• Title/Summary/Keyword: Performance limit

Search Result 2,460, Processing Time 0.032 seconds

Hybrid d-step prediction design with improved prediction performance (향상된 성능을 갖는 혼합 d-step 예측기 설계)

  • 김윤선;윤주홍;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.145-145
    • /
    • 2000
  • In this paper, we propose a hybrid d-step predictor which is composed of an adaptive predictor and a Kalman predictor. We prove the performance limit of the proposed predictor. Simulation is conducted to examine the performance of the proposed predictor. Simulation results show that the proposed combined predictor is superior to the adaptive predictor and the Kalman predictor. Proposed predictor is used for prediction of gun tip vibration of k1 tank. The result is compared with that of conventional adaptive predictor.

  • PDF

A study on the operation performance control of urban rail vehicle using an optimal control (최적제어를 이용한 도시철도 차량 주행제어 연구)

  • Tak Kil Hun;Kim Dong-Hwan;Kim Chi Tae
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.107-112
    • /
    • 2005
  • When it comes to automatic operation control of urban rail vehicle, a PID control makes it run between stations within the fixed time and stop exactly at the stop sign on the platform, satisfying jerk limit. An optimal control is applied to automatic operation performance control to minimize energy consumption while the urban rail vehicle satisfies automatic operation condition on this paper. The control performance in terms of energy minimization along with the constraint on precision stops is compared between the optimal control and PID control.

  • PDF

Fire Performance of Structural Lightweight Aggregate Concrete using PP fiber (PP섬유 혼입 고강도 경량골재콘크리트의 내화특성)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.797-800
    • /
    • 2006
  • Normally, Structural light-weight aggregate concrete(LWC) has been main used in high rise building with the object of wight loss. In spite of LWC have the advantage of light-weight, limit the use of strength restrictions by reason that explosive spalling in fire. Especially, LWC is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with fire performance of LWC for the purpose of using PP fibers prevent to explosive spalling. From the experimental test result, LWC is happened explosive spalling.

  • PDF

Upper Bound for L0 Recovery Performance of Binary Sparse Signals (이진 희소 신호의 L0 복원 성능에 대한 상한치)

  • Seong, Jin-Taek
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2018.05a
    • /
    • pp.485-486
    • /
    • 2018
  • In this paper, we consider a binary recovery framework of the Compressed Sensing (CS) problem. We derive an upper bound for $L_0$ recovery performance of a binary sparse signal in terms of the dimension N and sparsity K of signals, the number of measurements M. We show that the upper bound obtained from this work goes to the limit bound when the sensing matrix sufficiently become dense. In addition, for perfect recovery performance, if the signals are very sparse, the sensing matrices required for $L_0$ recovery are little more dense.

  • PDF

Safety Analysis of Storm Sewer Using Probability of Failure and Multiple Failure Mode (파괴확률과 다중파괴유형을 이용한 우수관의 안전성 분석)

  • Kwon, Hyuk-Jae;Lee, Cheol-Eung
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.11
    • /
    • pp.967-976
    • /
    • 2010
  • AFDA (Approximate Full Distribution Approach) model of FORM (First-Order Reliability Model) which can quantitatively calculate the probability that storm sewer reach to performance limit state was developed in this study. It was defined as a failure if amount of inflow exceed the capacity of storm sewer. Manning's equation and rational equation were used to determine the capacity and inflow of reliability function. Furthermore, statistical characteristics and distribution for the random variables were analyzed as a reliability analysis. It was found that the statistical distribution for annual maximum rainfall intensity of 10 cities in Korea is matched well with Gumbel distribution. Reliability model developed in this study was applied to Y shaped storm sewer system to calculate the probability that storm sewer may exceed the performance limit state. Probability of failure according to diameter was calculated using Manning's equation. Especially, probability of failure of storm sewer in Mungyeong and Daejeon was calculated using rainfall intensity of 50-year return period. It was found that probability of failure can be significantly increased if diameter is decreased below the original diameter. Therefore, cleaning the debris in sewer pipes to maintain the original pipe diameter should be one of the best ways to reduce the probability of failure of storm sewer. In sewer system, two sewer pipes can flow into one sewer pipe. For this case, probability of system failure was calculated using multiple failure mode. Reliability model developed in this study can be applied to design, maintenance, management, and control of storm sewer system.

Statistical Design of X Control Chart with Improved 2-of-3 Main and Supplementary Runs Rules (개선된 3 중 2 주 및 보조 런 규칙을 가진 X관리도의 통계적 설계)

  • Park, Jin-Young;Seo, Sun-Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.4
    • /
    • pp.467-480
    • /
    • 2012
  • Purpose: This paper introduces new 2-of-3 main and supplementary runs rules to increase the performance of the classical $\bar{X}$ control chart for detecting small process shifts. Methods: The proposed runs rules are compared with other competitive runs rules by numerical experiments. Nonlinear optimization problem to minimize the out-of-control ARL at a specified shift of process mean for determining action and warning limits at a time is formulated and a procedure to find two limits is illustrated with a numerical example. Results: The proposed 2-of-3 main and supplementary runs rules demonstrate an improved performance over other runs rules in detecting a sudden shift of process mean by simultaneous changes of mean and standard deviation. Conclusion: To increase the performance in the detection of small to moderate shifts, the proposed runs rules will be used with $\bar{X}$ control charts.

