• 제목/요약/키워드: Periodic Testing

검색결과 81건 처리시간 0.028초

일부 TV부품 제조업체 남자 근로자들의 체력평가 기초연구 (Pilot Study for the Assessment of Physical Fitness among Male Workers in a TV Component Manufacturing Factory)

  • 최광서;이영하;김성희;우극현;한구웅;김두희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권3호
    • /
    • pp.531-545
    • /
    • 1994
  • In a TV component manufacturing factory, 102 male workers aged $20{\sim}39$ years old were participated in testing for physical fitness. At the same time, worker's periodic health examination was done. Test battery for physical fitness include grip strength, trunk flexion, standing long jump, side step, single leg balance with eye close, push ups and Harvard step test. As a result of testing for physical fitness, synthetically, there is no difference between manufacturing workers and officers. By bioelectrical impedance test, it means a declining tendency to all 7 factors in the obese workers, and so, it is important for obese workers not only to promote physical fitness but also to promote health. Excluding grip strength and single leg balance with eye close, 5 fitness factors are negatively associated with degree of diastolic Blood pressure, but it is statistically not significant. And levels of sGOT & sGPT have no association with physical fitness factors.

  • PDF

레일리각 근처에서 도색된 거친 표면으로부터 후방 산란된 초음파 (Ultrasonic Backscattering on Painted Rough Surface at near Rayleigh Angle)

  • 권성덕;권용규;윤석수
    • 비파괴검사학회지
    • /
    • 제24권1호
    • /
    • pp.1-7
    • /
    • 2004
  • [ $1.71{\mu}m$ ] 범위의 표면 거칠기를 가진 철 시편에 대해 물속에서 후방산란된 초음파의 입사각 의존성(프로파일)이 측정되었다. 거칠기가 도색에 의해 숨겨졌을 때 수직 프로파일은 거칠기에 대한 분별력이 사라졌으나 레일리 각 근처에서의 후방산란 프로파일은 거칠기 의존성을 여전히 보여주었다. 레일리 각에서 직접 복사된 프로파일 세기는 거칠기와 비례하였고 코너에서 반사되어 되돌아오는 표면파로부터의 후방복사의 세기는 거칠기와 반비례하였다. 도색 처리된 시편에서 0.03 파장 이하의 직접 후방복사에서도 선형성이 관찰되었고 주기적 거칠기에 의해 발생한 비정상 저면 다중반사 현상이 사라졌다.

중수로 연료관 검사시스템 개발 (Development of Fuel Channel Inspection System in PHWR)

  • 최성남;양승옥;김광일;이희종
    • 비파괴검사학회지
    • /
    • 제36권1호
    • /
    • pp.60-67
    • /
    • 2016
  • 가압중수로는 운전중 연료교체가 가능하도록 설계된 연료관에서 핵분열을 유도하여 에너지를 얻는다. 연료관은 핵연료와 직접 접촉하며 원자로 냉각재의 통로인 압력관, 주위 감속재와 접촉하며 원자로에 확관된 원자로관, 이것을 양쪽에서 지지하는 엔드피팅과 압력관과 원자로관의 접촉을 방지하기 위한 스페이서 등으로 구성되어 있다. 연료관은 가장 안전성이 요구되는 설비이므로, 캐나다 기술기준 CSA N 285.4에 따라 주기적이고 철저한 가동중검사를 수행하여 건전성을 확인한다. 월성 중수로 연료관의 가동중검사를 수행하기 위해 연료관 검사시스템을 개발하였다. 본 논문은 월성 연료관 현장시험 결과를 검토하고, 개발된 연료관 검사시스템의 유효성을 확인하였다.

