• Title/Summary/Keyword: Permanent Magnets

Search Result 497, Processing Time 0.026 seconds

Magnetic Properties of NdFeB Permanent Magnets Fabricated by CAPA Process with Melt-spun Powder (급냉응고된 분말로부터 CAPA법으로 제조한 NdFeB 영구자석의 자기적 특성)

  • 김윤배;김형태;전우용;김학신
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.6
    • /
    • pp.250-255
    • /
    • 2001
  • Magnetic properties of the isotropic and anisotropic NdFeB magnets obtained by the Current-Applied Pressure-Assisted (CAPA) process from a melt-spun NdFeB powder were investigated using B-H loop analyser. The coercivity of the isotropic magnets is sensitive to the applied pressure in the CA-pressing and increases with increasing the pressure. The remanence of the anisotropic magnet increases with increasing the degree of deformation, and it results in the increase of a maximum energy Product. The best magnetic Properies of the isotropic and anistropic magnet are B$\sub$r/= 8.7 kG, $\sub$i/H$\sub$c/= 16.9 kOe, (BH)$\sub$max/= 16.5 and B$\sub$r/= 13.6 kG, $\sub$i/H$\sub$c/= 10.9 kOe, (BH)$\sub$max/= 44.2 MGOe, respectively.

  • PDF

Experimental Study for Dynamic Characteristics of Eddy Current Shock Absorber (와전류 충격완충장치의 실험적 동특성 연구)

  • Kwag, Dong-Gi;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.12
    • /
    • pp.1089-1094
    • /
    • 2007
  • This paper is concerned with a new concept for the damper without neither a coil spring nor fluid. The new damper concept consists of the permanent magnets and the cylinder of the conducting material. The opposite pole magnets produces the repulsive forces and this is substituted for the coil spring. The relative motion between the magnets and conducting cylinder produces eddy currents thus resulting in the electromagnetic force, which turns out to be the damping force and is substituted for a damping fluid. This damper is called the eddy current damper(ECD). The important advantage of the proposed ECD is that it does not require any damping fluid and any external power and is non-contacting and relatively insensitive to temperature. In the present study, the proposed ECD was constructed and the experiments were performed to investigate its dynamic characteristics. The experiments shows that the proposed ECD has the excellent damping ability.

Elementary Students' Conceptions of Magnetic Field by Drawing lines of Magnetic Field (자기력선 그림을 통한 초등학생들의 자기장 개념 조사)

  • Kwon, Sung-Gi;Shin, Mi-Sung
    • Journal of Korean Elementary Science Education
    • /
    • v.26 no.4
    • /
    • pp.440-448
    • /
    • 2007
  • The purpose of this study is to examine elementary students' conceptions of magnetic fields around various magnets by drawing tasks. A total of 105 elementary students from the 3rd and 6th grade levels were asked to draw how iron filings would arrange around magnets. We classified their drawings of magnetic field lines with some criteria to identify conceptions of magnetic forces and checked them through interviewing about their representative drawing. Through analyzing drawings, we discovered that 40% of elementary students drew the correct arrangement of iron filings around a bar magnet. In the case of two bar magnets in opposite directions, 33% of them drew correct patterns of iron dust and around two magnets in the same direction only 20% did well. Only 2.9% and 7.6% of students presented the correct drawings of magnetic fields near a disc and a horseshoe magnet. While 3rd grade students were supposed to be poor in drawings of magnetic fields around a loose and a dense coil which was not learned about, only 31% and 23% of 6th grade students who have just studied electromagnetism properly drew patterns of iron dust. This shows that only one quarter of students understood the magnetic filed lines even after instruction of electromagnetism. Many of 6th grade students learned a solenoid becomes just as a permanent magnet, but very few of them correctly drew a magnetic field line could distinguish between the iron dust around a loose and dense coil. After interviewing students, it is found that students consider magnetic forces to be existed only in parts of magnet because many of them drew magnetic field line of a specific areas around magnets. Students had misconceptions that magnetic forces exist only on the poles not in the middle around a horseshoe magnet. Also the disc-shape magnet made students to reveal various types of misconceptions: N- and S-poles are mixed in a whole magnet and right part of a disc-shape magnet is N-pole, left part is S-pole. Students who had not studied magnetic fields of around a magnet and electromagnets could not draw the correct patterns of iron dust suggest that it is indispensable for students to teach how patterns of iron filings would represent a visual image of magnetic fields in order to understand magnetic fields.

