2차원 자기장에 의한 spin-valve 터널링 자기저항 소자의 자유층 반전 거동에 관한 연구 (Investigation on the Free Layer Switching behavior of a Spin-valve MTJ Device with 2 Dimensional Magnetic Field)

  • 이영우;김철기;김종오
    • 한국재료학회지
    • /
    • 제13권6호
    • /
    • pp.394-397
    • /
    • 2003
  • MTJ devices are fabricated using metal shadow masks and switching characteristics are investigated under 2 dimensional magnetic field. When the hard axis field is less than $\pm$ 16 Oe, switching behavior is similar to that based on the Stoner-Wohlfarth model. As the hard axis field is larger than $\pm$ 16 Oe, deviation from the expectation by Stoner-Wohlfarth model is observed. These phenomena are induced by the generation of multi-domain and inhomogeneous magnetization reversal.

퍼멀로이 특성을 기초로 한 고주파 센서에 사용되는 비정질 자성재료의 개발 (Design of Amorphous Magnetic Materials for high frequency Sensors Based Upon Permalloy Characteristics)

  • Yoo, C.K.;Kim, C.K.;Chung, Y.C.;O'handley, R.C.
    • 한국표면공학회지
    • /
    • 제32권6호
    • /
    • pp.677-685
    • /
    • 1999
  • 급속히 발전하고 있는 EPS 기술에 사용되고 있는 조화센서의 제조에 대해 연구하였다. 연구의 중점은 기본적으로 EPS 시스템에 사용되는 센서물질의 자성적 특성에 두었다. 조화 센서로서 사용되기 위한 주요 특징으로는 자기 이방성이 거의 0인 특서에서 기이나는 B-H곡선에서의 비선형성이다. 이와 관련하여 높은 신호를 발생하기 위한 자벽의 움직임과 자장열처리에 관하여 기술하였다.

  • PDF

Effect of Impregnation on Permalloy Powder Core

  • Kim, Hyo-Jin;You, Jae-Hyoung;Choi, Hyun-Sik;Kim, Gu-Hyun;Choi, Gwang-Bo;Han, Heung Nam;Yoo, Sang-Im
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2013년도 자성 및 자성재료 국제학술대회
    • /
    • pp.54-54
    • /
    • 2013
  • PDF

The Effect of Pinholes on Magnetic Behaviour of Antiferromagnetically Coupled Ni-Fe/Cu Mulitlayers

  • Stobiecki, F;Lucinski, T;Dubowik, J;Szymanski, B;Urbaniak, M;Castano, F.J;Stobiecki, T
    • Journal of Magnetics
    • /
    • 제3권3호
    • /
    • pp.89-91
    • /
    • 1998
  • The magnetisation behaviour of polycrystalline permalloy/copper multilayers with mixed antiferromagnetic/ferromagnetic coupling was investigated as function of temperature. The results are discussed in a framework of a realistic model of anitferromagnetically coupled layers connected by ferromagnetic pinholes. A microstructure of pinholes (their density and dimensions) was varied either by a proper annealing treatment or by choosing samples with various Cu spacer thicknesses. It was demonstrated that the temperature changes of the net magnetic moment measured in a magnetic field smaller than the saturation field was strongly affected by the composition of the pinholes, their density, cross-sectional area and their lengths.

  • PDF

자동 연소 법에 의한 $Ni_{1-x}-Zn_x ferrite$ 나노 입자의 합성 및 Permalloy 코팅 특성 ($Ni_{1-x}-Zn_x ferrite$ ferrite nano-particles prepared by the auto-conbustion method and the charateristics of the coated permallroy)

