• Title/Summary/Keyword: Performance evaluation test

Search Result 3,858, Processing Time 0.038 seconds

Seismic Stability and Fatigue Performance Test of Lead Rubber Bearings (납-적층고무받침의 지진안정성 및 피로거동 실험)

  • Cho, Chang-Beck;Kwahk, Im-Jong;Kim, Young-Jin;Kwark, Jong-Won;Cho, Hae-Jin
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.537-544
    • /
    • 2006
  • In this study, performance level evaluation tests have been actually performed on laminated rubber seismic isolation bearings (LRB) made in Korea. To provide basic data for setting up fabrication criteria and performance evaluation criteria three real scale LRB were tested and the test results were analysised. Accordingly, a large capacity test device has been designed and manufactured to implement the tests. The device selected for evaluation is a circular LRB actually applied in bridges. Evaluation tests were conducted using full-scale LRB with diameter of 851mm in the rubber part and total height of 215mm of which the effective horizontal stiffness and equivalent damping ratio have been measured during the experiments.

  • PDF

A Study of Test and Evaluation Method for Performance Improvement of Air to Ground Communication Radios (공지통신무전기 성능개량을 위한 시험평가 방안 연구)

  • Lee, Byeongheon;Ahn, Seungbeom;Choi, Myungsuk;Hur, Jang-Wok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.267-274
    • /
    • 2022
  • The Republic of Korea has a close cooperative relationship with NATO, of which the United States is a member. NATO is encouraged to follow UHF coalition waveforms for military air operations(SATURN) as defined in STANAG 4372. SATURN is a high-speed frequency hopping waveform with enhanced anti-jamming and security functions. Plans to improve the performance of existing military aircraft with air to ground radios to which SATURN function is applied. IFF case analysis and MRT evaluation plan were established to present an efficient test and evaluation plan for air to ground radios.

Performance Evaluation of Wired/Wireless LAN Adaptors (유무선 LAN 어댑터의 성능시험)

  • 이부호
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.209-212
    • /
    • 2000
  • This paper discusses performance evaluation methodologies for wired/wireless Ethernet adaptors. This paper defines test cases for performance evaluation of LAN adaptor and its environments. Performance evaluation of LAN adaptor is mote complex as compared with interconnection devices such as Ethernet HUB and Ethernet switch, because its performance depends on the system on which the adaptor is plugged. Such dependencies include CUP type, RAM size, system bus architecture(PCI bus clock), etc.

  • PDF

A Study on the Performance Evaluation of Cook in Hotel Restaurant (호텔레스토랑 조리직무의 평가에 관한 연구)

  • 진양호
    • Culinary science and hospitality research
    • /
    • v.6 no.2
    • /
    • pp.5-21
    • /
    • 2000
  • The purpose of this study looks for the directions to improve the performance evaluation of cook by examining the perceptions for performance of cook by supervisors in hotel restaurant. In order for this purpose, this study focuss on two areas: (1) the significant differences of each hotel type on the perceptions of each performance evaluation item, (2) the significant differences of each kitchen type on the perceptions of each performance evaluation item in terms of two different types of hotel. To examine (1) and (2), this study uses Student t test and anova analysis. The findings from this study have both theoretical and practical implications. Implications of these findings are discussed.

  • PDF

Development of Anti-Spoofing Equipment Architecture and Performance Evaluation Test System

