• Title/Summary/Keyword: Permeation test

Search Result 196, Processing Time 0.028 seconds

A Permeation Characteristics Study of Water- or Oil-soluble Substances through Condition Setting for the In Vitro Skin Absorption Method (피부흡수 대체시험법의 조건설정을 통한 수용성, 지용성 물질의 투과 특성 연구)

  • Seo, Ji-Eun;Lee, Jinho;Kim, Bae-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.1
    • /
    • pp.77-86
    • /
    • 2017
  • Objectives: The purpose of this study was to compare permeation characteristics in three skin types using oil-soluble benzoic acid and water-soluble caffeine after method condition optimization based on OECD guideline 428. Methods: A Franz diffusion cell, a reliable alternative method for skin permeation, was used. One-milliliter samples were taken and immediately replaced with fresh solution in the receptor chamber at regular time intervals (1, 2, 4, 7, 10 and 24 hr). The amount of test substances was measured by LC-MS/MS. Results: The permeation rate increased dose-dependently, and the permeation orders were $KeraSkin^{TM}$ > hairless mouse full skin > human cadaver epidermis for skin types, and benzoic acid solution > caffeine solution > benzoic acid cream > caffeine cream for type of test materials. Conclusion: According to the definitions of Marzulli, benzoic acid and caffeine would be classified as 'fast' and 'moderate' compared with the permeation of other chemical species. The setting conditions and permeation characteristics performed in this study are expected to contribute to future permeation studies.

Separation of $CO_2$ and $N_2$ with a NaY Zeolite Membrane under Various Permeation Test Conditions

  • Cho, Churl-Hee;Yeo, Jeong-Gu;Ahn, Young-Soo;Han, Moon-Hee;Hyun, Sang-Hoon
    • Korean Membrane Journal
    • /
    • v.8 no.1
    • /
    • pp.21-30
    • /
    • 2006
  • A faujasite NaY zeolite membrane was prepared on a tubular ${\alpha}-Al_2O_3$ support by the secondary growth process, and effects of permeation test conditions on the $CO_2/N_2$ separation were investigated. A NaY zeolite membrane with good $CO_2/N_2$ separation was successfully synthesized by using the hydrothermal solution ($Al_2O_3:SiO_2:Na_2O:H_2O$ = 1:6:14:840 in a molar base): at a permeation temperature of $30^{\circ}C$, its $CO_2$ permeance and $CO_2/N_2$ separation factor were $2.5{\times}10^{-7}mol/m^2secPa$ and 34, respectively. The $CO_2$ and $N_2$ permeations were highly dependent on permeation test conditions (feed composition, feeding rate, feed pressure, He sweeping rate and permeation temperature). The results indicated that (i) $CO_2$ and $N_2$ permeations through NaY zeolite membrane are governed by surface and micropore diffusions, respectively, (ii) the preparation of NaY zeolite membrane with a large permeating area is one of the most difficult hurdles for its real applications, and (iii) the retardation of $N_2$ permeation is an effective key to improve $CO_2/N_2$ separation factor in NaY zeolite membrane.

Establishment of a Release Test Reflecting in vitro Skin Permeation of Nicotine from Commercial Patches (니코틴 패취제로부터 니코틴의 피부투과를 반영하는 방출시험법의 설정)

  • Lee, Su-Jung;Kim, Jae-Keun;Yun, Mi-Ok;Kim, Ho-Jeong;Shim, Chang-Koo;Ze, Keum-Ryon
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.1
    • /
    • pp.27-32
    • /
    • 2000
  • Various release test methods have been applied for the evaluation of nicotine release in vitro from commercial patches. However, whether and how the release data reflect the permeation of nicotine across the skin, is not fully elucidated. To predict in vivo bioavailability from in vitro release tests, correlation between in vitro release and in vitro skin permeation was assessed in the present study. Release of nicotine from three commercial patches was measured for 24 hours under nine experimental conditions which were classified depending on the apparatus (i.e., paddle over disk, cylinder and reciprocating holder) and dissolution media (i.e., phosphate buffer pH 7.4, water and the 1 % phosphoric acid pH 1.5). In vitro permeation of nicotine from the patches across the human cadaver skin was also measured using a diffusion cell. The release of nicotine was better explained by the Higuchi's equation rather than by the first order rate equation. Correlation between the release rate and the in vitro skin permeation differed among the patches. However, in general, the cylinder method, in which water is used as a dissolution medium, showed the highest correlation among the nine release test conditions.

