• Title/Summary/Keyword: Performance experiment

Search Result 8,981, Processing Time 0.045 seconds

Validity Analysis of Scale Model Experiment for Wetting Agent Performance Evaluation (침윤소화약제 성능평가를 위한 축소실험의 타당성 분석)

  • Kim, Nam-Kyun;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.14-19
    • /
    • 2014
  • A current standard exist only on the surface tension in the current domestic wetting agent technology standards, so it is difficult to the performance evaluation of the wetting agent through the standard. So this study presents the optimized performance evaluation methods by scale model experimental equipment in order to present techniques for performance evaluation of wetting agents. The purpose of this study is to investigate validity of experimental results of the self-designed scale model experiment equipment by a comparative analysis of experimental results of the NFPA 18 experiment and the experiment using the self-designed scale model experiment equipment. As a result of a comparative analysis of experimental results of the NFPA 18 experiment that evaluate only the permeation performance on the contton and the experiment using the self-designed scale model experiment equipment that evaluate the permeation performance and fire extinguishing performance on wood flour, the discrimination of the permeation performance was confirmed in both the NFPA 18 experiment and the self-designed scale model experiment equipment. And a result of self-designed experiment equipment have clear discriminatory more than NFPA 18 by internal temperature measurement using the thermocouples.

Classification of Noise Insulation Performance in Apartment Buildings through Noise survey and Auditory Experiment (설문조사와 청감실험을 통한 공동주택 차음성능의 평가등급 설정)

  • Ryu, Jong-Kwan;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.666-669
    • /
    • 2005
  • Social noise survey and auditory experiment on residential noises such as floor impact, air-borne, bathroom, drainage and traffic noises were conducted to classily a noise insulation Performance in apartment building. The survey results showed that annoyance among subjective responses to residential noises was most greatly affecting to satisfaction with noises. In the survey, boundary limit between satisfaction and dissatisfaction was also determined. Auditory experiments was also undertaken to determine noise insulation performance according to the percent of satisfaction for individual noise source. Result of auditory experiment showed that the noise insulation performance for floor impact, airborne, drainage and traffic noise corresponding to 40 % satisfaction is 49 dB (L$_{i,Fmax,AW}$), 48 dB (R'w), N-41, and N-40, respectively. Finally, classes of noise insulation performance in apartment building were proposed according to satisfaction with noises

  • PDF

Optimal Performance Design for Concrete Median Barrier with Crashworthiness Analysis (차량 충돌 해석을 통한 중앙분리대의 최적 성능 설계)

  • 한석영;고성호;최형연
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.168-178
    • /
    • 2002
  • The purpose of this study is to develop an optimal performance design ova concrete median barrier using the design of experiment and crash simulation which is done by Pam-Crash, one of the commercial crash simulation software. A formula of characteristic value was suggested to obtain an optimal performance design considering all of von Mises stress, volume and acceleration at center of gravity of a heavy truck. An optimal design of a concrete median barrier was obtained by the analysis of variance based on design of experiment and crash simulation. A crash simulation with the optimal design was accomplished in order to verify the suitability of the suggested formula and the proper application of the design of experiment. The obtained optimal design was satisfied for a domestic design regulation of a concrete median barrier.

Performance Evaluation of Ground Source Heat Pump System Utilizing Energy Pile in Apartment (공동주택에서 에너지 파일을 이용한 지열히트펌프 시스템의 성능 분석)

  • Lee, Jin-Uk;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.41-46
    • /
    • 2012
  • In Korea, Apartment houses recently occupy over 80% of all buildings. Ground source system has to be designed to consider feature of apartment house. Most apartment houses use PHC pile to get a bearing power of the soil. Therefore, the purpose of this study is to evaluate performance of ground source heat pump system utilizing energy pile under apartment. Object of experiment is low-energy experiment apartment in Song-do and Energy Pile are applied to 80%, 100% energy reduction model for heat-source. First, performance evaluation of Energy Pile geothermal system was done during summer season. As a result, The COP(coefficient of performance) about geothermal heatpump was approximately 5-6 while cooling. In winter season, Long experiment was performed because it was very important to evaluate ground condition for long time. During heating experiment, Indoor room set temperature was $20^{\circ}C$ and kept constant by heating. Coefficient of performance for heat pump and overall system was calculated. It was 3.5-4.5 for COP and 2.5-3.7 for system COP.

Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model (실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석)

  • Baik, Seung Heon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

The Analysis of Elementary Pre-service Teachers' Reflective Thinking and Experiment Performance Ability on Photosynthesis Experiment (광합성 실험에서 나타난 초등 예비교사들의 반성적 사고와 실험 수행 능력 분석)

  • Kim, Dong-Ryeul
    • Journal of Korean Elementary Science Education
    • /
    • v.34 no.4
    • /
    • pp.502-518
    • /
    • 2015
  • In order to find out Elementary pre-service teachers' reflective thinking and experiment performance ability related with Photosynthesis Experiment in the Korea Elementary School Science Textbook, the research is conducted targeting Elementary pre-service teachers. They are asked to carry out the experiment and write their own report about the difficulties and solutions of exploration process. This study aims to analyze Elementary pre-service teachers' reflection and experiment performance ability on Photosynthesis experiment based on 10 groups' reports and presentation materials. Reflective thinking extracts 108 statements which is associated with the four types of the sentence 'Knowledge, Procedure, Orientation, Attitude' in 10 reports. There are many sentences about reflective thinking acquired through analysis of the photosynthesis experiment. reflective thinking about the newly discovered type or changed concepts through experimentation in Knowledge is at the highest frequency. 56 sentences in relation to the ability to perform experiments are extracted by adding 4 different types of reflective thinking in 10 groups shown the highest frequency group and the lowest frequency group's report through analyzing 4 steps 'Experimental preparation and safety accident prevention', 'Experiments performance', 'Experimental results and generalization', and 'Experimental results and feedback.' Results of the analysis showed that there are the biggest difference between the two groups in 'experiment results supplement and feedback step.' In the lowest group's report, there's no contents related with 'Computer-assisted information processing' in the 'Experimental results summary and generalization stage', 'Alternative reagents and materials research', and 'Devising alternative experiment methods'.

