• Title/Summary/Keyword: Permissible criteria

Search Result 40, Processing Time 0.024 seconds

A simulation study on predicting the current collection performance in 400km/h on establishing the maximum speed test plan of the next Korean high speed train development project (차세대 고속철도의 최고속도 시험 계획 수립을 위한 집전 성능 예측 시뮬레이션)

  • Kwon, Sam-Young;Park, Chun-Soo;Cho, Yong-Hyeon;Lee, Ki-Won;Park, Young
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.428-432
    • /
    • 2008
  • The next Korean high speed train development project is started. In testing stage of this project, the 400km/h maximum speed test will be conducted. In Korean railway infrastructure conditions the 400km/h seems to be a critical speed especially in the aspect of the overhead contact lines. The current collection performance of the 400km/h which is predicted by dynamic interaction simulation are described in this paper. To discuss the permissible criteria of contact forces, displacements and percentage contact loss, the French 575km/h current collection conditions are simulated. Furthermore, review of the simulation results of the Korean 400km/h current collection conditions is conducted through comparison with that of the French 575km/h.

  • PDF

Implementation of Optimization of the Uplift Amount Measurement System of Overhead Contact Line (전차선 압상량 검출을 위한 최적 시스템 구현)

  • Park, Young;Lee, Kiwon;Park, Chulmin;Kwon, Sam-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.886-890
    • /
    • 2013
  • Uplift of contact wire and dynamic characteristics between pantograph and contact wire are key interaction performance of OCS (Overhead Catenary System). These two evaluation items are the approval criteria for the performance between OCS and pantograph. A telemetry system or DAQ (Data Acquisition) System based on wireless communication make it monitor a dynamic behavior which is measured directly in a 25 kv like parts. While permissible working time is too short time to install is too long. In this paper, it is described that optimization the telemetry measurement system for OCS and increasing accuracy, easy adaptation, and faster handling can be also achieved through the study.

Storage Capacity Estimation for Automated Storage/Retrieval Systems under Stochastic Demand (확률적 수요하에서의 자동창고의 필요 저장능력 추정)

  • Cho, Myeon-Sig;Bozer, Yavuz-A.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.27 no.2
    • /
    • pp.169-175
    • /
    • 2001
  • Most of studies on automated storage/retrieval (AS/R) system assumed that storage capacity is given, although it is a very important decision variable in the design phase. We propose a simple algorithm to estimate the required storage capacity, i.e., number of aisles and number of openings in vertical and horizontal directions in each aisle, of an AS/R system under stochastic demand, in which storage requests occur endogenously and exogenously while the retrieval requests occur endogenously from the machines. Two design criteria, maximum permissible overflow probability and maximum allowable storage/retrieval (S/R) machine utilization, are used to compute the storage capacity. This model can be effectively used in the design phase of new AS/R systems.

  • PDF

Storage Capacity Estimation for Automated Storage/Retrieval Systems Considering Material Handling Delay (자재취급 지연을 고려한 자동창고의 저장능력 추정)

  • 조면식
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.3
    • /
    • pp.71-82
    • /
    • 2001
  • Considering material handling delay which occurs between storage and processing stations, we propose an algorithm to estimate the required storage capacity, i.e., number of aisles and number of openings in vertical and horizontal directions in each aisle, of an automated storage/retrieval(AS/R) system. Due to the random nature of storage and retrieval requests, proportion of single and dual commands is not known in advance. Two design criteria, maximum permissible overflow probability and maximum allowable storage/retrieval(S/R) machine utilization, are used to compute the storage capacity. Most of studies assume that storage capacity of AS/R systems is given, although it is a very important decision variable in the design phase. Therefore, the proposed model can be effectively used in the design phase of new AS/R systems.

  • PDF

Thermal Model Correlation and Heater Design Verification for LEO Satellite Optical Payload's Thermal Analysis Model Verification (저궤도 위성 광학탑재체의 열해석 모델 검증을 위한 열모델 보정 및 히터 설계)

  • Kim, Min-Jae;Huh, Hwan-Il;Kim, Sang-Ho;Chang, Su-Young;Lee, Deog-Gyu;Lee, Seung-Hoon;Choi, Hae-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.11
    • /
    • pp.1069-1076
    • /
    • 2011
  • All of the satellite components must be operated within the permissible temperature range during the mission in orbit. Therefore, thermal design is performed to develop verified thermal model and to secure thermal stability on the ground. In this study, thermal model correlation was performed to satisfy the criteria of correlation using ground thermal vacuum/thermal balance test results of LEO satellite optical payload. We also secured verified thermal model by controlling operating cycle of flight heaters. In addition, it was confirmed that all components are within the permissible temperature range through conducting orbit environment thermal analysis. We also secured thermal stability of the satellite.