  • PDF

Skin Permeation Characteristics of Estradiol Patches and Their Comparative Efficacy Test in Ovariectomized Rabbits (에스트라디올 패취의 피부투과 특성 및 난소제거 토끼에서의 비교 효력시험)

  • Ryoo, Je-Phil;Choi, Mi-Suk;Choi, Jong-Kun;Kim, Soo-Hyeon;Kim, Eung-Goo;Yoon, Byung-Il
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.1
    • /
    • pp.47-54
    • /
    • 1995
  • Transdermal patch formulations of estradiol to treat post-menopausal symptoms and prevent osteoporosis in women were developed and evaluated for the permeation characteristics through the excised hairless mouse abdorminal skin and the uterotropic effect on the ovariectomized rabbits. The design of patch formulations was optimized by varying several formulation parameters, such as type of enhancers, amount of enhancers, amount of drug loading and coating thickness. Compared to a commercially available transdermal product, several patch formulations showed the similar skin permeation profiles (following zero-order kinetics), but their skin permeation rates were lasted for the longer period (a week). In one-week uterotropic efficacy test in the ovariectimized rabbits, the selected patch formulations showed the positive effect in atrophy of the urogenital epithelium. The mean values of uterus weight in rabbits after application of patches containing estradiol were much higher than those in control group (containing no drug).

  • PDF

Mechanistic Studies on the Hydrogen Evolution and Permeation of Ultra-Strong Automotive Steel in Neutral Chloride Environments (중성의 염화물 환경 내 자동차용 초고강도강의 부식반응에 기인한 수소원자의 발생 및 투과 메커니즘)

  • Hwang, Eun Hye;Ryu, Seung Min;Kim, Sung Jin
    • Korean Journal of Materials Research
    • /
    • v.28 no.7
    • /
    • pp.428-434
    • /
    • 2018
  • Hydrogen evolution on a steel surface and subsequent hydrogen diffusion into the steel matrix are evaluated using an electrochemical permeation test with no applied cathodic current on the hydrogen charging side. In particular, cyclic operation in the permeation test is also conducted to clarify the corrosion-induced hydrogen evolution behavior. In contrast to the conventional perception that the cathodic reduction reaction on the steel in neutral aqueous environments is an oxygen reduction reaction, this study demonstrates that atomic hydrogen may be generated on the steel surface by the corrosion reaction, even in a neutral environment. Although a much lower permeation current density and significant slower diffusion kinetics of hydrogen are observed compared to the results measured in acidic environments, they contribute to the increase in the embrittlement index. This study suggests that the research on hydrogen embrittlement in ultra-strong steels should be approached from the viewpoint of corrosion reactions on the steel surface and subsequent hydrogen evolution/diffusion behavior.

A Study on Performance of Protective Gloves to Isocyanate Toxicity (이소시안화물 독성에 대한 보호장갑의 성능 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.62-69
    • /
    • 2008
  • As the concerns of dermal exposure of spray painters to isocyanates in the automobile industry, glove performance was examined like permeation rate and breakthrough time including fatigue test. Methylene chloride was used as the solvent for derivatization of the isocyanates with a 97.5% recovery. Ghost wipe pads were used to wipe the surface of the glove material after chemical penetration through the glove material placed under a disposable test cell. Several solvents were tested, such as thinner(xylene, toluene) and cleaning agent(acetone) by using a standard permeation test cell(AS/NZS standard 2161. part 10.3). Solvents accelerate chemical permeation through the gloves more quickly than pure HDI hardener products. The longest breakthrough times were from Nitrosolve gloves, not detected in 8 hours, compared with others like Latex, Neoprene, TNT and Dermo Plus. Therefore Nitrosolve gloves could be recommended as personal protective equipment in crash repair shops. In addition, revised exposure limit of korean regulation should be suggested for employee to minimize the risk of health symptoms.

