Pet Care and Internet Consumption (반려동물 돌봄과 인터넷 소비)

  • Han, Hee-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.9
    • /
    • pp.388-400
    • /
    • 2022
  • This study analyzed the Internet consumption behavior concerning pet care through in-depth interviews with 11 people who take care of pets. In this study, along with owners of domestic companion animals, stray cat caregivers were included as pet consumers, which have not yet been included in this category in existing research. Internet consumption was found to differ between people with dogs and people with cats. In the case of dog owners, they bought a lot of bath products, clothes harnesses, and strollers that were not appropriate for cats. Although the pet-poor phenomenon is known to occur a lot among young consumers, who care for pets behavior at the cost of money spent on themselves, even stray cat caregivers, mostly middle-aged women, are wary of becoming pet-poor. It cannot be said that there are gender differences in online shopping of pet consumers. In general, women, who did mainly Internet shopping, and if they are not used to using the Internet, their husbands made purchases online instead.

Diagnostic Performance and Prognostic Relevance of FDG Positron Emission Tomography/Computed Tomography for Patients with Extrahepatic Cholangiocarcinoma

  • Nam Hee Kim;Sung Ryol Lee;Young Hwan Kim;Hong Joo Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1355-1366
    • /
    • 2020
  • Objective: We aimed to evaluate the diagnostic value and prognostic relevance of FDG positron emission tomography/computed tomography (PET-CT) in extrahepatic cholangiocarcinoma patients. Materials and Methods: This study included 234 extrahepatic cholangiocarcinoma patients who underwent FDG PET-CT between June 2008 and February 2016. The diagnostic performance of FDG PEG-CT was compared to that of contrast-enhanced multidetector row CT (MDCT) and MRI. Independent prognosticators for poor survival were also assessed. Results: The sensitivity of FDG PET-CT for detecting primary tumor and regional lymph node metastases was lower than that of MDCT or MRI (p < 0.001), whereas the specificity and positive predictive value for detecting regional lymph nodes metastases was significantly better in FDG PET-CT compared to MDCT and MRI (all p < 0.001). There was no significant difference in the diagnostic yield of distant metastases detection among three diagnostic imaging techniques. In a multivariate analysis, maximum standardized uptake values (SUVmax) of the primary tumor (adjusted hazard ratio [HR], 1.75; 95% confidence interval [CI], 1.13-2.69) and of the metastatic lesions ≥ 5 (adjusted HR, 8.10; 95% CI, 1.96-33.5) were independent contributors to poor overall survival in extrahepatic cholangiocarcinoma patients. In a subgroup analysis of 187 patients with periductal infiltrating type of cholangiocarcinoma, an SUVmax of the primary tumor ≥ 5 was associated with an increased risk of regional lymph node (adjusted odds ratio [OR], 1.60; 95% CI, 0.55-4.63) and distant metastases (adjusted OR, 100.57; 95% CI, 3.94-2567.43) at diagnosis as well as with poor overall survival (adjusted HR, 1.81; 95% CI, 1.04-3.15). Conclusion: FDG PET-CT showed lower sensitivity for detecting primary tumor and regional lymph node involvement than MDCT and MRI. However, the SUVmax of primary tumors and metastatic lesions derived from FDG PET-CT could have significant implications for predicting prognoses in extrahepatic cholangiocarcinoma patients.

Combined PET/CT in Oncology (종양핵의학에서 PET/CT의 역할)

  • Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.80-86
    • /
    • 2002
  • Presently, PET is widely used in oncology, but suffers from limitations of poor anatomical information. To compensate for this weakness, a combined PET/CT has been developed by Professor Townsend at the University of Pittsburgh Medical Center. The prototype was designed as PET and CT components combined serially in a gantry. The CT images provide not only accurate anatomical location of the lesions but also transmission map for attenuation correction. More than 300 cancer patients have been studied with the prototype of PET/CT since July, 1998. The PET/CT studies affected the managements in about $20{\sim}30%$ of cancer patients. These changes are a consequence of the more accurate localization of functional abnormalities, and the distinction of pathological from normal physiological uptake. Now a variety of combined PET/CT scanners with high-end PET and high-end CT components are commercially available. With the high speed of multi-slice helical CT, throughput of patient's increases compared to conventional PET. Although some problems (such as a discrepancy in breathing state between the two modalities) still remain, the role of PET/CT in oncology is very promising.

Clinical Application of $^{18}F-FDG$ PET in Pancreas Cancer (췌장암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Kang, Won-Jun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.71-75
    • /
    • 2008
  • The prevalence of pancreas cancer is increasing. Due to difficulty in detecting early stage disease, the prognosis of pancreas cancer is known to be poor. Clinical use of FDG PET in pancreas has been reported. FDG PET showed good performance in diagnosing pancreas cancer, and is expected to be useful in staging and detecting recurrence.

Graft Polymerization of Methacrylic acid onto PET Film (PET필름에 Methacrylic 산의 그라프트 중합)

  • Chung Hae Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.2
    • /
    • pp.79-84
    • /
    • 1986
  • Methacrylic acid was graft polymerized with benzoyl peroxide in itiator onto the commercial PET film. Graft polymerization was carried out in emulsion, which consisted of BPO (1), chlorobenzene(8) as swelling agent, tween 80(1) and sodium lauryl sulfate(1) as emulsifier and water(1,000). Original PET film has poor reactivities and, so the film preswdled with benzyl alcohol($150^{\circ}C$, 1hr) was also examined. The graft yield of PET film was increased with reaction temperature and monomer concentration. The graft yield of preswelled PET film was higher than that of no-treated PET film. Moisture regain was linearly increased with graft yield. DSC thermodiagram showed the Tm of grafted PET film was same as that of original PET film. Grafted PET film was dyed with methylene blue solution. The photograph of the cross section showed that grafting was occured not at the center but near surfaces.

