG will contribute to updating the lunar surface magnetic field map and will provide insights into the lunar interior structure and lunar space environment.

Evaluation of multi-objective PSO algorithm for SWAT auto-calibration (다목적 PSO 알고리즘을 활용한 SWAT의 자동보정 적용성 평가)

  • Jang, Won Jin;Lee, Yong Gwan;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.9
    • /
    • pp.803-812
    • /
    • 2018
  • The purpose of this study is to develop Particle Swarm Optimization (PSO) automatic calibration algorithm with multi-objective functions by Python, and to evaluate the applicability by applying the algorithm to the Soil and Water Assessment Tool (SWAT) watershed modeling. The study area is the upstream watershed of Gongdo observation station of Anseongcheon watershed ($364.8km^2$) and the daily observed streamflow data from 2000 to 2015 were used. The PSO automatic algorithm calibrated SWAT streamflow by coefficient of determination ($R^2$), root mean square error (RMSE), Nash-Sutcliffe efficiency ($NSE_Q$), and especially including $NSE_{INQ}$ (Inverse Q) for lateral, base flow calibration. The results between automatic and manual calibration showed $R^2$ of 0.64 and 0.55, RMSE of 0.59 and 0.58, $NSE_Q$ of 0.78 and 0.75, and $NSE_{INQ}$ of 0.45 and 0.09, respectively. The PSO automatic calibration algorithm showed an improvement especially the streamflow recession phase and remedied the limitation of manual calibration by including new parameter (RCHRG_DP) and considering parameters range.