Visual Performance Evaluation of Daylighting System with Sloped Lightshelves (광선반 채광시스템의 시각적 성능 평가)

  • Kim, Jeong-Tai;Shim, In Bo
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.3-10
    • /
    • 2006
  • This study assessed the visual performance of luminous environment by the lightshelf. The subject survey method was used and results are presented and analyzed. The lightshelf daylighting system was developed by LAEL at KH University and was applied on the window of a mock-up office. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. The experiment was conducted during the bright part of the day from noon to one thirty on June 7, 2006. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. During the experiment was carrying out, the work plane illuminance and luminous distribution at surrounding the windows was measured. The semantic differential rating data of experiment were analyzed by t-test and factor analysis using SPSS 12.0 statistics package. The visual performance of the lightshelf was more positive. The factors affecting the visual performance are task performance and visual comfort. The subjects were more comfortable in a room installed with lightshelves on both the task performance and the visual comfort aspect. Therefore, the application of sloped lightshelf daylighting system improves visual performance of luminous environment.

TV용 패널 검사대 최적조명설계에 관한 연구

  • 조항준;김성환;정의승
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.3-14
    • /
    • 1995
  • To investigate the effect of illumination conditions on visual inspection performance for TV panel glasses, three dependent variables, inspection time, error, and preference , were measured and analyzed through two consecutive experiments. The first experiment for reflection inspection was conducted using two independent variables, position and brightness. The second experiment for transparent inspection was made using two independent variables, height and brightness. The summary of the results of the experiment for reflection inspection are as follows ; The inspection performance of the position right above the subject (Position 1) was the best among the conditions in terms of errors, while the performance of the position slightly in front of and above the subject(Position 2) was the best in terms of inspection times. Inspection time was statistically different according to the brightness conditions specifically at the position in front of the subject(Position 3). The results of the second experimen for transparent inspection are that the inspection performance at medium height (Height 2) was the best among the three conditions in terms of errors while the performance at lower height(Height 3) was the best in subject preference. Based upon both results with respect to actual field conditions, two alternative inspection station designs were proposed for each lighting conditon.

  • PDF

Growth performance and nutrient digestibility of growing-finishing pigs under different energy concentrations

  • Park, Sangwoo;Kang, Joowon;Lee, Jeong Jae;Kyoung, Hyunjin;Kim, Seong-Ki;Choe, Jeehwan;Song, Minho;Lee, Soo Kee
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.2
    • /
    • pp.275-282
    • /
    • 2020
  • Two experiments were conducted to examine the effects of the difference in energy concentration in diets on performance and nutrient digestibility of growing-finishing pigs. The experimental diets were as follows: 1) a normal energy level corn-soybean meal-based diet (CON) and 2) high-energy diet compared with the CON (HE). Pigs had free access to their feed and water ad labium for 6 weeks during each experimental period. In experiment 1, 60 growing pigs (initial body weight [BW] of 23.85 kg) were randomly allotted to 2 treatment groups with 5 replications (6 pigs·pen-1). In experiment 2, 48 finishing pigs (initial BW = 65.13 kg) were randomly assigned to 2 treatment groups with 6 replications (4 pigs·pen-1). The growth performance was measured at the beginning and end of each period. The apparent total tract digestibility (ATTD) was determined by chromium oxide as an indigestible marker during the last 7 days of each experiment. In experiment 1, the dietary treatments did not affect the growth performance and ATTD of energy and nutrients. In experiment 2, no differences in growth performance were observed for pigs fed CON and HE throughout the experimental period. Additionally, dietary treatments did not affect the ATTD. In conclusion, the high energy content in diets for the growing-finishing period had no effect on the growth performance or digestibility, indicating that a wide range of energy content changes in diets would be required to affect the performance and digestibility of grower-finisher pigs. It is also necessary to understand the characteristics of components used to adjust the dietary energy concentration.

Heating Performance Analysis of Building Integrated Geothermal System (건물일체형 지열히트펌프시스템의 난방 성능 분석)

  • Jin, Shangzhen;Lee, Jin-Uk;Kim, Tae-Yeon;Leigh, Seung-Bok
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.206-210
    • /
    • 2012
  • Ground source heat pump is a central heating and cooling system that pumps heat to or from the ground. Building Integrated Geothermal system used in this experiment is one of the Ground Source Heat Pump Systems which utilize energy pile. The purpose of this study is to evaluate heating performance of the system. The building is a low-energy experiment apartment in Yonsei University Songdo Campus and the subject is one of the energy reduced houses in this apartment. In the experiment, indoor temperature, outdoor temperature and the inlet and outlet temperature of ground heat exchanger and subject model, were measured. Then the heat pump's Coefficient of performance(COP) of the heat pump was calculated. As a result, the COP of heat pump is 4-5. Although the depth of the ground heat exchanger in this experiment is shallower than usual heat exchanger, the result of heating performance of this system was good as well.

  • PDF