  • PDF

Clinical Application of $^{18}F-FDG$ PET in Malignant Mesothelioma (악성중피종에서 $^{18}F-FDG$ PET의 임상응용)

  • Lee, Eun-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.157-161
    • /
    • 2008
  • Malignant pleural mesothelioma (MPM) has a poor prognosis and a strong association with exposure to asbestos. Although there are not generally accepted guidelines for treatment of MPM, recent reports suggest that multi modality therapy combining chemotherapy, radiotherapy, and surgery can improve the survival of patients with MPM. Therefore exact staging is required to decide the best treatment option. However, it is well known that there are many difficulties in determining precise preoperative stage, predicting prognosis, and monitoring response to therapy with conventional imaging modalities such as CT and MRI in MPM. Recently PET with $^{18}F-FDG$ comes into the spotlight as an important staging method. There is increasing evidence that PET is superior to other conventional imaging modalities in diagnosis and staging of MPM. Particularly PET/CT improves the diagnostic and staging accuracy over PET or CT alone in MPM because it provides anatomic imaging data as well as functional information. PET and PET/CT are also useful for monitoring response to therapy and SUV is reported as a prognostic factor in MPM.

A Study on Polypropylene and Surface Modified PET Fiber Composites (표면처리된 PET 섬유와 PP 복합재료에 관한 연구)

  • Hahm, Moon-Seok;Kim, Chang-Hyeon;Ryu, Ju-Whan
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.7-12
    • /
    • 2008
  • We confirmed that poly (ethylene terephthalate) (PET) fiber had the possibility to improve the mechanical properties of polypropylene (PP) by fabricating PP/PET fiber composites because PET enhanced mechanical properties and higher melting temperature than PP. But lower compatibility of between PP and PET fibers induced poor mechanical properties of PP/PET fiber composites in spite of incorporating PP-g-MAH as compatibilizer. To solve these problems of PP/PET fiber composites, we carried out a surface treatment on PET fiber using NaOH solution and Prepared PP/PET fiber composites with good mechanical properties by adding PP-g-MAH as a compatibilizer Then the behavior of the mechanical properties was correlated with the results obtained from SEM and IR spectroscopy.

$^{18}F-FDG-PET/CT$ in Endometrial Carcinoma (자궁내막암에서 $^{18}F-FDG-PET/CT$)

  • Jeon, Tae-Joo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.110-112
    • /
    • 2008
  • Endometrial carcinoma is one of the most common gynecologic malignancies and which is predominant in postmenopausal women. Clinically many patients are hospitalized in early stage due to clinical sign and symptom such as vaginal bleeding and in this case, patient's prognosis is known to be good. However, considerable number of patients with advanced and relapsed disease reveal poor prognosis. Therefore, exact staging work up is essential for proper treatment as is primary lesion detection. $^{18}F-FDG-PET$ has been widely used for the evaluation of gynecologic malignancies such as cervical carcinoma and ovarian cancer. In contrast, FDG PET application to endometrial carcinoma is limited until now and there is no sufficient data to validate the usefulness of FDG PET for this disease yet. However, several studies showed promising results that FDG PET is sensitive and specific in detection of recurrent or metastatic lesions. Therefore further active investigation in this field can facilitate the use of FDG PET for endometrial carcinoma.

Dyeing properties of direct spun type microfiber velvet woven fabric (직방형 이형단면 초극세사를 이용한 벨벳 직물의 염색성 및 견뢰도 평가)

  • Kim, Dong-Bin;Eom, Min-Yeong;Go, Jun-Seok
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2008.04a
    • /
    • pp.86-88
    • /
    • 2008
  • Dyeing and fastness properties of direct spun type PET microfiber velvet woven fabric have been compared with those of regular PET velvet woven fabric. They showed different exhaustion and rate of dye uptake. The build-up properties of disperse dyes on direct spun type PET microfiber velvet woven fabric were relatively poor than regular PET velvet woven fabric. The wash fastness properties of disperse dyes on regular PET velvet woven fabric were similar to direct spun type PET microfiber velvet woven fabric.

  • PDF

Preparation of Properties of PC/PBT Alloy Using MBS Compatibility (MBS상용화제를 사용한 PC/PET Alloy의 제조와 그 물성)

  • Lee, Yong-Moo;Kang, Doo-Whan
    • Applied Chemistry for Engineering
    • /
    • v.5 no.1
    • /
    • pp.54-62
    • /
    • 1994
  • Bisphenol A polycarbonate(PC) and polyethylene terephthalate(PET) was blended with methylmethacrylate-butadiene-styrene(MBS) copolymer for the improvement of impact resistance strength PC/PET alloy blending with PC more than 15 parts to 100 parts of PET usually have poor compatability, but increased the compatability characteristics of PC/PET alloy prepared by addition of MBS compatabilizer. The compatability of PC and PET using compatabilizer, MBS was determined by measuring the thermal characteristics of Tg difference between PC and PET, and crystallization temperature, Tcc. As the Tg difference becoming narrow to $60^{\circ}C$, and Tcc decreasing to $150^{\circ}C$, the comparability of PC and PET was increased. And also tough rate impact strength to PC/PET alloy using MBS was increased, in case more than 15 parts of PC being blended to PET.

  • PDF