Thermal Performance of a Small-scale Loop Heat Pipe for Terrestrial Application (지상용 소형 루프히트파이프 성능에 관한 연구)

  • Chung, Won-Bok;Boo, Joon-Hong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1052-1057
    • /
    • 2004
  • A small-scale loop heat pipe with polypropylene wick was fabricated and tested for its thermal performance. The container and tubing of the system was made of stainless steel and several working fluids were used to see the difference in performance including methanol, ethanol, acetone, R134a, and water. The heating area was 35 mm ${\times}$ 35 mm and there were nine axial grooves in the evaporator to provide a vapor passage. The pore size of the polypropylene wick inside the evaporator was varied from 0.5 m to 25 m. The size of condenser was 40 mm (W) ${\times}$ 50 mm (L) in which ten coolant paths were provided. The inner diameter of liquid and vapor transport lines were 2.0 mm and 4.0 mm, respectively and the length of which were 0.5 m. The PP wick LHP was operated with methanol, acetone, and ethanol normally. R134a was not compatible with PP wick and water was unsuitable within operating limit of $100^{\circ}C$. The minimum thermal load of 10 W (0.8 W/cm2) and maximum thermal load of 80 W (6.5 W/cm2) were achieved using methanol as working fluid with the condenser temperature of $20^{\circ}C$ with horizontal position.

  • PDF

Calibration System Suitability Evaluation and Test Limits Determination Method through Factor Analysis of Uncertainty (불확도 요인 분석을 통한 교정 시스템 적합성 평가 및 시험기준 결정 방안)

  • Kim, Hong-Tark;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1139-1144
    • /
    • 2019
  • A calibration system for diagnosing and confirming the performance of precision measuring instruments minimizes the risk of misjudgment of calibration resulted by complying with international standard requirements in order to ensure the reliability of calibration results. This paper uses a proposed calibration system suitability assessment and a guard-band technique through an analysis of uncertainty factors when it is impossible to acquire and operate high-performance equipment at a calibration laboratory, and proposes an optimized test limit output model substituting performance standards. The proposed method provides an optimized test standard to meet the quantitative evaluation criteria of the calibration system and the probability of false acceptance risk required by international standards.

Improvement of aseismic performance of a PGSFR PHTS pump

  • Lee, Seong Hyeon;Lee, Jae Han;Kim, Sung Kyun;Kim, Jong Bum;Kim, Tae Wan
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1847-1861
    • /
    • 2020
  • A design study was performed to improve the limit aseismic performance (LSP) of a primary heat transport system (PHTS) pump. This pump is part of the primary equipment of a prototype generation IV sodium-cooled fast reactor (PGSFR). The LSP is the maximum allowable seismic load that still ensures structural integrity. To calculate the LSP of the PHTS pump, a structural analysis model of the pump was developed and its dynamic characteristics were obtained by modal analysis. The floor response spectrum (FRS) initiated from a safety shutdown earthquake (SSE), 0.3 g, was applied to the support points of the PHTS pump, and then the seismic induced stresses were calculated. The structural integrity was evaluated according to the ASME code, and the LSP of the PHTS pump was calculated from the evaluation results. Based on the results of the modal analysis and LSP of the PHTS pump, design parameters affecting the LSP were selected. Then, ways to improve the LSP were proposed from sensitivity analysis of the selected design variables.

Analysis of DA-6034, a New Flavonoid Derivative in Biological Fluids by HPLC (HPLC를 이용한 생체 시료중의 새로운 플라보노이드 유도체인 DA-6034의 분석)

  • Lee, Jong-Jin;Son, Mi-Won;Yoo, Moo-Hi;Jang, Min-Sun;Kim, Won-Bae;Lee, Kang-Chun
    • YAKHAK HOEJI
    • /
    • v.42 no.2
    • /
    • pp.149-152
    • /
    • 1998
  • A high performance liquid chromatographic method was developed for the determination of DA-6034 in biological fluids using internal standard. Plasma containing DA-6034 and inter nal standard was extracted by liquid-liquid extraction at an acidic pH. After evaporation of the organic layer, the drug and internal standard were reconstituted with mobile phase and injected into the column. They were separated by high performance liquid chromatography on inertsil ODS II column at 334 nm. The detection limit of DA-6034 in plasma was 0.02 ${\mu}$g/ml. In this method, the range of recovery and coefficients of variation were 96-110% and 0.40-3.78%, respectively. There was no interference from endogenous substances. Urine and bile were analysed using the deproteinization method and the detection limit of DA-6034 was 1${\mu}$g/l.

  • PDF