• Title/Summary/Keyword: Perlite Pressure

Search Result 11, Processing Time 0.034 seconds

Dynamic Analysis of Expansion in Perlite (퍼라이트팽창의 동적해석)

  • Hahm, Yeong-Min
    • Applied Chemistry for Engineering
    • /
    • v.23 no.2
    • /
    • pp.143-147
    • /
    • 2012
  • Since the expansion of perlite occurs in a few second in high temperature, it is difficult to identify an expansion phenomenon through experiments. In order to explain this phenomenon, a numerical study has been carried out by setting a model that water vapour diffuses to a tiny bubble existing in perlite melts and then makes the bubble grow and perlite expand. When the bubble grew and the perlite expanded due to the diffusion of water vapour, the dynamic temperature of perlite decreased. Meanwhile, the dynamic pressure of bubble increased at the beginning as water vapour diffuses in melts, but rather decreased after a rapid expansion of bubble.

Structure Analysis and Design Optimization of Stiffeners in LNG Tanks (LNG 저장탱크 보강재의 구조해석 및 최적설계)

  • Jin, Cheng-Zhu;Jin, Kyo-Kook;Ha, Sung-Kyu;Seo, Heung-Seok;Yoon, Ihn-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.3
    • /
    • pp.325-330
    • /
    • 2012
  • This paper describes the structural analysis and optimization of stiffeners used in inner tanks for liquid natural gas (LNG) storage, so that the costs can be minimized while the critical buckling load of the inner tank still exceeds the external pressure exerted by the perlite. The original calculation of perlite pressure applied to the inner tank was based on Zick's code, which led to the overestimation of the external pressure, and consequently, an oversized stiffener. In this study, the effects of the material properties of perlite on the external pressure distribution are scrutinized, and the optimum dimensions of a single stiffener are finally obtained through a series of parametric studies. A 15% decrease in the cost of the stiffener compared with the original design is achieved.

Study on the characteristics of perlite insulation for the storage tank in LNG carrier (LNG선박 화물창의 펄라이트 단열재 적용성에 관한 설계 특성 연구)

  • Yun, Sangkook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.843-848
    • /
    • 2013
  • As the LNG demands are growing, the constructions of LNG FPSO (Floating Production Storage and Off-loading) and LNG carriers have been constantly increased, and the various design of storage tank has been tried. This paper propose that the material of inner storage tanks is made of 5~9% Ni steel plate and perlite powder insulation instead of urethane foam block. It needs essentially to obtain the proper design specifications that are the pressure of perlite, the characteristics of resilient blanket as the pressure absorber, optimum thickness of blanket and design pressure of tank wall, etc. to enable the perlite insulation system to LNG carrier, The results show that the design thickness of blanket should be between 1/4 to 1/3 of insulation width and the optimum rate becomes 30%, and the design pressure be applied below 1,500 Pa with blanket thickness.

Design Characteristics of Resilient Blanket as Pressure Absorber in the Insulation Annulus of LNG Tank (LNG내외탱크 사이의 압력흡수용 탄성 Blanket 설계 특성)

  • Yun, Sang-Kook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.77-82
    • /
    • 2013
  • The construction of LNG storage tanks has been increased due to the expansion of LNG demand. LNG tanks which consist of an inner cylindrical 9%Ni metal tank and reinforced concrete, are insulated with perlite powder and resilient blanket for absorbing the perlite pressure in insulation annulus between two inner and outer tanks. This study tries to find out the design specifications and characteristics for blanket thickness and design pressure. The results show that the design basis for the blanket thickness should be approximately 30% to 40% of annulus width and the design pressure be applied below 2,200~2,700Pa with blanket thickness.

Changes of Saturated Hydraulic Conductivity of Bed-soils Mixed with Organic and Inorganic Materials

  • Lee, Jeong-Eun;Kim, Yong;Yun, Seok-In
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.1
    • /
    • pp.66-70
    • /
    • 2014
  • Bed-soils can be used to help plants to overcome unfavorable conditions of soils, especially hydraulic properties of soils. This study was conducted to evaluate the effect of organic and inorganic raw materials on saturated hydraulic conductivity ($K_s$) of bed-soils. Perlite and bottom ash, which are inorganic materials, increased more $K_s$ of bed-soils than coco peat, an organic material. However, vermiculite, an inorganic material, increased less than coco peat. Saturated hydraulic conductivity of bed-soil mixed with fine vermiculite ($0.14{\pm}0.02mh^{-1}$) was much lower than one containing coarse vermiculite ($0.85{\pm}0.21mh^{-1}$). Such effect was more apparent when pressure was added on bed-soils containing fine vermiculite ($0.07{\pm}0.01mh^{-1}$), probably reflecting the decrease in pore size with the expansion of vermiculite wetted. Compacting decreased more $K_s$ in the bed-soils containing coco peat or vermiculite than other mixtures. Those results suggest that perlite and bottom ash in bed-soils play an important role in improving saturated hydraulic conductivity but vermiculite in bed-soils may suppress the improvement of saturated hydraulic conductivity with the decrease of its size and with the increase of compacting pressure.

