• Title/Summary/Keyword: Personal health device

Search Result 119, Processing Time 0.027 seconds

Blood Pressure Estimation for Development of Wearable small Blood Pressure Monitor Fusion Algorithm Analysis (웨어러블 초소형 혈압계 개발을 위한 혈압 추정 융합 알고리즘 분석)

  • Kim, Seon-Chil;Kwon, Chan-Hoe;Park, You-rim
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.209-215
    • /
    • 2019
  • The most important personal health care in digital health care is a very important issue mainly for chronic diseases. Therefore, it is important to develop a simple wearable device for real-time health management. Existing blood pressure estimation wearable devices use PPG characteristics to analyze PTT and propose blood pressure estimation algorithms. However, the influencing factors of the algorithm such as the reproducibility of PPG, whether to apply various PTTs, and variables generated from the physical differences of the measurers are actually very complex. Therefore, in this study, the correlation between PTT, SBP, and DBP was analyzed, and it was designed to use PPG sensors for device miniaturization. The blood pressure estimation algorithm took into account differences in PPG, heart rate, and personal variables.

Use of Portable Global Positioning System (GPS) Devices in Exposure Analysis for Time-location Measurement

  • Lee, Ki-Young;Kim, Joung-Yoon;Putti, Kiran;Bennett, Deborah H.;Cassady, Diana;Hertz-Picciotto, Irva
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.461-467
    • /
    • 2009
  • Exposure analysis is a critical component of determining the health impact of pollutants. Global positioning systems (GPS) could be useful in developing time-location information for use in exposure analysis. This study compares four low cost GPS receivers with data logging capability (Garmin 60, Garmin Forerunner 201, GeoStats GeoLogger and Skytrx minitracker MT4100) in terms of accuracy, precision, and ease of use. The accuracy of the devices was determined at two known National Geodetic Survey points. The coordinates logged by the devices were compared when the devices were carried while walking and driving. The Garmin 60 showed better accuracy and precision than the GeoLogger when they were placed at the geodetic points. The Forerunner and Skytrx did not record when they were kept stationary. When the subject wore the devices while walking, the location of the devices differed by about 8 m on average between any two device combinations involving the four devices. The distance between the coordinates logged by the devices decreased when the devices were carried with their antennas facing the sky. All the devices showed similar routes when they were used in a car. All the devices except the Forerunner had satisfactory signal reception when they were worn and when they were carried in the car. The GeoLogger is less comfortable for the subject because of specific wearing requirements. This evaluation found that the Garmin 60 and the Skytrx may be useful in personal exposure analysis studies to record time-location data.

Design of Home&Mobile Healthcare System Based on Smart Phone PMG(personal mobile gateway) (스마트폰 PMG(personal mobile gateway) 기반의 홈&모바일 헬스케어 시스템 설계)

  • Jean, Jae-Hwan;Kim, Sung-Hyun;Gang, Seong-In;Kim, Kwan-Hyung;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.757-759
    • /
    • 2011
  • 본 논문에서는 홈 헬스케어에서 건강측정을 위하여 가장 많이 사용되는 개인 건강 기기(personal health device)인 혈당계, 혈압계, 심박측정계(heart rate monitor), 산소포화도 측정계(pulse-oximeter), 심전도 측정계(ECG monitor)의 5가지 홈 헬스케어 의료기기를 구성하고 표준 핵심 기술 요소인 ISO/IEEE 11073, HL7을 준용하는 게이트웨이 플랫폼을 스마트폰에 적용하여 기존의 홈 헬스케어 시스템을 구성하는 단말기 형태의 게이트웨이나 홈 서버 하드웨어 구성을 필요로 하지 않으면서 집안의 고정된 게이트웨이로 인해서 생기는 위치종속성 문제를 해결할 수 있는 PMG(personal mobile gateway) 기반의 홈&모바일 헬스케어 시스템을 개발하고자 한다.

