• Title/Summary/Keyword: Performance inspection devices

Search Result 86, Processing Time 0.031 seconds

Development on the Process Control System for Full Gate Visual Test of LCD Manufacturing Process (LCD 생산공정의 전게이트 시각 검사를 위한 공정 제어장치 개발)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1725-1728
    • /
    • 2009
  • This research developed process control device and FGV pattern generating device essential for full gate visual inspection to improve process so that defect detection capability may be maximized in specified environment. The devices developed in this research, which can be swiftly replaced in case loss or error occurs, are anticipated to improve module yield as well as maintain tact loss near '0'. In addition, as a result of mounting H/W and S/W system to control detailed operation sequence in production line and executing performance check and verification, detection rates were 98.1% and 99.1% respectively for pixel defect by tact and line defect, and yield of the entire module process including gate and visual level test increased up to 98.3%.

Cost-Benefit Analysis Method for Ageing Equipment of Chemical Plants Using Risk Assessment (위험성평가를 이용한 노후설비에 대한 비용 편익분석 방법)

  • Jung, Soomin;Jung, Changmo;Kang, Seok-Min;Chae, Seungbeen;Kang, Seung-Gyun;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.84-92
    • /
    • 2020
  • Most facilities in chemical plants operate in environments that are outside the range of temperature and pressure that can be encountered on a daily basis, and are vulnerable to aging due to these stresses and environmental conditions. The facilities exposed to these conditions are not only likely to fail due to cumulative damage, but also lead to accidents if maintenance and replacement are not performed.Recommendation guidelines called risk-based inspection are widely used around the world-wide. However, limits exist for facilities that have already elapsed for a certain. As a result of the survey on the aging of Ulsan industrial complex in Korea, which carries out proper inspection, many of the facilities have been used for 20 years. Also, most of the facilities where the accident occurred have been in operation for more than 20 years. Therefore, this study suggested criteria for classifying devices that have exceeded a certain period of use as obsolete facilities. In addition, quantitative risk assessment was conducted. The safety investment method using the cost-benefit analysis method was proposed in order to calculate the loss cost and reduce the risk by expressing the risks of the corresponding aged facility as an Economic index. By utilizing the method of cost-benefit analysis of old facilities using the quantitative risk assessment presented in this study, it can be expected to improve the performance and life of old facilities, improve production efficiency and reliability of the system of facilities, change the recognition of safety management costs, increase employee stability, and reduce loss costs.

Study on an Evaluation of Remote Control Torch Performance to reduce CO2 Welding Defects (CO2 용접결함 감소를 위한 원격 제어 토치 성능 평가 연구)

  • Kim, Jeong-Hyeok;Oh, Seck-Hyeog;Lee, Hae-Gil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6282-6288
    • /
    • 2014
  • $CO_2$ welding is used widely in the field. On the other hand, welding defects occur when welders cannot adjust the current and voltage needed for welding and have to stop working to adjust the current and voltage, causing sudden cooling down of the welding structure inside a vehicle or tank where the control panel is invisible or when work site is far. This study used three types of existing $CO_2$ welders. This also applied SS400 rolled steel for welding structural purposes for remote control torch welding, perform a welding test through v-groove butt welding with a remote control torch and existing $CO_2$ welding torch, conducted visual inspection on the appearance of a welded top bead. In addition, the appearance quality of the welding part was monitored mainly through penetrant testing and a bending test to evaluate the welding defect reduction and the effect on the performance and compatibility by replacing the existing welder.