Monitoring of Sodium Content in Commercial Baechu (Kimchi Cabbage) Kimchi (시판 배추김치의 나트륨 함량 모니터링)

  • Eun Woo, Moon;Hee-Min, Lee;Sung Hyun, Kim;Hye-Young, Seo
    • The Korean Journal of Food And Nutrition
    • /
    • v.35 no.6
    • /
    • pp.537-542
    • /
    • 2022
  • This study was conducted to provide basic data on the amount of sodium and the setting of permissible error range of actual measurement, which is a problem for cabbage kimchi nutrients subject to labeling. The sample targeted was baechu (Kimchi cabbage) kimchi, which might have a large variation in sodium content by part of kimchi. Kimchi samples were collected twice from eight companies by season (spring, summer, fall, and winter). The average sodium content in kimchi samples was 619±87 mg/100 g (range, 534±63 mg/100 g to 783±40 mg/100 g). The error in average annual sodium content of abandonment kimchi (maximum value difference compared to the minimum value) was 26.8 to 64.3%. Sodium contents in kimchi produced in spring and summer were relatively low. However, deviation between individuals was large. It was found that cases exceeding the permissible error (120%) standard varied depending on the criteria for setting the amount of sodium. In addition, due to seasonal differences, sodium content in kimchi exceeded 120% of the labeling value. Thus, it is necessary to set standards suitable for characteristics of kimchi to prevent unintentional violations of labeling standards by raw materials and manufacturing processes.

A study on the effects of changes in the estimating criteria for ventilation requirements in road tunnels (도로터널 소요환기량 산정기준 변화에 따른 영향 분석)

  • Kim, Hyo-Gyu;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.779-793
    • /
    • 2019
  • The ventilation rate (Qreq) requirement in road tunnels is not just a basic information for determining the tunnel cross-sectional area, but also a major factor for the ventilation system selection. The Qreq is predominantly dependent on the vehicle traffic volume, while among others, the vehicle exhaust emissions and permissible standards are critical. This paper analyzes the changes in the Qreq designing criteria and/or recommendations suggested by World Road Association and local authorities over the last 20 years, since the first local designing criteria was established in 1997 by Korea Expressway Corporation. Additionally, based on the updated vehicle emission standards of Ministry of Environment and recent recommendations of the World Road Association (WRA), changes in the Qreq and its effects are studied in terms of the length and grade of the tunnel.

An Improved Handover Method Using Mobile Tracking by Fuzzy Multi-Criteria Decision Making (기준 의사 결정에 의한 모바일 트래킹을 이용한 향상된 핸드오버)

  • Kang, Il-Ko;Shin, Seong-Yoon;Lee, Jong-Chan;Pyo, Seong-Bae;Rhee, Yang-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.3
    • /
    • pp.1-10
    • /
    • 2006
  • It is widely accepted that the coverage with high user densities can only be achieved with small cell such as micro- and pico-cell. The smaller cell size causes frequent handovers between cells and a decrease in the permissible handover Processing delay. This may result in the handover failure. in addition to the loss of some Packets during the handover. In these cases. re-transmission is needed in order to compensate errors, which triggers a rapid degradation of throughput. In this paper, we propose a new handover scheme in the next generation mobile communication systems, in which the handover setup process is done in advance before a handover request by predicting the handover cell based on mobile terminal's current position and moving direction. Simulation is focused on the handover failure rate and Packet loss rate. The simulation results show that our proposed method provides a better performance than the conventional method.

  • PDF

Review of Shielding Evaluation Methodology for Facilities Using kV Energy Radiation Generating Devices Based on the NCRP-49 Report

  • Na Hye Kwon;Hye Sung Park;Taehwan Kim;Sang Rok Kim;Kum Bae Kim;Jin Sung Kim;Sang Hyoun Choi;Dong Wook Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.53-62
    • /
    • 2022
  • In this study, we have investigated the shielding evaluation methodology for facilities using kV energy generators. We have collected and analysis of safety evaluation criteria and methodology for overseas facilities using radiation generators. And we investigated the current status of shielding evaluation of domestic industrial radiation generators. According to the statistical data from the Radiation Safety Information System, as of 2022, a total of 7,679 organizations are using radiation generating devices. Among them, 6,299 facilities use these devices for industrial purposes, which accounts for a considerable portion of radiation. The organizations that use these devices evaluate whether the exposure dose for workers and frequent visitors is suitable as per the limit regulated by the Nuclear Safety Act. Moreover, during this process, the safety shields are evaluated at the facilities that use the radiation generating devices. However, the facilities that use radiating devices having energy less than or equal to 6 MV for industrial purposes are still mostly evaluated and analyzed according to the National Council on Radiation Protection and Measurements 49 (NCRP 49) report published in 1976. We have investigated the technical standards of safety management, including the maximum permissible dose and parameters assessment criteria for facilities using radiation generating devices, based on the NCRP 49 and the American National Standards Institute/Health Physics Society N.43.3 reports, which are the representative reports related to radiation shielding management cases overseas.

Study on Compatibility Analysis between Radio Services (무선통신 업무간 양립성 분석에 관한 연구)

  • Kang, Jeong-Yong;Kim, Jin-Young;Kim, Eun-Cheol;Kim, Jong-Heon;Ryu, Chung-Sang;Oh, Seong-Taek
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.3
    • /
    • pp.122-137
    • /
    • 2007
  • In this paper, compatibility between different radio services or systems is analyzed when they are in adjacent band or co-channel. The first step of the compatibility analysis is establishing an interference scenario. And an interference pobability from an interfering transmitter to a victim receiver is calculated by means of Monte-Carlo simulation techniques. Then the calculated result is compared with the predefined interference criteria, maximum permissible interference probability and we can determine compatibility in accordance with the active interferer density, channel bandwidth, cell radius, distance between interfering transmitter and victim receiver, and duty cycle. It is assumed that Propagation modes are the free space model and extened Hata model.

  • PDF