Water Holding Capacity and Hydraulic Conductivity According to Compaction and Saturation Degree for Perlite amended with Ground Coir (압밀과 포화수준에 따른 분쇄 Coir 혼합 펄라이트의 수분보유력과 수리전도도)

  • Kim, Gi-Rim;Woo, Hyun-Nyung;Kim, Hye-Jin;Park, Mi-Suk;Song, Jin-A;Song, Tae-Yong;Jang, Hyo-Ju;Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.998-1003
    • /
    • 2011
  • This investigation was performed to determine the hydraulic conductivity coefficient and water holding capacity for a specified compaction forces which are the amount of mechanical energy applied to the porous granule (PG) volume. Most current specifications of minerals and perlite as growth media require to be compacted to a specified density, which in general is equivalent to a certain percentage of laboratory compaction. The water holding capacity of the saturated PG was very large at potential above -1 bar compared with perlite, but very little water remained below this value. The water holding capacity and hydraulic conductivity characteristics of graded PG amended with the ground coir less than 2 mm in diameter were also determined from pressure outflow data. The saturated hydraulic conductivity of the saturated and compacted PG was slightly lower by more than one tenth order of magnitude at equal matric potentials of perlite, but when expressed on the basis of equal water deficits, the conductivity of PG was higher at all but the smallest deficits than those of perlite.

Experimental research about thermal insulation performance of various powder insulation methods (다양한 파우더 충전 단열 방법의 단열 성능에 대한 실험적 연구)

  • Kim, H.S.;Jeong, S.;Jeong, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.49-54
    • /
    • 2010
  • This paper presents apparent thermal conductivity of various powder at different vacuum levels for cryogenic insulation. Four kinds of powder insulator are examined by using boil-off calorimetry at pressure range from 50 Torr to 3 mTorr. The first material is perlite which is widely used in cryogenic application. Microsphere is the second one that is recently proposed as a replacement powder for liquid hydrogen storage tanks. It is a hollow sphere made of silica with the diameter in the order of 10 to $100{\mu}m$. Popped rice and polystyrene beads are also selected as candidates for powder insulation even though they are polymers. With their porous elliptic and spherical configuration and light density, they demonstrate fairly good thermal insulation performance at pressure range from 50 Torr to 3 mTorr. According to the experimental investigation in this paper, microsphere and polystyrene beads possess promising insulation characteristic as powder insulators and further study is desired.

Three Phases and Water Characteristics of Horticultural Substrates (원예(園藝) 상토재료(床土材料)의 삼상(三相)과 수분특성(水分特性))

  • Jo, In-Sang;Hyun, Byung-Keun;Cho, Hyun-Jun;Jang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.1
    • /
    • pp.56-61
    • /
    • 1997
  • A study was carried out to find out the basic information in physical properties for selection and manufacturing the good seedling media through the analysis of the physical properties, such as particle size, water retention and three phases of the major horticultural substrates. Easily available water(EAW), the water contents between 1kPa and 5kPa water potental, was highest in peatmoss with 39%, and perlite 34.0%, vermiculite 16.9%, but the values of osmunda and bark were lower than 4.8%. Water buffering capacity(WBC), the water content between 5kPa and 10kPa, was 6.1% in peatmoss and 2.3% in vermiculite but it was lower than 1.0% in other substrates. To adjust the suitable range of water potential at crossing point of water and air curves to 1.5~2.5kPa, more finer materials were needed in osmunda and bark, and more coarser materials must be added to peatmoss, perlite and vermiculite. Water potentials of substrates in saturated pot condition were equivalent to 2.2kPa in peatmoss and others were ranged in 1.0kPa to 4.3kPa of water potential in pressure chamber.

  • PDF

Development of Biofilter for Reducing Offensive Odor from Pig House (돈사 악취 저감을 위한 바이오필터 개발)

  • Lee, Seung-Joo;Lim, Song-Soo;Chang, Dong-Il;Chang, Hong-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.4
    • /
    • pp.386-390
    • /
    • 2005
  • This study was conducted to develop the biofilter fur reducing ammonia $(NH_3)$ and hydrogen sulfide $(H_2S)$ gas emission from a pig house. A biofilter was designed and constructed by a type of squeeze air into the column type of air flow upward. Its column size was ${\Phi}260{\times}360mm$. It was used pressure drop gauge, turbo blower, air temperature, velocity sensor and control program that was programed by LabWindows CVI 5.5. Mixing materials were consisted with composted pine tree bark and perlite with 7:3 ratio (volume). The biofilter media inoculated with ammonia (Rhodococcus equi A3) and hydrogen sulfide (Alcaligenes sp. S5-5.2) oxidizing microorganisms was installed in a commercial pig house to analyzed the effectiveness of biogas removal for 10 days. Removal rates of ammonia and hydrogen sulfide gases were 90.8% and 81.5%, respectively. This result suggests that the pine compost-perlite mixture biofilter is effective and economic for reducing ammonia ana hydrogen sulfide gases.

Study on the High Temperature Properties of Fireproof Mortar Using Various Types of Fine Aggregate (잔골재 종류에 따른 내화피복용 모르타르의 고온 성상에 관한 연구)

  • Lim, Seo-Hyung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.2
    • /
    • pp.100-106
    • /
    • 2014
  • High strength concrete has a structural advantage as well as superior usability and durability, so that its application in building is being steadily augmented. However, in the high temperature like in a fire, the high strength concrete has extreme danger named explosive spalling. It is known that the major cause of explosive spalling is water vapour pressure inside concrete. General solution for preventing concrete from spalling include applying fire protection coats to concrete in order to control the rising temperature of members in case of fire. The purpose of this study is to investigate the high temperature properties of fireproof mortar using organic fiber and various types of fine aggregate for fire protection covering material. The results showed that addition of perlite and polypropylene fiber to mortar modifies its pore structure and reduces its density. This causes the internal temperature to rise. As a results, it is found that a new fireproof mortar can be used in the fire protection covering material in high strength concrete.