  • PDF

The Study on Concentration of PM10 and Heavy Metal in Public Schools at Chung-Nam Area (충남 지역 일부 학교의 PM10과 중금속 농도에 관한 연구)

  • Son, Bu-Soon;Song, Mi-Ra;Kim, Jung-Duk;Cho, Tae-Jin;Yang, Won-Ho;Chung, Tae-Woong
    • Journal of Environmental Science International
    • /
    • v.17 no.9
    • /
    • pp.1005-1013
    • /
    • 2008
  • In this study, in order to analyze the air quality of the indoor environments of schools, we measured the indoor, outdoor and personal exposure concentration level of $PM_{10}$ for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003. 1. Old classrooms contained more dust than new classrooms; the average of respirable dust is $43.27\;{\mu}g/m^3$ for new classrooms while $53.38\;{\mu}g/m^3$ for old one. The exposure concentration level of respirable dust in new classrooms were in summer higher outdoors than indoors. The values were indoors $46.71\;{\mu}g/m^3$, outdoors $50.46\;{\mu}g/m^3$, and personal $41.62\;{\mu}g/m^3$. Meanwhile in winter indoors had a higher concentration level than outdoors, the values being indoors $39.11\;{\mu}g/m^3$, outdoors $34.86\;{\mu}g/m^3$, and personal $49.01\;{\mu}g/m^3$. 2. Cr concentration level within dust was slightly higher in summer indoors ($101.50{\pm}32.10\;ng/m^3$) and outdoors ($100.89{\pm}35.18\;ng/m^3$) than winter indoors ($85.80{\pm}48.95\;ng/m^3$) and outdoors ($74.43{\pm}38.93\;ng/m^3$), but in personal concentration level, winter was higher. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. As such, a logical and systematic education program for students about the importance of indoor air quality should be carried out. Also the results of $PM_{10}$ concentration level measurements emphasize the need for regular measurements of indoor / outdoor and personal concentration level. New classrooms in particular needs to be used after measuring pollutants and safety, and requires installation of a ventilation device in all classrooms to improve air quality.

Design of Real-time Vital-Sign Encryption Module for Wearable Personal Healthcare Device (착용형 개인 건강관리 장치를 위한 실시간 생체신호 암호화 모듈의 설계)

  • Kim, Jungchae;Yoo, Sun Kook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.221-231
    • /
    • 2013
  • Exchanging personal health information(PHI) is an essential process of healthcare services using information and communication technology. But the process have the inherent risk of information disclosure, so the PHI should be protected to ensure the reliability of healthcare services. In this paper, we designed encryption module for wearable personal health devices(PHD). A main goal is to guarantee that the real-time encoded and transmitted PHI cannot be allowed to be read, revised and utilized without user's permission. To achieve this, encryption algorithms as DES and 3DES were implemented in modules operating in Telos Rev B(16bit RISC, 8Mhz). And the experiments were performed in order to evaluate the performance of encryption and decryption using vital-sign measured by PHD. As experimental results, an block encryption was measured the followings: DES required 1.802 ms and 3DES required 6.683 ms. Also, we verified the interoperability among heterogeneous devices by testing that the encrypted data in Telos could be decoded in other machines without errors. In conclusion, the encryption module is the method that a PHD user is given the powerful right to decide for authority of accessing his PHI, so it is expected to contribute the trusted healthcare service distribution.

Personal Health Record System for Efficient Monitoring of Cancer Therapy (효과적인 암환자 관리를 위한 개인건강기록 관리 시스템)

  • Song, Je-Min;Seo, Sung-Bo;Shin, Moon-Sun;Han, Hye-Sook;Park, Jeong-Seok;Ryu, Keun-Ho
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.65-72
    • /
    • 2016
  • Personal Health Record(PHR) service can be helpful to patients with diseases requiring strict everyday care and medical treatment, such as diabetes or cancer. In this paper, we propose a PHR system specialized in collecting and analyzing health record data of cancer patients, and present the process of how the system can improve the efficiency of cancer treatment process. Through the smart device application, cancer PHR system obtains daily PHR data which is highly related and critical to cancer therapy. The analysis report is provided to the medical staff with an available format suited for Electronic Medical Record used at medical institution. With the final result of PHR analysis which is easily merged with medical chart, most efficient Chemotherapy treatment can be provided for the patients. Also it is possible for the patients to give the information of side-effect and other pain experience during therapy to their doctors without loss of information. The proposed PHR system has the effect of improving the quality of patient care by allowing the medical staff to acquire the main objective data necessary for drug prescription and medical care benefits.

