Proceedings of the KIEE Conference (대한전기학회:학술대회논문집)
- 2006.07c
- /
- Pages.1513-1514
- /
- 2006
Construction of the infrastructure for evaluating characteristic against contamination for power installation
전력기기 내오손특성 평가기반 구축
- Lee, J.G. (Reliability Assessment Center, KERI) ;
- Kim, M.K. (Reliability Assessment Center, KERI) ;
- Moon, I.W. (Reliability Assessment Center, KERI) ;
- Jeong, J.Y. (Reliability Assessment Center, KERI) ;
- Kim, I.S. (Reliability Assessment Center, KERI)
- 이정기 (한국전기연구원 신뢰성평가센터) ;
- 김민규 (한국전기연구원 신뢰성평가센터) ;
- 문인욱 (한국전기연구원 신뢰성평가센터) ;
- 정주영 (한국전기연구원 신뢰성평가센터) ;
- 김익수 (한국전기연구원 신뢰성평가센터)
- Published : 2006.07.12
Abstract
In this paper, there have been brief review about the important consideration in laboratory planning and construction of the artificial pollution testing facilities including 300 kV, 1800 kVA AC test system, which enable to lest and evaluate the UHV dielectric performance of power insulators up to transmission class. Also it is described simply about its trial running of the whole test system. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.
Keywords