  • PDF

Rare Earth Dispute and Trend in Development of NdFeB Anisotropic Bonded Magnets (희토류 자원분쟁과 NdFeB계 이방성 본드자석 개발동향)

  • Kim, H.J.;Kim, S.M.
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.3
    • /
    • pp.109-115
    • /
    • 2012
  • NeFeB anisotropy bonded magnet has proposed a new paradigm of weight reduction of small motors by replacing the conventional ferrite permanent magnets with its high magnetic property of 25 MGOe during last five years. It has also advanced by leaps and bounds in the field of motor industry for automobiles and electric power tools. And it has led a new innovation of fifty percent weight lightening compared to its current motors by correctly focusing on fuel performance improvement through weight lightening that automobile industry chased. There was, however, another price skyrocketing in 2011 after China had announced its export regulation in rare earth materials in July, 2010. And this price change has an extensive impact on the industries that consume rare earth magnets. This environmental change has caused technical challenge to improve the performance by using least amount of rare earth elements in NdFeB anisotropy bonded magnets, and led to make a new technical approach to a new applied field. In this article, we will show how each nation deals with this industrial issue, and introduce development trend and application of anisotropic NdFeB bonded magnets, so-called MAGFINE made by Aichi Steel Corp.

THE EFFECT OF PERMANENT MAGNET CONNECTING WITH DENTAL IMPLANT ON DISTRIBUTION AND ATTACHMENT OF OSTEOBLAST-LIKE CELL AROUND THE DENTAL IMPLANT (임플랜트에 연결한 영구자석이 임플랜트 주위 뼈모세포의 분포와 부착에 미치는 영향에 관한 연구)

  • Oh Na-Hee;Choi Boo-Byung;Kwon Kung-Rock;Baik Jin;Lee Sung-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.511-518
    • /
    • 2005
  • Purpose: The purpose of this study is to find the effect of rare earth magnet's magnetic field of to the osteoblast around the implant by the means of observation number, and distribution around the implant which is connected to the permanent magnet but not, counted and compared by the number of cells attached to the surface of the implant. Material and method: The permanent magnets, made in the healing cap form, were connected to the implant future, and placed on the culture plate, The osteoblast-like cell: MC3T3-E1 were used for cell culture. As the control group, the implant were connected to normal healing cap, and cultured in the same conditions. 48 hours later, using inverted microscope, the number and distribution of osteoblast around the implant were observed, and 72 hours later, the number of the cells attached to the implant were counted. Results: As a result, the implant connected to the permanent magnet had proved to have a more concentrated cell distribution rate than the control group. The implant connected to the permanent magnet, neck area : which has about 10 gauss magnetic force, had more cells than apex area. The implant connected to the permanent magnet had proven to attach to the osteoblast more productively than control group's implant. Conclusions: This research showed that the magnetic field of the permanent magnet affected the distribution and growth rate of the osteoblast around the implant. In order to support this study, it also had need to monitor the progress of the permanent magnet specifically shown on the neck area, which has10 gauss magnetic force. So after additional research on the distribution and attachment of the cells, and further more, on bone formation, it will be concluded that the clinical applications ,such as immediate loading of implant treatment are possible.

Characteristic Analysis for the Reduction Detent Force of Double-sided Slotted Type Permanent Magnet Linear Generator for Wave Energy Conversion (파력에너지 변환용 양측식 슬롯티드 타입 선형 발전기의 디텐트력 저감을 위한 특성해석)

  • Seo, Sung-Won;Choi, Jang-Young;Koo, Min-Mo;Park, Hyung-Il;Hong, Keyyong;Kim, Kyong-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.31-37
    • /
    • 2016
  • This study considered the reduction of the detent force of a permanent magnet linear synchronous generator (PMLSG). The PMLSG has a relatively large magnetic air gap. Thus, a slotted type of stator structure is generally employed. Furthermore, the detent force, which is caused by energy imbalances owing to the interaction between tooth-slot structures and the permanent magnets (PMs), must be minimized for start-up operation. Therefore, in this paper, the methods of auxiliary teeth and a notch in the teeth are applied to reduce the detent force.

