• 제목/요약/키워드: Phase

검색결과 47,279건 처리시간 0.396초

커뮤테이션 구간의 토크리플 저감을 위한 SRM의 토크 분배 함수 기법 (Torque Sharing Function of SRM for Torque Ripple Reduction in Commutation Region)

  • 김태형;;이동희;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.148-150
    • /
    • 2007
  • A novel torque sharing function (TSF) is presented. To improve efficiency and to reduce torque ripple in commutation region, only a phase torque under commutation is regulated to produce a uniform torque. And the torque developed by the other phase remains with the previous state under a current limit of the motor and drive. If the minimum change of a phase torque reference can not satisfy the total reference torque, two-phase changing mode is used. Since a phase torque is constant and the other phase torque is changed at each rotor position, total torque error can be reduced within a phase torque error limit. And the total torque error is dependent on the change of phase torque. To consider non-linear torque characteristics and to suppress a tail current at the end of commutation region, the incoming phase current is changed to torque increasing direction, but the outgoing phase current is changed to torque decreasing direction. So, the torque sharing of the outgoing phase and incoming phase can be smoothly changed with a minimum current cross over. The proposed control scheme is verified by some computer simulations and experimental results.

  • PDF

Single-Phase Z-Source AC/AC Converter with Wide Range Output Voltage Operation

  • Nguyen, Minh-Khai;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.736-747
    • /
    • 2009
  • A new type of single-phase Z-source AC/AC converter based on a single-phase matrix converter is proposed in this paper. The proposed single-phase Z-source AC/AC converter has unique features; namely that the output voltage can be bucked and in-phase/out-of-phase with the input voltage; that the output voltage can be boosted and in-phase/out-of-phase with the input voltage. The converter employs a safe-commutation strategy to conduct along a continuous current path, which results in the elimination of voltage spikes on switches without the need for a snubber circuit. The operating principles of the proposed single-phase Z-source AC/AC converter are described, and a circuit analysis is provided. To verify the performance of the proposed converter, a laboratory prototype based on a TMS320F2812 DSP was constructed. The simulation and the experimental results verified that the output voltage can be bucked-boosted and in-phase with the input voltage, and that the output voltage can be bucked-boosted and out-of-phase with the input voltage.

RHTL과 LHTL 형태의 위상변위기를 이용한 주파수 변환기 성능비교 (The Performance Comparison of Frequency Translators Using RHTL and LHTL Phase Shifters)

  • 한희제;박홍우;김홍준
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.371-375
    • /
    • 2014
  • In this paper, we compared the performances of the Right Handed Transmission Line (RHTL) and the Left Handed Transmission Line (LHTL) phase shifters as a frequency translator. Unlike other phase shifters, both phase shifters show a $0^{\circ}-360^{\circ}$ phase variation for a broadband frequency and compact in size which are ideal to use as a frequency translator. For the performance comparison, we fabricated both a RHTL and a LHTL phase shifter to cover 1.5 GHz - 2.4 GHz range with the whole $360^{\circ}$ phase variation. For the frequency range, a LHTL based frequency translator showed a much better performance whose Spurious Free Dynamic Range (SFDR) is 4dB - 17dB higher than the RHTL based frequency translator when the sawtooth modulation freqncy is 11 kHz. This is due to the linear phase-voltage variation of LHTL phase shifter. Furthermore, the LHTL phase shifter shows a less insertion loss and a insertion loss variation than the RHTL phase shifter. Overall, the LHTL based frequency translator outperformed RHTL based freqency translator.

토크분배함수를 이용한 SRM의 적접토크제어기법 (Direct Torque Control Scheme of Switched Reluctance Motor using Novel Torque Sharing Function)

  • 안진우;이동희;김태형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.138-140
    • /
    • 2007
  • A novel non-linear logical torque sharing function (TSF) is presented. To improve efficiency and to reduce torque ripple in commutation region, only a phase torque under commutation is regulated to produce a uniform torque. And the torque developed by the other phase remains with the previous state under a current limit of the motor and drive. If the minimum change of a phase torque reference can not satisfy the total reference torque, two-phase changing mode is used. Since a phase torque is constant and the other phase torque is changed at each rotor position, total torque error can be reduced within a phase torque error limit. And the total torque error is dependent on the change of phase torque. To consider non-linear torque characteristics and to suppress a tail current at the end of commutation region, the incoming phase current is changed to torque increasing direction, but the outgoing phase current is changed to torque decreasing direction. So, the torque sharing of the outgoing phase and incoming phase can be smoothly changed with a minimum current cross over. The proposed control scheme is verified by some computer simulations and experimental results.

  • PDF

저압 모의선로에 소형발전원 연계시 특성 (Connected Characteristics for Small Generation Source of Low Voltage Model Grids)

  • 이상우;강진규;이동하;박태준
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the typical phase voltage and line current waveform characteristics of the distribution system with 3 phase small synchronous generation source in case with load and non-load group, in order to investigate the power quality for end load connected of generation source. As demonstrated by our experimental results, the distortion and power quality of phase voltage and line current waveform were relatively good for low voltage 3 phase model grids connected of 3 phase small synchronous generation source in case with non-load group. However, distortion and power quality of voltage and current waveform was poor for low voltage 3 phase model grids connected to 3 phase small synchronous generation source in the load group with some phase voltage and frequency difference. From the above results, we conclude that the phase voltage and frequency of 3 phase generation source must be identical to that of distribution system source to maximize the power quality. Also, special attention is required in case of having load group or non-load group to 3 phase generation source.