Training Feedback effect of team-based CPR using a mobile video recording device body camera (이동용 영상촬영기기 바디캠을 활용한 팀단위 심폐소생술의 교육피드백 효과)

  • Seong bin Im
    • Smart Media Journal
    • /
    • v.13 no.5
    • /
    • pp.62-71
    • /
    • 2024
  • This study conducted a team-based CPR simulation with 32 fourth-year emergency rescue students to determine the effectiveness of training feedback using body cameras used at emergency rescue sites, and measured awareness, training feedback effectiveness, and satisfactio+n before and after body camera feedback. , preferences and difficulties in using body camera devices were identified. Data analysis was performed using SPSS 27.0 program, including descriptive statistics, frequency analysis, paried t-test, and Wilcoxon signed rank test. As a result of the study, the perception of body camera use showed a positive change from 3.73±0.62 points to 4.45±0.54 points, and a positive satisfaction level of 3.98±0.51 was shown (p<.001). Additionally, there was a significant increase in self-check accuracy and performance score after body camera feedback (p<.001). Therefore, during team-based simulation resuscitation training, positive feedback effects in improving self-inspection ability and performance can be achieved by watching body camera videos and using self-checklists without direct feedback from the instructor.

Inspection on the acoustic output of the focused extracorporeal focused shock wave therapeutic devices approved by MFDS (식약처에서 허가된 집속형 ESWT 치료기의 음향 출력 분석)

  • Choi, Min Joo;Jeon, Sung Joung;Kwon, Oh Bin;Lee, Min Young;Cho, Jin Sik;Kim, Han Soo;Maeng, Eun Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.303-317
    • /
    • 2020
  • Extracorporeal Shock Wave Therapy (ESWT) is an innovative treatment in chronic musculoskeletal pain management and cardiovascular diseases. In this study, we surveyed the acoustic shock wave outputs from the domestically used focal type ESWT devices. The survey data were collected through 30 technical documents registered to the Ministry of Food and Drug Safety (MFDS), Rep. Korea. The results show that the focusing geometry varies largely, 5 mm to 65 mm in the focal length, 3 mm to 30 mm in focal width, and 4 mm to 108 mm in focal depth. The maximum positive pressure (P+) ranges from 7 MPa to 280 MPa, the focal Energy Flux Density (EFD) from 0.0035 mJ/㎟ to 35 mJ/㎟, and the energy per pulse (E) from 0.737 mJ to 80.86 mJ. All domestic PE-type (five) and one EM-type domestic devices included in the analysis of the correlation between P+ and EFD are shown to be far beyond the usual ranges and do not comply with expected correlation so that the reliability of their data was suspected. For the suspected, post-performance tests are required by a recognized testing agency. MFDS guidelines need to be revised so that the pass criteria for the shock wave acoustic outputs can be based on the clinical tests for indications.

Design and Implementation of a Physical Network Separation System using Virtual Desktop Service based on I/O Virtualization (입출력 가상화 기반 가상 데스크탑 서비스를 이용한 물리적 네트워크 망분리 시스템 설계 및 구현)

  • Kim, Sunwook;Kim, Seongwoon;Kim, Hakyoung;Chung, Seongkwon;Lee, Sookyoung
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.7
    • /
    • pp.506-511
    • /
    • 2015
  • IOV is a technology that supports one or more virtual desktops, and can share a single physical device. In general, the virtual desktop uses the virtual IO devices which are provided by virtualization SW, using SW emulation technology. Virtual desktops that use the IO devices based on SW emulation have a problem in which service quality and performance are declining. Also, they cannot support the high-end application operations such as 3D-based CAD and game applications. In this paper, we propose a physical network separation system using Virtual Desktop Service based on HW direct assignments to overcome these problems. The proposed system provides independent desktops that are used to access the intranet or internet using server virtualization technology in a physical desktop computer for the user. In addition, this system can also support a network separation without network performance degradation caused by inspection of the network packet for logical network separations and additional installations of the desktop for physical network separations.

Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography (유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석)

  • Jung, Hong-Ryang;Hong, Dong-Hee;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant, manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration "about the safety of diagnostic radiation generator rule" specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

Piezoelectric nanocomposite sensors assembled using zinc oxide nanoparticles and poly(vinylidene fluoride)

  • Dodds, John S.;Meyers, Frederick N.;Loh, Kenneth J.
    • Smart Structures and Systems
    • /
    • v.12 no.1
    • /
    • pp.55-71
    • /
    • 2013
  • Structural health monitoring (SHM) is vital for detecting the onset of damage and for preventing catastrophic failure of civil infrastructure systems. In particular, piezoelectric transducers have the ability to excite and actively interrogate structures (e.g., using surface waves) while measuring their response for sensing and damage detection. In fact, piezoelectric transducers such as lead zirconate titanate (PZT) and poly(vinylidene fluoride) (PVDF) have been used for various laboratory/field tests and possess significant advantages as compared to visual inspection and vibration-based methods, to name a few. However, PZTs are inherently brittle, and PVDF films do not possess high piezoelectricity, thereby limiting each of these devices to certain specific applications. The objective of this study is to design, characterize, and validate piezoelectric nanocomposites consisting of zinc oxide (ZnO) nanoparticles assembled in a PVDF copolymer matrix for sensing and SHM applications. These films provide greater mechanical flexibility as compared to PZTs, yet possess enhanced piezoelectricity as compared to pristine PVDF copolymers. This study started with spin coating dispersed ZnO- and PVDF-TrFE-based solutions to fabricate the piezoelectric nanocomposites. The concentration of ZnO nanoparticles was varied from 0 to 20 wt.% (in 5 % increments) to determine their influence on bulk film piezoelectricity. Second, their electric polarization responses were obtained for quantifying thin film remnant polarization, which is directly correlated to piezoelectricity. Based on these results, the films were poled (at 50 $MV-m^{-1}$) to permanently align their electrical domains and to enhance their bulk film piezoelectricity. Then, a series of hammer impact tests were conducted, and the voltage generated by poled ZnO-based thin films was compared to commercially poled PVDF copolymer thin films. The hammer impact tests showed comparable results between the prototype and commercial samples, and increasing ZnO content provided enhanced piezoelectric performance. Lastly, the films were further validated for sensing using different energy levels of hammer impact, different distances between the impact locations and the film electrodes, and cantilever free vibration testing for dynamic strain sensing.

Surface Measurement of Microstructures Using Optical Pick-up Based Scanner (광픽업 스캔 장치를 이용한 미소 구조물의 표면 측정)

  • Kim, Jae-Hyun;Park, Jung-Yul;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.73-76
    • /
    • 2010
  • The issue of inspection and characterization of microstructures has emerged as a major consideration in design, fabrication, and detection of MEMS devices. However, the conventional measurement techniques, including scanning electron microscopy (SEM) imaging, atomic force microscopy (AFM) scanning, and mechanical surface profiler, require often destructive process or may be difficult to measure with a wafer scale. In this paper, we characterize the surface profiles of microstructures using an optical scanner based on a DVD pick-up module. Scanning images of the microstructures are successfully generated using the intensity of reflected light from different depths of the surface profiles, based on the focus error signal (FES) from photodiodes. It is shown that the proposed optical scanner can be used as an alternative measurement system with high performance and low cost, compared to conventional measurement techniques.

Automatic Noncontact Ultrasonic Inspection Technique (비접촉식 초음파탐상방법 자동화 기술)

  • Kim, Y.G.;Ahn, B.Y.;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.4
    • /
    • pp.25-31
    • /
    • 1994
  • A system for EMAT, which generates ultrasound by electro-magnectic forces and performs nondestructive testing in noncontact, was established. By linking it with a 3 axis scanning system and a data acquisition and processing system the automation of EMAT testing was attempted. A EMAT sensor was fabricated and the directivity pattern of it was measured. To be suitable automation, it has a transmitter and a receiver in one case and the main beam direction of it can be controlled by the frequency of driving signal. A program which controls the EMAT system, the 3 axis scanner and the data acquisition and processing system was developed. It also processes acquired data and displays the processing results. IBM-PC/AT compatible PC was used as main controller and the stratage of the program is emulation of real devices on the PC monitor. To provide the performance of the established EMAT system, two aluminium blocks containing artificial flaws and a welded aluminium block were tested. The result of the tests were satisfactory.

  • PDF