Construction of the infrastructure for evaluating characteristic against contamination for power installation (전력기기 내오손특성 평가기반 구축)

  • Lee, J.G.;Kim, M.K.;Moon, I.W.;Jeong, J.Y.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1513-1514
    • /
    • 2006
  • In this paper, there have been brief review about the important consideration in laboratory planning and construction of the artificial pollution testing facilities including 300 kV, 1800 kVA AC test system, which enable to lest and evaluate the UHV dielectric performance of power insulators up to transmission class. Also it is described simply about its trial running of the whole test system. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.

  • PDF

An Evaluation of Selective Grounding Fault Protective Relaying Technique Performance on the Ungrounded DC Traction Power Supply System (도시철도 직류 비접지 급전계통에서의 선택 지락보호시스템의 성능평가)

  • Jung, Hosung;Kim, Joouk;Shin, Seongkuen;Kim, Hyungchul;An, Taepung;Yun, Junseok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1964-1969
    • /
    • 2012
  • This paper presents to verify the selective grounding fault protective relaying technique for the ungrounded DC traction power supply system. This system selectively blocks fault section when grounding fault occurred. In order to perform this verification, field test facilities have been installed on Oesam substation and Worldcup-Stadium substation, and field test process has been suggested. Also, selective grounding fault protective relaying components and rail voltage reduction device have been tested with the various trial examinations. In order to compare and evaluate performance of the selective grounding fault protective relaying function, field test system was modeled and the system fault simulation results were compared and evaluated with the field test result. Performance of selective grounding fault protective relaying function was evaluated with the above-mentioned process, and the fact that the system recognizes fault section irrespective of insulation between rail and ground and fault resistance from grounding fault.

Performance of growing lambs supplemented with ground licuri (Syagrus coronata)

  • Daza, Adin;Souza, Jocely G.;Monnerat, Joao Paulo I.S.;Ribeiro, Claudio V.D.M.
    • Animal Bioscience
    • /
    • v.34 no.6
    • /
    • pp.1014-1021
    • /
    • 2021
  • Objective: The aim of this study was to determine the effect of dietary ground licuri on lamb performance. Methods: Forty male lambs were used in a completely randomized design to test the effects of 0, 5, 10, and 15 g/kg of ground licuri added to diets. The trial lasted for 75 days. Intake, digestibility, physically effective neutral detergent fiber, and chewing activity were estimated. Blood samples were taken on day 45 to determine the concentrations of glucose, urea, non-esterified fatty acids, and triglycerides. Average daily gain (ADG) were determined on the last day of the experimental trial. Results: Licuri inclusion markedly increased dietary neutral detergent fiber and ether extract (EE) content, but it decreased dry matter (DM) intake. However, the intake and digestibility of EE linearly increased. The ADG decreased linearly (p<0.05) with licuri inclusion. Licuri had no effect (p>0.05) on the concentrations of blood metabolites; however, blood urea increased (p<0.05), while serum glucose decreased (p<0.05). Conclusion: The physically effective fiber of ground licuri is similar to Tyfton hay and licuri inclusion decreases lamb performance due to a decreased in DM intake.

Development of Multi-purpose Marine Wastes Cleaning Systems for the Shallow Waters(PART II : System Development and Performance Evaluation) (천수용 다기능 해양폐기물 수거시스템 개발(PART II : 시스템 구성 및 성능시험))

  • Cho Yong-Jin;Moon Il-Sung;Shin Myung-Soo;Yu Jeong-Seok;Kang Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • This paper - following 'Development of multi-purpose marine waste cleaning systems for the shallow waters (Part I : preliminary conceptual design)'- describes on the system development and the sea trial performance evaluation(Cho[2003]). The multi-functional seabed waste collecting system and the towing hook system were developed. The maximum working depth of these systems are 15 and 100 meters, respectively(MOMAF[2001]). For the multi-purpose use to collect the marine waste, this system contains floating waste collecting device for the waste on seawater and remained waste collecting device for the waste on seabed, while steel wire cutting system is added for higher efficiency In order to evaluate the system performance, the prototype of multi-functional system was constructed and the sea trial test at shallow water were carried out. As a result, this system operated well with safe and without any interaction so that the developed systems are practicable and applicable.

  • PDF

A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System (다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구)

  • Kim, You Rim;Yu, Woo Jin;Park, Ho Joon;Jang, Won Seuk
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.

