Browse > Article
http://dx.doi.org/10.5916/jkosme.2013.37.8.843

Study on the characteristics of perlite insulation for the storage tank in LNG carrier  

Yun, Sangkook (Division of Mechanical & Energy Systems Engineering, Korea Maritime University)
Abstract
As the LNG demands are growing, the constructions of LNG FPSO (Floating Production Storage and Off-loading) and LNG carriers have been constantly increased, and the various design of storage tank has been tried. This paper propose that the material of inner storage tanks is made of 5~9% Ni steel plate and perlite powder insulation instead of urethane foam block. It needs essentially to obtain the proper design specifications that are the pressure of perlite, the characteristics of resilient blanket as the pressure absorber, optimum thickness of blanket and design pressure of tank wall, etc. to enable the perlite insulation system to LNG carrier, The results show that the design thickness of blanket should be between 1/4 to 1/3 of insulation width and the optimum rate becomes 30%, and the design pressure be applied below 1,500 Pa with blanket thickness.
Keywords
LNG FPSO carrier; Perlite insulation; Resilient blanket; Design pressure; Design thickness;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Korea Gas Corporation, "LNG storage tank installed inside the ship and manufacturing method the tank." Korea, Patent 100499710000, June 28, 2005 (in Korean).
2 Samsung Heavy Industries, "Membrane structure and liquefied gas storage structure." Korea, Patent 1011296460000, March 16, 2012 (in Korean).
3 Hyundai Heavy Industries, "Membrane type cargo tank for liquefied gas, method of manufacturing the same and ship having the same." Korea, Patent 1011315360000, June 15, 2011 (in Korean).
4 H. A. Janssen, "Versuche uber getreidedruck in silozellen", CZ. Vereines Deutscher Ingenieure, 39, 1045-1049, 1895.
5 D. Singh, and E. B. Moysey, "Grain bin wall pressures: theoretical and experimental", Canadian Agricultural Engineering, vol. 27, no. 1, pp. 43-48, 1985.
6 The European Committee for Standardization, "Actions on structure - Part 4 : Silos ans tanks," EN 1991-4 (English) : Eurocode 1, 2006.
7 D. A. Wiegley, "Mechanical properties of materials at low temperatures", Plenum Press, New York, pp. 55-56, 1971.
8 I. M. Leadley, Technical Note for Mechanical Design of Shell Insulation, Technical Report, Preussag Co., Germany, 2009.