• Title/Summary/Keyword: Performance verification

Search Result 2,561, Processing Time 0.032 seconds

A Load Emulator for Low-power Embedded Systems and Its Application (저전력 내장형 시스템을 위한 부하의 전력 소모 에뮬레이션 시스템과 응용)

  • Kim, Kwan-Ho;Chang, Nae-Hyuck
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.6
    • /
    • pp.37-48
    • /
    • 2005
  • The efficiency of power supply circuits such as DC-DC converters and batteries varies on the trend of the power consumption because their efficiencies are not fixed. To analyze the efficiency of power supply circuits, we need the temporal behavior of the power consumption of the loads, which is dependent on the activity factors of the devices during the operation. Since it is not easy to model every detail of those factors, one of the most accurate power consumption analyses of power supply circuits is measurement of a real system, which is expensive and time consuming. In this paper, we introduce an active load emulator for embedded systems which is capable of power measurement, logging, replaying and synthesis. We adopt a pattern recognition technique for data compression in that long-term behaviors of power consumption consist of numbers of repetitions of short-term behaviors, and the number of short-term behaviors is generally limited to a small number. We also devise a heterogeneous structure of active load elements so that low-speed, high-current active load elements and high-speed, low-current active load elements may emulate large amount and fast changing power consumption of digital systems. For the performance evaluation of our load emulator, we demonstrate power measurement and emulation of a hard drive. As an application of our load emulator, it is used for the analysis of a DC-DC converter efficiency and for the verification of a low-power frequency scaling policy for a real-time task.

Manufacturing and Structural Analysis of Thick Composite Spar Using AFP Machine (AFP로 제작된 두꺼운 복합재료 스파의 제작 및 구조 해석)

  • Kim, Ji-Hyeon;Han, Jun-Su;Bae, Byung-Hwan;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.212-218
    • /
    • 2015
  • A large composite spar was manufactured using an automatic fiber placement (AFP) machine. To verify its structural performance, the weakest part of the structure, which is called 'corner radius', was tested under bending and examined by finite element analysis. Since the application of AFP machine to composite structure fabrication is still in early stage in Korea, this paper presents the summary of whole process for manufacturing composite spar using AFP machine from mandrel design and analysis to verification test. The deflection and stress by mandrel weight and AFP machine force, thermal deformation and natural frequency were all examined for mandrel design. The target structure was composite C-spar and cured in an autoclave. Test results were compared with nonlinear finite element analysis results to show that the structure has the strength close to the theoretical value. It was confirmed that the corner radius of the spar manufactured by AFP process showed deviation less than 20% compared with first ply failure strength. The results indicate that the AFP technology could be used for large scale composite structure production in the near future.

A Study on Improvement of Modular Specifications - Focused on technical specifying method in waterproof and mechanical works - (모듈러 공사시방서 개선방안에 관한 연구 - 방수 및 기계설비공사의 기술방안 개선을 중심으로 -)

  • Yoon, Jongsik;Shin, Dongwoo;Cha, Heesung;Kim, Kyungrai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.3
    • /
    • pp.33-41
    • /
    • 2017
  • A modular specification is a contract document that specifies the requirements of production, transformation and installation in a modular construction. A problem of the currently used specification is that it does not guarantee the level of performance required by the modular construction and fails to accommodate unique characteristics of each construction because it widely uses the standard specification as it is. This study proposes a specification that reflects the unique feature of modular construction in order to improve the quality of modular construction. Research focuses on the leakage in waterproof and mechanical equipment because it is the area with the highest rate of defects. This study suggests ways to improve the modular specification as follows: 1)Descriptive specifying (following MasterFormat) 2)Propose leakage verification method and test clause 3) Reflect characteristic of modular construction. Proposed modifications to modular specification are reviewed by experts for validation and their opinion verifies suggested improvements as a way to secure the quality of modular construction and to promise characteristics of the modular specification. This improvement will be used for reference when writing construction project specification, which can be an important contract document, so that it could lower occurrence rate of the modular defects.

Content Analysis of the Teaching Support Program of the Teaching and Learning Center and Direction of the Teaching Support Platform (교수학습센터의 교수지원 프로그램 컨텐츠 분석 및 교수지원 플랫폼이 나아갈 방향)

  • Cho, Bo-Ram
    • Journal of Digital Convergence
    • /
    • v.18 no.10
    • /
    • pp.1-12
    • /
    • 2020
  • This is a study on the direction of the teaching support program contents analysis and teaching support platform of the teaching and learning center. To this end, in April 2020, a literature study was conducted, an analysis of the current status of teaching support at other universities and K universities, an analysis of professor interviews, and expert verification were conducted. The main research results are as follows. First, as a result of examining the current status of teaching support programs at 24 universities, it was confirmed that special lectures on teaching methods, class consulting, teaching method research meetings, and educational resource rooms were operated as representative programs. Second, the basic structure of the platform is composed of a lecture case sharing bulletin board to enable active exchange of opinions on teaching methods among teachers, a teaching support program application bulletin board to enable application for a teaching method program, and Edu-tech to activate the platform, and a professor support menu. Third, the contents of the teaching support platform were implemented based on the basic structure of the teaching support platform. This study analyzed the contents of the teaching support program and conducted a study to suggest the direction of the teaching support platform to discuss the direction of establishing an effective teaching support platform.