Study on the Mechanical Face Seal Performance for a 7-ton-Class Turbopump (7톤급 터보펌프 기계평면실의 성능 시험 연구)

  • Bae, Joonhwan;Kwak, Hyun D.;Choi, Changho
    • Tribology and Lubricants
    • /
    • v.32 no.5
    • /
    • pp.154-159
    • /
    • 2016
  • This paper presents an experimental study of the leakage performance and endurance performance of a mechanical face seal in the 7-ton-class turbopump of the Korea Space Launch Vehicle 2 third-stage engine. We install a mechanical face seal between the fuel pump and turbine to prevent the mixing of the fuel and turbine gas. We design and manufacture a prototype mechanical face seal, which has two parts, namely, a bellows seal assembly and mating ring. We set up a test facility to measure the leakage and endurance of the mechanical face seal. For the similarity tests, we use water under real operating conditions such as high rotational speed, high temperature, and high pressure. Through investigation of the leakage and carbon wear rate, it is possible to evaluate the performance of the mechanical face seal. The results of the leakage and endurance performance test demonstrate the absence of any leakage from the prototype mechanical face seal after a trial run and clarify that the acceptable wear rate fully satisfies the turbopump requirements. Finally, we install a qualified mechanical face seal in a 7-ton-class turbopump and perform a validation test in the turbopump real-propellant test facility in the Korea Aerospace Research Institute. The test results confirm that the mechanical face seal works well under real operating conditions.

Performance Evaluation of 20 HP Outboard Motor in Consideration of Driving System Applied to Electric-Propulsion Boat (전기추진 선박에 적용되는 20HP급 전기추진 선외기 구동시스템의 성능평가에 대한 고찰)

  • Moon, Byung Young;Shin, Kuk Hwan;Lee, Ki Yeol
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.518-526
    • /
    • 2018
  • As a new technical approach, this paper introduces a method for improving an electrically propelled outboard motor in consideration of the driving system applied to an electric-propulsion boat with solar cell energy. The most efficient model for a drive shaft, propeller shaft, and bevel gear was suggested and examined with respect to the results of test operation in prototype mode. Furthermore, this research included a performance evaluation of the manufactured prototype to acquire the purposed quantity value and the development items. After manufacturing the desired prototype of an electrically propelled outboard motor, the maximum sail time, thrust force, noise, and weight were evaluated in a performance test. An additional test in relation to the maximum sail speed (knots) of the completed prototype was conducted using a sea trial evaluation to acquire the optimum quantity.

Design of Course Keeping Controller for RIB-type USV Using a Pilot's Steering Pattern (조종자 입력패턴을 활용한 RIB형 무인선의 침로제어기 설계)

  • Yun, Kun-Hang;Yeo, Dong-Jin;Yoon, Hyeon-Kyu
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.3
    • /
    • pp.462-468
    • /
    • 2010
  • A new course keeping controller for RIB(Rigid Inflatable Boat)-type USV(Unmanned Surface Vehicle) is developed using pilot's steering pattern. A pilot's simple steering pattern is found out from various course change tests. It is used to course keeping algorithm, suitable for large course change more than 60 degrees. To validate the course keeping controller, sea trial tests are conducted. From sea trial test, new course keeping controller shows good performance with less overshoot, maximum roll angle less than $20^{\circ}$, which makes it possible that fast course changes without slip motion of USV.

Development of an electronic starter using a half-wave rectifier for fluorescent lamps (반파정류를 이용한 형광램프용 전자식 스타터의 개발)

  • Lee, Dong-Ho;Song, Song-Bin;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2088-2090
    • /
    • 1998
  • A low-cost electronic starter is developed to decrease ignition failure significantly through successive starting trial and to prevent overheating at the end of fluorescent lamp life. Moreover, it has an additional feature of being capable of ignition at the recovered lamp voltage without any circuit correction. The developed electronic starter is consisted of four parts - a half wave rectifier circuit, a timer circuit, a switching circuit and a protection circuit. The protection circuit made up of a transistor and capacitors utilizing capacitive characteristics, carries out successive starting trial and end-of-life protection. Lamp ignition is completed within 0.5 seconds with taking advantage of a high preheating current from the half-wave rectifier circuit. Nevertheless, its performance is proved to be very excellent through a standard switching endurance test.

  • PDF

Material Properties of Arctic Sea Ice during 2010 Arctic Voyage of Icebreaking Research Vessel ARAON: Part 2 - Compressive Strength, Flexural Strength, and Crystal Structures (쇄빙연구선 ARAON호를 이용한 북극해 해빙의 재료특성 (2) - 해빙의 압축강도, 굽힘강도 및 결정구조 -)

  • Kim, Dae-Hwan;Park, Young-Jin;Choi, Kyung-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • To correctly estimate ice load and ice resistance for a ship's hull, it is essential to understand the material properties of sea ice during ice field trials and to use the proper experimental procedure for gathering ice strength data. The first Korean-made icebreaking research vessel (IBRV), ARAON, had her second sea ice trial in the Arctic Ocean during July and August of 2010. This paper describes the test procedures used to properly obtain sea ice strength data, which provides the basic information on the ship's performance in an ice-covered sea and can be used to estimate the correct ice load and ice resistance on the IBRV ARAON. The data gathered from three sea ice field trials during the Arctic voyage of the ARAON includes the ice compressive strength, flexural strength, and failure strain of sea ice. This paper analyzes the gathered sea ice data in comparison with data from the first voyage of the ARAON during her Antarctic Sea ice trial in January 2010.