Browse > Article
http://dx.doi.org/10.4283/JKMS.2016.26.1.031

Characteristic Analysis for the Reduction Detent Force of Double-sided Slotted Type Permanent Magnet Linear Generator for Wave Energy Conversion  

Seo, Sung-Won (Department of Electrical Engineering, Chungnam National University)
Choi, Jang-Young (Department of Electrical Engineering, Chungnam National University)
Koo, Min-Mo (Department of Electrical Engineering, Chungnam National University)
Park, Hyung-Il (Department of Electrical Engineering, Chungnam National University)
Hong, Keyyong (Offshore Plant Research Division, Korea Research Institute of Ships & Ocean Engineering)
Kim, Kyong-Hwan (Offshore Plant Research Division, Korea Research Institute of Ships & Ocean Engineering)
Abstract
This study considered the reduction of the detent force of a permanent magnet linear synchronous generator (PMLSG). The PMLSG has a relatively large magnetic air gap. Thus, a slotted type of stator structure is generally employed. Furthermore, the detent force, which is caused by energy imbalances owing to the interaction between tooth-slot structures and the permanent magnets (PMs), must be minimized for start-up operation. Therefore, in this paper, the methods of auxiliary teeth and a notch in the teeth are applied to reduce the detent force.
Keywords
permanent magnet linear synchronous generator; detent force; auxiliary teeth; notch;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 A. Hamler and B. Hribernik, IEEE Trans. Magn. 32, 1545 (1996).   DOI
2 Y. U. Park, J. H. Cho, S. H. Rhyu, and D. K. Kim, J. Magn. 18, 114 (2013).
3 J. H. Kim, J. M. Seo, H. K. Jung, and C. Y. Won, J. Magn. 19, 411 (2014).   DOI
4 H. Polinder, F. F. A. van der Pijl, G. J. de Vilder, and P. J. Tavner, IEEE Trans. Energy. Conv. 21, 543 (2006).
5 Y. Amara, J. B. Wang, and D. Howe, IEEE Trans. Energy Conv. 20, 761 (2005).   DOI
6 M. Leijon, H. Bernhoff, O. Agren, J. Isberg, J. Sundberg, M. Berg, K. Karlsson, and A. Wolfbrandt, IEEE Trans. Energy Conv. 20, 219 (2005).   DOI
7 M. Inoue and H. Sato, IEEE Trans, Magn. 36, 1890 (2000).   DOI
8 T. Ishikawa and G. Slemon, IEEE Trans, Magn. 29, 2028 (1993).   DOI
9 Z. Q. Zhu and D. Howe, IEEE Trans Magn. 28, 1371 (1992).   DOI
10 Z. Q. Zhu, Z. P. Xia, D. Howe, and P. H. Mellor, IEE Proc. Elect. Eng. B-144, 227 (1997).
11 D. W. Chung and Y. M. You, J. Magn. 19, 273 (2014).   DOI
12 D. W. Chung and Y. M. You, J. Magn. 20, 176 (2015).   DOI
13 Y. Chen, S. Chen, Z. Q. Zhu, D. Howe, and Y. Y. Ye, IEEE Trans. Magn. 42, 3416 (2006).   DOI
14 C.-L. Chiu, Y.-T. Chen, and W.-S. Jhang, IEEE Trans. Magn. 44, 2317 (2008).   DOI
15 D.-R. Huang, T.-F. Ying, S.-J. Wang, and C.-m. Zhou, IEEE Trans. Magn. 34, 2075 (1998).   DOI
16 D. R. Huang, C. Y. Fan, S. J. Wang, H. P. Pan, T. F. Ying, C. M. Chao, and Eric G. Lean, IEEE Trans. Magn. 35, 839 (1999).   DOI