Permeation Properties of Surface Modified Nanofiltration Membrane (표면 개질된 나노복합막의 투과 특성)

  • Tak Tae-Moon;Park Hyung-Kiu;Jang Gyung-Gug
    • Membrane Journal
    • /
    • v.14 no.3
    • /
    • pp.207-217
    • /
    • 2004
  • In this study, we prepared nanofiltration membrane by applying the interfacial polymerization method as a way of manufacturing composite membranes. We have examined the effects of various preparation factors such as monomer concentration and composition, thermal curing condition, post treatment condition. In addition to preparation conditions, we also monitored the effects of operation conditions such as feed solution concentration and operation pressure on the permeation properties of the resulting nanofiltration membrane. We intended to increase the permeation rate of nanofiltration membrane by the enlargement of effective surface area using additives during interfacial polymerization step. With increasing the monomer concentration, membrane permeation rate are decreased with maintaining almost constant rejection. With respect to curing condition, with increasing the curing temperature both permeation rate and rejection are decreased. With increasing the ratio of MPD in amino monomer composition, permeation rate decreased drastically with high rejection. With increasing the feed solution concentration, both permeation rate and rejection decreased. Both permeation rates and rejection increased with increasing the operating pressure. Nanofiltration membrane have higher surface roughness with increasing additive concentration in the case of using MPD contained amine composition than using piperazine alone. Permeation rates are much lower than the nanofiltration membrane prepared by piperazine.

Analysis of Injection Efficiency for Cement Grouts by Model Test of Permeation in Soil (지반침투모형시험에 의한 시멘트그라우트의 주입성능 분석)

  • Song, Young-Su;Lim, Heui-Dae;Choi, Dong-Nam
    • Economic and Environmental Geology
    • /
    • v.43 no.2
    • /
    • pp.177-184
    • /
    • 2010
  • When cement grout is used for waterproofing of grounds, important roles are played by fluidity, particle size and bleeding. The most important element which determines their characteristics is the water/cement ratio of grout. Moreover in order to improve the efficiency of soil permeation, micro cement with a smaller average diameter is used in addition to ordinary portland cement. Besides the mixing ratio and cement diameter, the condition of ground is also of fundamental importance in the efficiency of permeation. In order to evaluate grout in terms of permeation ability into ground, we need a field test of grounting, which is cost and time consuming. In this paper we present a laboratory test method in which the suitability and efficiency of grouts are simply and more practically tested. In Korea neither a test standard nor devices are available to simulate grouting in a laboratory. We devised a grout injection equipment in which grouting was reproduced in the same condition with different materials, and suggested a standard for the production of specimens. Our tests revealed that the efficiency of injection increases with the water/cement ratio. We also found that more efficiently injected is the grout with the order of decreasing size; MS8000, micro cement, and ultra fine cements, and colloidal super cement.

Transdermal Permeation-enhancing Activities of some Inorganic Anions

  • Ko, Young-Il;Kim, Sung-Su;Han, Suk-Kyu
    • Archives of Pharmacal Research
    • /
    • v.18 no.4
    • /
    • pp.231-236
    • /
    • 1995
  • Effects of sodium salts of various monovalent inorganic anions on transdermal permeation of salicylic acid were investigated. In in-vitro experiment using a Franz-type diffusion cell and excisicylic acid were investigated. In-vitro experiment using a Franze-type diffusion cell and excised mouse skin, the permeation-enhancing activities of the sodium salts of inoraganic anions were rougly proportional to lyotropic Hofmeister serlling abilities of the anions l F/sup -/

  • PDF

Evaluation of Durability on MMA-Modified Polymer Paste for Coating materials (코팅재로서 MMA 개질 폴리머 페이스트의 내구성능 평가)

  • Yeon, Kyu-Seok;Lee, Hyun-Jong;Joo, Myung-Ki;Jin, Xing-Qi;Lee, Chi-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.807-810
    • /
    • 2005
  • In this study, MMA-modified paste of coating material for protecting the concrete structures was developed. The coating material was applied to cement concrete specimens by brush, roller and spray in each of which one, two and three layers to survey, by the cold-hot iterative test, the neutralization test, the chloride ion permeation test and the ante-abrasion test, the affect of painting methods and layers influencing on the durability of coating material. Results of the cold-hot iterative test showed that, regardless of the painting methods and layers, the defects such as crack or fuzz on surface were not produced. As the number of painting layers increased, the neutralization prevention as well as the chloride ion permeation prevention effects were increased. On the other hand, no difference was found between the painting methods. Reducing weight by abrasion of polymer paste coating material was $20\%$ comparing to that of cement mortar.

  • PDF