  • 최광보;김영식;김병철;김성배
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2002년도 동계연구발표회 논문개요집
    • /
    • pp.104-105
    • /
    • 2002
  • Ni$_{1-x}$-Zn$_{x}$ ferrite는 매우 큰 저항과 적은 eddy current loss를 가지고 있어 transfomer core나 radio frequency coil같은 high power device등의 전자 재료로 이용된다[1]. Ni$_{1-x}$-Zn$_{x}$ ferrite의 합성에는 여러 가지 방법이 이용되고 있으나 oxide/carbonate를 이용하여 120$0^{\circ}C$ 이상의 고온의 열을 가해 하소하는 solid-state reation과 diethylamine을 이용하여 metal nitrate를 공침 하는 coprecipition방법, sol-gel 방법 등의 wet chemical method가 가장 일반적이다[2-3]. (중략)

  • PDF

Spin Transport in a Ferromagnet/Semiconductor/Ferromagnet Structure: a Spin Transistor

  • Lee, W.Y;Bland, J.A.C
    • Journal of Magnetics
    • /
    • 제7권1호
    • /
    • pp.4-8
    • /
    • 2002
  • The magnetoresistance (MR) and the magnetization reversal of a lateral spin-injection device based on a spin-polarized field effect transistor (spin FET) have been investigated. The device consists of a two-dimensional electron gas (2DEG) system in an InAs single quantum well (SQW) and two ferromagnetic $(Ni_{80}Fe_{20})$ contacts: all injector (source) and a detector (drain). Spin-polarized electrons are injected from the first contact and, after propagating through the InAs SQW are collected by the second contact. By engineering the shape of the permalloy contacts, we were able to observe distinct switching fields $(H_c)$ from the injector and the collector by using scanning Kerr microscopy and MR measurements. Magneto-optic Kerr effect (MOKE) hysteresis loops demonstrate that there is a range of magnetic field (20~60 Oe), at room temperature, over which the magnetization in one contact is aligned antiparallel to that in the other. The MOKE results are consistent with the variation of the magnetoresistance in the spin-injection device.

용탕인출법으로 제조한 퍼말로이 박판의 Si 함량이 미세조직 및 자성특성에 미치는 영향 (Effect of Si Addition on Microstructure and Magnetic Properties of Permalloy Fabricated by Melt Drag Casting)

  • 임경묵;강주석;박찬경;남궁정;김문철
    • 소성∙가공
    • /
    • 제13권6호
    • /
    • pp.522-527
    • /
    • 2004
  • Permalloys were successfully fabricated by melt drag casting in the present study, and their microstructure and consequent magnetic properties have been investigated as a function of Si content. In order to understand the relationship between magnetic properties and Si content, microstructure and texture were observed and phase analysis were performed by TEM. The effective permeability went through a maximum value at $2\%$ Si and then decreased with increasing Si content. Increasing Si content enlarged grain size, which resulted in improvement of permeability. However, over-added Si caused the formation of $Ni_3Fe$ order phase so that $5\%$ Si added permalloys had the smallest permeability.

가스 분무법으로 제조된 NixFe100-x(x=40~50) 퍼멀로이 분말 및 압분 코아의 자기적 특성 (Magnetic Properties of NixFe100-x(x=40~50) Permalloy Powders and Dust Cores Prepared by Gas-Atomization)

  • 노태환;김구현;최광보;김광윤
    • 한국자기학회지
    • /
    • 제12권6호
    • /
    • pp.218-223
    • /
    • 2002
  • 가슨 분무법으로 제조한 High-Flux형 $Ni_{x}Fe_{100-x}$(x=40~50, wt.%) 퍼멀로이 분말 및 압분 코아의 자기적 특성을 조사하였다. 포화자화는 45%Ni조성에서 최대 값을 보이며 이보다 보 함량이 낮아지면 인바 효과의 작용에 의해 급격하게 감소하였다. 압분 코아의 투자율은 Ni 농도가 낮아지면 현저히 증가하는 바 이는 자기변형의 감소에 기인하는 것으로 사료되었으며, 자심손실은 Ni=45%에서 가장 낮은 값을 나타내었다. Ni농도가 50%에서 45%로 낮아짐에 따라 자심손실이 감소하는 주원인은 전기 비저항의 증대에 따른 와전류 손실의 감소에 있는 것으로 생각되었다. Ni=45% 분말 합금으로 만든 압분 코아는 Ni=50%의 경우보다 더 우수한 투자율의 주파수 의존성, 큰 Q 값, 그리고 더 나은 직류 바이어스 특성을 나타내어 상용 High-Flux 코아(50%Ni-50%Fe)에 비해 더 좋은 압분 자심 재료가 될 수 있음을 확인하였다.