A Novel Single Phase Synchronous Reference Frame Phase-Locked Loop with a Constant Zero Orthogonal Component

  • Li, Ming;Wang, Yue;Fang, Xiong;Gao, Yuan;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1334-1344
    • /
    • 2014
  • A novel single phase Phase-Locked Loop (PLL) is proposed in this paper to accurately and rapidly estimate the instantaneous phase angle of a grid. A conjugate rotating vector pair is proposed and defined to synthesize the single phase signal in the stationary reference frame. With this concept, the proposed PLL innovatively sets one phase input of the PARK transformation to a constant zero. By means of a proper cancellation, a zero steady state phase angle estimation error can be achieved, even under magnitude and frequency variations. The proposed PLL structure is presented together with guidelines for parameters adjustment. The performance of the proposed PLL is verified by comprehensive experiments. Satisfactory phase angle estimation can be achieved within one input signal cycle, and the estimation error can be totally eliminated in four input cycles for the most severe conditions.

3상 위상제어 정류기에서 DVR의 응답시간과 허용 가능한 순시저전압의 범위에 대한 연구 (A study on the permissible range of voltage dips and the response time of DVR in 3-phase phase-controlled rectifier)

  • 한무호;권우현;박철우
    • 제어로봇시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.325-333
    • /
    • 2004
  • It is investigated that the relation between the response time of DVR(Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system which protects the 3-phase phase-controlled rectifier from voltage dip. As a result, the permissible range of voltage dip is presented in the 3-phase phase-controlled rectifier, and it is presented that the range of voltage dip which can be compensated according to the DVR s response time. when the DVR compensates voltage dip, Using the proposed method, the DVR s response time can be determined from the parameters of 3-phase phase-controlled rectifier and the possible compensation range of voltage dip, and it is possible to use the control system which have an appropriate speed. Therefore, the use of excessively fast device can be avoided, and the stability of the overall system is improved. Also the reliance of DVR about the 3-phase phase-controlled rectifier can be verified.

이상 이축 하중 하에서 구멍 주위에서의 피로 균열 발생 (Fatigue Crack Initiation around a Hole under Out-of-phase Biaxial Loading)

  • 허용학;박휘립;김동진
    • 대한기계학회논문집A
    • /
    • 제27권10호
    • /
    • pp.1695-1702
    • /
    • 2003
  • Fatigue crack initiation around a hole subjected to biaxial fatigue loads with a phase difference was investigated. Axial and torsional biaxial fatigue loads with different phase differences and biaxiality of 1/√3 were applied to thin-walled tubular specimens. Five phase differences of 0, 45, 90, 145 and 180 degrees were selected. Directions of the fatigue crack initiation around the hole were found to approach to the circumferential direction of the specimen with increment of the phase difference for fatigue tests with phase differences less than 90$^{\circ}$. Whereas directions for tests with phase differences greater than 90$^{\circ}$ got away from the circumferential direction and those were symmetric to the directions for tests with phase difference less than 90. . Furthermore, it was shown that the fatigue initiation life decreased with increment of phase difference for fatigue tests with phase differences less than 90$^{\circ}$, but it increased for tests with phase difference greater than 90$^{\circ}$. The crack initiation direction can be successfully explained by using the direction of the maximum tangential stress range obtained around the hole and at far-field.

3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성 시뮬레이션 (Simulation of Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL)

  • 임성훈;박충렬;한병성;박형민;조용선;최효상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.167-168
    • /
    • 2005
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-Tc superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF

힐버트 변환을 이용한 디지털 위상천이기의 성능 분석 (Performance Analysis of digital phase shifter using Hilbert transform)

  • 서상규;정봉식
    • 융합신호처리학회논문지
    • /
    • 제14권1호
    • /
    • pp.39-44
    • /
    • 2013
  • 본 논문에서는 멀티암(multi-arm) 스파이럴 안테나용 디지털 위상천이기(digital phase-shifter)를 힐버트 변환(Hillbert transform)을 이용하여 설계하였다. 힐버트 변환은 입력신호에 포함된 모든 주파수 성분을 $90^{\circ}$ 위상천이 시키며, 퓨리에 변환(Fourier transform)과 역퓨리에 변환(Inverse FIT)을 통해 구현된다. 디지털 위상천이기는 ADC(Analog-digital converter)로 샘플링된 입력신호에 힐버트 변환을 적용하여 위상차가 $90^{\circ}$인 두 신호를 생성하고, 이 두 신호를 이용하여 입력신호의 위상을 천이위상만큼 천이시키게 한다. 힐버트 변환 기반의 디지털 위상천이기는 Xilinx사의 System generator로 설계되었고, 입력 잡음, FFT 포인트 수, 샘플링 주기, 입력신호의 초기위상 및 천이 위상각 등에 따른 위상천이 성능을 시뮬레이션 하였으며, Matlab 결과와 비교하여 일치함을 확인하였다.