Comparative assessment of surface and ground water quality using geoinformatics

  • Giridhar, M.V.S.S.;Mohan, Shyama;Kumar, D. Ajay
    • Advances in environmental research
    • /
    • 제9권3호
    • /
    • pp.151-160
    • /
    • 2020
  • Water quality demonstrates physical, chemical and biological characteristics of water. The quality of surface and groundwater is currently an important concern with population growth and industrialization. Over exploitation of water resources due to demand is causing the deterioration of surface water and ground water. Periodic water quality testing must be carried out to protect our water resources. The present research analyses the spatial variation of surface water and groundwater in and around the lakes of Hyderabad. Twenty-Seven lakes and their neighboring bore water samples are obtained for water quality monitoring. Samples are evaluated for specific physico-chemical parameters such as pH, Total Dissolved Solids (TDS), Cl, SO4, Na, K, Ca, Mg, and Total Hardness (TH). The spatial variation of water quality parameters for the 27 lakes and groundwater were analysed. Correlation and multiple regression analysis were carried out to determine comparative study of lake and ground water. The study found that most of the lakes were polluted and this had an impact on surrounding ground water.

Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Sang-Kil;Kim, Beom-Soo;Kim, Doo-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1086-1092
    • /
    • 2015
  • The off-line and on-line partial discharge (PD) in the stator winding of three high-voltage (HV) motors (1,400 HP, 6.6 kV) is measured and analyzed in this paper. The off-line PD is measured at high values between 24,300 ~ 36,100 pC after 18 years of motor operation. Spare replacement motors were not available for testing the degree of deterioration of the stator windings in standstill status. Therefore, on-line periodic analysis was conducted to monitor the trend of PD after installing a ceramic sensor (110 pF, 6.6 kV) in the terminal box for each phase of each motor. In the stator winding of the No.1 and No.2 HV motors, which showed high magnitudes of off-line PD and low magnitudes of on-line PD, defects are expected to appear in the neutral end of the winding. On the contrary, in the stator windings of the No.3 HV motor, which exhibits high off-line and on-line PD magnitude, defects are expected to appear in the terminal end of the winding where a voltage close to the phase voltage is applied.

알루미늄 합금 대기부식 예방을 위한 대한민국 공군 항공기 세척주기 최적화 연구 (Wash Interval Optimization to Prevent Atmospheric Corrosion of Korean Aircrafts Made of Aluminum Alloys)

  • 박원동;국필준;조윤호;반치범
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.189-197
    • /
    • 2016
  • It is a common practice to conduct periodic washes at designated intervals in order to prevent the atmospheric corrosion of aircraft. The wash interval depends on the atmospheric conditions, but the wash intervals set by the U.S. Air Force were widely adopted in Korea without detailed knowledge of the background data. Therefore, it is necessary to determine our own wash intervals representing the atmospheric and geographical conditions in Korea. This study analyzed previous wash interval algorithms and atmospheric data in Korea. New wash intervals are then proposed based on the corrosion rate equation in ISO-9223:2012. Atmospheric corrosion testing was conducted using 7075 and 1050 aluminum alloy specimens to verify the accuracy of the corrosion rate equation in ISO-9223:2012. Test results showed a reasonable agreement with the corrosion rates predicted by the equation.

Modern Cause and Effect Model by Factors of Root Cause for Accident Prevention in Small to Medium Sized Enterprises

  • Kang, Youngsig;Yang, Sunghwan;Patterson, Patrick
    • Safety and Health at Work
    • /
    • 제12권4호
    • /
    • pp.505-510
    • /
    • 2021
  • Background: Factors related to root causes can cause commonly occurring accidents such as falls, slips, and jammed injuries. An important means of reducing the frequency of occupational accidents in small- to medium-sized enterprises (SMSEs) of South Korea is to perform intensity analysis of the root cause factors for accident prevention in the cause and effect model like decision models, epidemiological models, system models, human factors models, LCU (life change unit) models, and the domino theory. Especially intensity analysis in a robot system and smart technology as Industry 4.0 is very important in order to minimize the occupational accidents and fatal accident because of the complexity of accident factors. Methods: We have developed the modern cause and effect model that includes factors of root cause through statistical testing to minimize commonly occurring accidents and fatal accidents in SMSEs of South Korea and systematically proposed educational policies for accident prevention. Results: As a result, the consciousness factors among factors of root cause such as unconsciousness, disregard, ignorance, recklessness, and misjudgment had strong relationships with occupational accidents in South Korean SMSEs. Conclusion: We conclude that the educational policies necessary for minimizing these consciousness factors include continuous training procedures followed by periodic hands-on experience, along with perceptual and cognitive education related to occupational health and safety.