Low-speed Impact Localization on a Stiffened Composite Structure Using Reference Data Method (기준신호 데이터를 이용한 보강된 복합재 구조물에서의 저속 충격위치 탐색)

  • Kim, Yoon-Young;Kim, Jin-Hyuk;Park, Yurim;Shrestha, Pratik;Kwon, Hee-Jung;Kim, Chun-Gon
    • Composites Research
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Low-speed impact was localized on a stiffened composite structure, using 4 FBG sensors with 100 kHz-sampling rate interrogator and devised localization algorithm. The composite specimen consists of a main spar and several stringers, and the overall size of the specimen's surface is about $0.8{\times}1.2m$. Pre-stored reference data for 247 grid locations and 36 stiffener locations are gathered and used as comparison target for a random impact signal. The proposed algorithm uses the normalized cross-correlation method to compare the similarities of the two signals; the correlation results for each sensor's signal are multiplied by others, enabling mutual compensation. 20 verification points were successfully localized with a maximum error of 43.4 mm and an average error of 17.0 mm. For the same experimental setup, the performance of the proposed method is evaluated by reducing the number of sensors. It is revealed that the mutual compensation between the sensors is most effective in the case of a two sensor combination. For the sensor combination of FBG #1 and #2, the maximum localization error was 42.5 mm, with average error of 17.4 mm.

Verifying a Safe P2P Security Protocol in M2M Communication Environment (M2M 통신환경에서 안전한 P2P 보안 프로토콜 검증)

  • Han, Kun-Hee;Bae, Woo-Sik
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.213-218
    • /
    • 2015
  • In parallel with evolving information communication technology, M2M(Machine-to-Machine) industry has implemented multi-functional and high-performance systems, and made great strides with IoT(Internet of Things) and IoE(Internet of Everything). Authentication, confidentiality, anonymity, non-repudiation, data reliability, connectionless and traceability are prerequisites for communication security. Yet, the wireless transmission section in M2M communication is exposed to intruders' attacks. Any security issues attributable to M2M wireless communication protocols may lead to serious concerns including system faults, information leakage and privacy challenges. Therefore, mutual authentication and security are key components of protocol design. Recently, secure communication protocols have been regarded as highly important and explored as such. The present paper draws on hash function, random numbers, secret keys and session keys to design a secure communication protocol. Also, this paper tests the proposed protocol with a formal verification tool, Casper/FDR, to demonstrate its security against a range of intruders' attacks. In brief, the proposed protocol meets the security requirements, addressing the challenges without any problems.

A study of using quality for Radial Basis Function based score-level fusion in multimodal biometrics (RBF 기반 유사도 단계 융합 다중 생체 인식에서의 품질 활용 방안 연구)

  • Choi, Hyun-Soek;Shin, Mi-Young
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.5
    • /
    • pp.192-200
    • /
    • 2008
  • Multimodal biometrics is a method for personal authentication and verification using more than two types of biometrics data. RBF based score-level fusion uses pattern recognition algorithm for multimodal biometrics, seeking the optimal decision boundary to classify score feature vectors each of which consists of matching scores obtained from several unimodal biometrics system for each sample. In this case, all matching scores are assumed to have the same reliability. However, in recent research it is reported that the quality of input sample affects the result of biometrics. Currently the matching scores having low reliability caused by low quality of samples are not currently considered for pattern recognition modelling in multimodal biometrics. To solve this problem, in this paper, we proposed the RBF based score-level fusion approach which employs quality information of input biometrics data to adjust decision boundary. As a result the proposed method with Qualify information showed better recognition performance than both the unimodal biometrics and the usual RBF based score-level fusion without using quality information.

Experimental Verification of a Liquid Damper with Changeable Natural Frequency for Building Response Control (고유진동수 조절이 가능한 액체댐퍼의 건물응답 제어실험)

  • Kim, Dong-Ik;Min, Kyung-Won;Park, Ji-Hun;Kim, Jae-Keon;Hwang, Kyu-Seok;Gil, Yong-Sik
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.323-330
    • /
    • 2012
  • This study deals with the experiments of liquid dampers with multi cells whose vertical tubes are divided into several square columns for easily changing natural frequencies. Shaking table test is performed to verify control effectiveness of the dampers which are installed on a building structure. To design liquid dampers, a 64-story building structure is reduced to a SDOF structure with 1/20 of similitude laws based on acceleration. The structure model is made up to adjust its mass and stiffness easily, with separate mass and drive parts. Mass parts indicate real structure's weights and drive parts indicate real structure's stiffness with springs and LM guides. Manufactured liquid damper has 18 cells and its natural frequency ranges are 0.65Hz to 0.81Hz. Shaking table test is carried out with one way excitation to compare with only accelerations of a large-scale structure and a structure installed with liquid dampers. Control performance of the liquid damper is expressed by the transfer function from shaking table accelerations to the large-scale structure ones. Testing results show that the liquid damper reduced a large-scale structure's response by tuned natural frequencies.

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

Evaluation of Ground Thermal Conductivity by Performing In-Situ Thermal Response test (TRT) and CFD Back-Analysis (현장 열응답 시험(TRT)과 CFD 역해석을 통한 지반의 열전도도 평가)

  • Park, Moonseo;Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.5-15
    • /
    • 2012
  • In this study, a series of CFD (Computational Fluid Dynamics) numerical analyses were performed in order to evaluate the thermal performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju. The circulation HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The simulation results provide a verification for the in-situ thermal response test (TRT) data. The CFD numerical back-analysis with the ground thermal conductivity of 4 W/mK yielded better agreement with the in-situ thermal response tests than with the ground thermal conductivity of 3 W/mK.