  • Jung, Junwoo;Park, Sungyeol;Hyun, Jongchul;Kang, Haengik;Song, Kiwon;Kim, Kapjin;Park, Youngbum
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.3
    • /
    • pp.127-138
    • /
    • 2018
  • Spoofing attacks including meaconing can provide a bogus position to a victim GPS receiver, and those attacks are notably difficult to detect at the point of view on the receiver. Several countermeasure techniques have been studied to detect, classify, and cancel the spoofing signals. Based on the countermeasure techniques, we have developed an anti-spoofing equipment that detects and mitigates or eliminates the spoofing signal based on raw measurements. Although many anti-spoofing techniques have been studied in the literatures, the evaluation test system is not deeply studied to evaluate the anti-spoofing equipment, which includes detection, mitigation, and elimination of spoofing signals. Each study only has a specific test method to verify its anti-spoofing technique. In this paper, we propose the performance evaluation test system that includes both spoofing signal injection system and its injection scenario with the constraints of stand-alone anti-spoofing techniques. The spoofing signal injection scenario is designed to drive a victim GPS receiver that moves to a designed position, where the mitigation and elimination based anti-spoofing algorithms can be successively evaluated. We evaluate the developed anti-spoofing equipment and a commercial GPS receiver using our proposed performance evaluation test system. Although the commercial one is affected by the test system and moves to the designed position, the anti-spoofing equipment mitigates and eliminates the injected spoofing signals as planned. We evaluate the performance of anti-spoofing equipment on the position error of the circular error probability, while injecting spoofing signals.

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash (수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰)

  • Lee, Kiyeon;Gil, Hyoungjun;Kim, Dongook;Kim, Dongwoo;Kang, Daechul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

Study on performance evaluation of a francis turbine (프란시스 수차의 성능평가에 관한 연구)

  • Ko, Jaemyoung;Kim, Youngjoon;Cho, Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.207.1-207.1
    • /
    • 2011
  • The performance of a francis turbine is studied by applying a new performance evaluation tester. the performance of a francis turbine is predicted under several operating conditions and the prediction results are compared with model test data. As a result, it is demonstrated that the present method can predict the performance of a francis turbine with high accuracy and has usefullness as an engineering tool on the performance of hydraulic turbines.

  • PDF

Design of Reliability Qualification Test Based on Performance Distribution at the Earlier Stage (초기 단계의 성능분포를 활용한 신뢰성 인증시험의 설계)

  • Jeong, Hai-Sung
    • Journal of Applied Reliability
    • /
    • v.12 no.3
    • /
    • pp.131-138
    • /
    • 2012
  • A design of reliability qualification test based on performance distribution is developed. In general, the performance of an item degrades as the time goes by and the failure of an item occurs when the performance degradation reaches the pre-determined critical level. This article considers the reliability qualification test based on a more tightened critical value at the earlier stage to reduce the evaluation testing time and cost. A numerical example is provided to illustrate how to use the developed reliability qualification test.

The Fatigue Performance Evaluation of Concrete Specimen by Using Mineral Admixture (혼화재 사용에 따른 콘크리트 시험체의 피로성능 평가)

  • Kim, Doo-Hwan;Baek, Kyung-Su
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.5
    • /
    • pp.39-43
    • /
    • 2010
  • The surfacing of bridge-decks are object to secure trafficability and to protect bridge face from impact load of traffic volume and other external conditions. But the deformation of pavements and cracks happen due to the damage of the bridge-decks surfacing from the increase of the traffic, short maintenance period and continuous vibration of bridge. This test is to make the 3-type high performance concrete that has different mixing ratio and is added the blast furnace slag, fly ash and silica respectively, and to compare 3-type high performance concrete of normal high strength concrete of $400kgf/cm^2$ strength through the static loading test and fatigue test. And test specimen is united floor slab and pavement for the durability of bridge.

A Draft Korean Standards on the Evaluation Method of Airborne Sound Insulation in Building and Building Elements (공기음 차단성능 평가방법의 KS규격화 방안)

  • 양관섭;이태강;이근희;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.387-391
    • /
    • 2001
  • In evaluating sound performance of building, it is important to carry on tests and evaluations based upon residential sound performances. Korean Standards include test methods on sound performance, but don't include any code on evaluation methods. Therefore, evaluation methods from Japan or ISO have been used for evaluating sound performance in domestic so far. In this study, a draft of Korean Standards on a sound performance evaluation method in buildings is proposed.

  • PDF