압연 제조된 STS439/Al1050/ STS304 Clad소재의 열처리에 따른 계면 반응과 기계적 특성에서의 계면 반응 효과 (Interfacial Reaction on Heat Treatment of Roll-bonded STS304/Al1050/STS439 Clad Materials and its Effect on the Mechanical Properties)

  • 송준영;김인규;이영선;홍순익
    • 대한금속재료학회지
    • /
    • 제49권11호
    • /
    • pp.910-915
    • /
    • 2011
  • The microstructures and mechanical properties of roll-bonded STS439/Al1050/STS304 clad materials were investigated after an annealing process at various temperatures. Interfacial layer was developed at the STS439/Al1050 and Al1050/STS304 interfaces at $550^{\circ}C$. STS439/Al1050/STS304 clad metals fractured suddenly in a single step and the fracture decreased with increasing annealing temperatures at $450^{\circ}C$. After annealing at $550^{\circ}C$, samples fractured in three steps with each layer fracturing independently. Interfacial layers formed at $550^{\circ}C$ with a high Vickers microhardness were found to be brittle. During tensile testing, periodic parallel cracks were observed at the interfacial reaction layer. Observed micro-void between Al1050 and the interfacial layer was found to weaken the Al1050/reaction layer interface, leading to the total separation between Al1050 and the reaction layer.

종이접기 구조의 자세 파악을 위한 폴딩 센서 개발 (Estimation of the State of Folding Structures using a Novel Sensor)

  • 채수빈;정광필
    • 센서학회지
    • /
    • 제30권2호
    • /
    • pp.88-93
    • /
    • 2021
  • In this paper, a folding sensor based on capacitance is proposed. The sensor was developed to sense the length and angle data for the milli-scale actuators without causing any interference to the actuating joints. For the sensing and testing the robotic joint with reducing the cost and complexity aspects of manufacturing, a simple composition was adopted. The sensor comprises a pair of copper tapes, papers, and wires. The complete sensing unit is constructed by bonding the tapes with the papers and soldering the wire to the copper parts. For accuracy, a teensy 4.0 board, which has a 12-bit ADC resolution, is employed. Furthermore, the sensed analog data is not translated into the unit of capacitance for accuracy; however, it is filtered using a low-pass filter and subsequently, a Butter-worth filter. The data obtained demonstrate a periodic waveform, which implies that the data are in good agreement with the hypothesis set prior to the experiments. Compared to other milli-scale sensors, this could be a better option for sensing the length and angle data for milliscale actuators.

Slip-resistant bolted connections under freeze-thaw cycles and low temperature

  • A. Fuente-Garcia;M.A. Serrano-Lopez;C. Lopez-Colina;F., Lopez-Gayarre
    • Steel and Composite Structures
    • /
    • 제48권3호
    • /
    • pp.251-262
    • /
    • 2023
  • There are many examples of steel structures subjected to severe environmental conditions with bolted connections directly exposed to extreme climatic agents such as freeze-thaw cycles or low temperatures. Some examples are: steel bridges, mining transfer towers, wind towers... These service conditions neither are included in Eurocode 3 or EN1090-2, nor there are references in other international standards. In this experimental research, 46 specimens of non-slip joints with HV M20 bolts and four different types of contact surfaces have been studied. Half of the specimens were subjected to fourteen twelve-hours freeze-thaw cycles, with periodic immersion in water and temperature oscillation. Subsequently, half of the connections were subjected to a slip test under monotonic load at temperature of -20 ± 0.5 ℃ and the other half at room temperature. The results were compared with others equal joints not subjected to freeze-thaw cycles and kept at room temperature for the same time. This finally resulted in 4 sets of joints by combining the freeze-thaw degradation or not with the low-temperature conditions or not in the slip testing. Therefore, a total of 16 different conditions were studied by also considering 4 different contact surfaces between the joined plates in each set. The results obtained show influence of environmental conditions on the slip resistant capacity of these joints.