BIOFIT - Smart, Portable, Wearable and Wireless Digital Exercise Trainer Device with Biofeedback Capability

  • Diwakar Praveen Kumar;Oh Young-Keun;Chung Gyo-Bum;Park Seung-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.36-45
    • /
    • 2007
  • Today Human Personal Trainers are becoming very famous in this health conscious world. They teach user to achieve fitness goals in managed way. Due to their high fee and tight schedule they are unavailable to mass number of people. Another solution to this problem is to develop digital personal trainer portable instrument that may replace human personal trainers. We developed a portable digital exercise trainer device - BIOFIT that manages, monitors and records the user's physical status and workout during exercise session. It guides the user to exercise efficiently for specific fitness goal. It keeps the full exercise program i.e. exercises start date and time, duration, mode, control parameter, intensity in its memory which helps the user in managing his exercise. Exercise program can be downloaded from the internet. During exercise it continuously monitors the user's physiological parameters: heart rate, number of steps walked, and energy consumed. If these parameters do not range within prescribed target zone, the BIOFIT will alarm the user as a feedback to control exercise. The BIOFIT displays these parameters on graphic LCD. During exercise it continuously records the heart rate and number of steps walked every 10 seconds along with exercise date and time. This stored information can be used as treatment for the user by an exercise expert. Real-time ECG monitoring can be viewed wirelessly (RF Communication) on a remote PC.

A Study on the Factors Affecting the Purchase of Healthcare Smart Bands (헬스 케어 스마트 밴드 구매에 영향을 미치는 요인에 관한 연구)

  • Choi, Seong-Hun;Kim, Seung-In
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.7
    • /
    • pp.175-181
    • /
    • 2017
  • The purpose of this study is to investigate what factors buyers buy in smart band purchasing. Especially, The study was conducted the perception of smart bands, focusing on personal healthcare, which is one of the biggest concern of today's people, and investigating the needs of users. SmartBand is the product with the highest market share in the wearable device market. It is an indicator of how much modern people are interested in their healthcare. Therefore, this study investigates non-users who are not currently using smart bands, and what factors to consider when buying smart bands. As a result, it was found that the design of the product and the hardware performance are more important than the smart band's personal health care function in purchasing the smart band, and fundamentally, the smart band itself was not needed. Especially, people aged 20-30 years have been burdened with using smart bands continuously.

Design of a Data Grid Model between TOS and HL7 FHIR Service for the Retrieval of Personalized Health Resources (개인화된 건강 자원 조회를 위한 TOS 와 HL7 FHIR 서비스간의 데이터그리드 모델 설계)

  • Jeon, Young-Jun;Im, Seok-Jin;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.139-145
    • /
    • 2016
  • On the ICT healing platform designed to issue early disease alerts, TOS connected between the provider of personal health-related data and the service provider and relayed personalized health data. In the previous study, TOS proposed how to monitor the retrieval and management of document/measurement resources by taking mobile devices into account. Recently the healthcare field, however, defined the standard items needed for communication and data exchanges with a mobile device through HL7 FHIR. This study designed a data grid model between TOS and FHIR to provide personal health resources relayed through TOS in FHIR bundle search sets. The proposed design was organized as follows: first, it stated similarities between the method of TOS resource request and that of FHIR observation request. Then, it designed an eventbus module to process a retrieval request for FHIR service based on the imdb and cluster technologies. The proposed design can be used to expand the old service terminals of ICT healing platform to mobile health devices capable of using FHIR resources.

Asymmetrical Hearing Loss and Related Factors Among the Noise Exposed Male Workers (소음 노출 남성근로자에서 청력 역치의 비대칭성과 관련요인)

  • Lee, Nam-Soo;Lee, Kyung-Jae;Kim, Joo-Ja
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.2
    • /
    • pp.94-101
    • /
    • 2010
  • This study was performed to examine the asymmetry of hearing loss among the noise exposed male workers. Findings of otoscopic examination, pure tone audiometry and tympanometry were evaluated for 179 male workers working in the noise exposed workplace. And also selfadministered structured questionnaires were used for each worker's work-related and general characteristics including personal health behaviors. There were significant differences of hearing threshold between right and left ears at 1,000 Hz and 3,000 Hz(p<0.05). And also significant differences of hearing threshold were noted in the age group over 50 at 3,000 Hz, the high risk drinking group either at 3,000 Hz and 4,000 Hz, the work duration group 10-19 years at 3,000 Hz, the noise exposure group under 90 dB(A) at 3,000 Hz, the noise exposure group over 90 dB(A) at 1,000 Hz, the non-wearing protective device group at 4,000 Hz, and the wearing protective device group at 3,000 Hz(p<0.05). Further study is needed to explore the extent and the related factors of the asymmetry of hearing loss in the general population and occupationally noise exposed group.