Design and Implementation of integrated drive circuit for a small BLDG Motor (드라이브 내장형 소형 BLDC 모터의 설계와 구현)

  • Choi, J.H.;Lee, J.B.;Rhyu, S.H.;Chung, J.K.;Sung, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.170-172
    • /
    • 2003
  • Among low power servo applications, classical DC motors are very popular because they are reasonably cheap and easy to control. The main disadvantage is the mechanical collector which has only a limited life period. Also, brush sparking can destroy the rotor coil, generate EMC problems. So permanent magnet brushless do motors and drives are being used increasingly in a wide range of applications. This has been made possible with the advantages of high performance permanent magnets with high coercively and residual magnetic, which make it possible for the PM to have superior power density, torque to inertia ratio and efficiency, when compared to an induction or conventional dc machine. This paper presents the design of a PM brushless dc motor drive simplistically operates as a classical dc motor. The BLDC motor drive system for this paper composes to the power integrated circuits, the one chip device. And several simple semiconductors add to drive system for a motor drive system simplistically operates as a conventional dc motor. Test results confirmed the feasibility of the proposed motor drive system design.

  • PDF

A Fault Severity Index for Stator Winding Faults Detection in Vector Controlled PM Synchronous Motor

  • Hadef, M.;Djerdir, A.;Ikhlef, N.;Mekideche, M.R.;N'diaye, A. O.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2326-2333
    • /
    • 2015
  • Stator turn faults in permanent magnet synchronous motors (PMSMs) are more dangerous than those in induction motors (IMs) because of the presence of spinning rotor magnets that can be turned off at will. Condition monitoring and fault detection and diagnosis of the PMSM have been receiving a growing amount of attention among scientists and engineers in the past few years. The aim of this study is to propose a new detection technique of stator winding faults in a three-phase PMSM. This technique is based on the image analysis and recognition of the stator current Concordia patterns, and will allow the identification of turn faults in the stator winding as well as its correspondent fault index severity. A test bench of a vector controlled PMSM motor behaviors under short circuited turn in two phases stator windings has been built. Some experimental results of the phase to phase short circuits have been performed for diagnosis purpose.

Investigation of New Ionized Cluster Beam Source (새로운 이온화된 클라스터 빔원의 제작과 특성 조사)

  • ;;;;S.G.Kondrnine;E.A. Krallkina
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.3
    • /
    • pp.251-257
    • /
    • 1996
  • The present paper represents the results of development and first experimental tests of a new ionized cluster beam (ICB) source. The novelty of ICB source lies in the fact that the crucible and ionization parts are spaced in one cylindrical shell but are not divided in an electric circuit. The ICB source adapts permanent magnets to increase the ionization efficiency. The maximum obtained $Cu^+$ ion current denisity is $1.5{\mu}A/\textrm{cm}^2$, therewith the ionization rate amounts 3% under deposition rate is 0.2$\AA$/s and the acceleration voltage is 4 kV, the $Cu^+$ ion beam uniformity is better than 95%.

  • PDF

Distalization of the lower first molar using Jones Jig (Jones Jig를 이용한 하악 제 1 대구치 원심이동의 치험례)

  • Lee, Sang-Min;Kim, Jong-Bum;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.543-548
    • /
    • 1997
  • The first permanent molar takes important place in the occlusion. Malposition of the lower first molar is frequently due to mesial migration, which is occurred by early exfoliation of the second deciduous molar or proximal caries of deciduous teeth. Above things happen without any consideration of space maintainer, prompt measures for space regaining have to be started. Especially in the case with early loss of the second deciduous molar, it has been said that there is no suitable appliance for maintaining the space before the eruption of the permanent first molar. In distalizing the upper first molar, headgears have been routinely used, which its result was definitely depended on cooperation of the patients. Nowadays, appliances such as pendulum appliances, K-loop, magnets, which can be used without cooperation of the patients, are introduced. Jones Jig, one of the molar distalizing appliances, was used on the patients who visited department of pediatric dentistry in Seoul National University Dental Hospital complaining of no eruption space for the lower second bicuspid. Either removable splint or lingal arch was used as the anchorage. Jones Jig was favorably used in the lower molar, where vestibule is shallow, and this is a case report on the satisfactory result thereof.

  • PDF