반자성으로 커플링된 NiFe/Ru/NiFe 박막에서의 자기이방성의 변화 (Magnetic Anisotropy Behavior in Antiparallely Coupled NiFe/Ru/NiFe Films)

  • 송오성;정영순;이기영
    • 한국자기학회지
    • /
    • 제13권3호
    • /
    • pp.97-102
    • /
    • 2003
  • 고집적 TMR소자의 프리층에 적용될 수 있는 인위적페리층(synthetic ferrimagnetic layer : SyFL)인 NiFe/Ru/NiFe박막을 만들고, 결정에너지, 지만에너지, 교환에너지를 고려한 총에너지로부터 평형상태에서의 관계식에서 Ru두께에 따른 보자력( $H_{c}$)변화와, 스핀플로핑자계( $H_{sf}$ ), 포화자계( $H_{s}$)에 대해 알아보았다. Ta(50$\AA$)/NiFe(50$\AA$)Ru(4~20$\AA$)/NiFe(30$\AA$)/Ta(50$\AA$) 구조를 ICP (inductively coupled plasma)형 헬리콘스퍼터로 제작하고, 주어진 Ru두께에서의 시편을 SQUID로 $\pm$15kOe까지 분석하여 M-H루프를 측정하였다. 에너지를 고려한 평형상태 예측은 실험과 잘 일치하였으며, 이방성에너지 $K_{u}$= 1000erg/㎤, 교환에너지 $J_{ex}$= 0.7erg/$\textrm{cm}^2$까지 조절이 가능하였다. 상온에서 $H_{c}$를 10 Oe이하로 만드는 것이 가능하였고, 공업적으로 의미있는 $H_{s}$, $H_{sf}$ 의 범위를 Ru두께 4~10 $\AA$에서 선택이 가능하였다. 또한 50 $\AA$이하의 얇은 NiFe박막에서 자기탄성계수는 0이 아닌 (+)로 작용할 수 있다는 점과 NiFe/Ru 계면 조도를 간접적으로 예상하는 것이 가능하였다.

저성능 자기차폐실에서 64채널 DROS 2차 미분계 시스템의 잡음 특성 (Noise Characteristics of 64-channel 2nd-order DROS Gradiometer System inside a Poorly Magnetically-shielded Room)

  • 김진목;이용호;유권규;김기웅;권혁찬;박용기
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.33-39
    • /
    • 2006
  • We have developed a second-order double relaxation oscillation SQUID(DROS) gradiometer with a baseline of 35 mm, and constructed a poorly magnetically-shielded room(MSR) with an aluminum layer and permalloy layers for magnetocardiography(MCG). The 2nd-order DROS gradiometer has a noise level of 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz inside the heavily-shielded MSR with a shielding factor of $10^3$ at 1 Hz and $10^4-10^5$ at 100 Hz. The poorly-shielded MSR, built of a 12-mm-thick aluminum layer and 4-6 permalloy layers of 0.35 mm thickness, is 2.4mx2.4mx2.4m in size, and has a shielding factor of 40 at 1 Hz, $10^4$ at 100 Hz. Our 64-channel second-order gradiometer MCG system consists of 64 2nd-order DROS gradiometers, flux-locked loop electronics, and analog signal processors. With the 2nd-order DROS gradiometers and flux-locked loop electronics installed inside the poorly-shielded MSR, and with the analog signal processor installed outside it, the noise level was measured to be 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz on the average even though the MSR door is open. This result leads to a low noise level, low enough to obtain a human MCG at the same level as that measured in the heavily-shielded MSR. However, filters or active shielding is needed fur clear MCG when there is large low-frequency noise from heavy air conditioning or large ac power consumption near the poorly-shielded MSR.

  • PDF