• Title/Summary/Keyword: Performance and Efficiency Drop

검색결과 263건 처리시간 0.025초

R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구 (A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant)

  • 정규하;박윤철;오상경
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.

포집량에 따른 p-DPF의 정화효율 및 BPT 특성에 관한 실험적 연구 (An Experimental Study on Filtration Efficiency and BPT Characteristics by PM Loading in Partial-diesel Particulate Filter)

  • 오광철;이경복;이춘범
    • 한국자동차공학회논문집
    • /
    • 제20권1호
    • /
    • pp.147-154
    • /
    • 2012
  • The number of vehicles applied diesel engine are rapidly rising for fuel economy. Accompanying this trend, application of an after-treatment system is strictly required as a result of reinforced emission regulation. The Diesel Particulate Filter (DPF) system is considered as the most efficiency method to reduce particulate matter (PM) by car makers but also in retrofit market. In recently, various kinds of partial flow DPF are widely used for proper filtration performance and reducing of pressure drop but it is difficult to define the characteristics of these filters because the filtration mechanism is obscure according to the status of these systems. In this paper we investigated the characteristics of cell open type DPF according to the status of filter especially, PM loading. The PM loading mass in the p-DPF are predicted from increase of differential pressure of DPF and the trend of filtration efficiency so that we can measure filtration efficiency and Balance Point Temperature (BPT) of this p-DPF according to PM loading.

프란시스수차의 수력학적 성능특성 분석 (Hydraulic Performance Analysis of Francis Type Turbine)

  • 이철형;박완순
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.664-667
    • /
    • 2009
  • The Francis type hydro turbine with vertical axis has been designed and analized for hydraulic performance verification. The guide vane angle of turbine casing were designed to be varied according to the condition of head and flowrate. When the changes in flowrate and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed hydro turbine in this study will be suitable for small hydro power stations with medium and high head such as agricultural reservoirs and large dam.

  • PDF

J-Groove Technique for Suppressing Various Anomalous Flow Phenomena in Turbomachines

  • Kurokawa, Junichi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.1-13
    • /
    • 2011
  • In operating a turbomachine at off-design conditions various instabilities caused by anomalous flow phenomena occur and sometimes lead to the damage of a turbomachine. In order to avoid these phenomena various devices characteristic to each phenomenon have been developed, however they make turbomachines large-sized and cause efficiency drop. The present author has developed a very simple and innovative device, termed "J-groove," of suppressing various anomalous flow phenomena commonly by controlling the angular momentum of the main flow. It has been revealed that J-groove makes an operation of a turbomachine stable in all flow range, causes little efficiency drop, and can be easily applied to an existing machine. Here is reviewed totally the results of suppressing various anomalous flow phenomena in turbomachines.

프란시스수차의 국산화 실증 연구 (Performance Verification of Francis Type Hydro Turbine for Domestic Production)

  • 이철형;박완순
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.167-171
    • /
    • 2008
  • The Francis type hydro turbine with vertical axis has been designed and analized for hydraulic performance verification. The guide vane angle of turbine casing were designed to be varied according to the condition of head and flowrate. When the changes in flowrate and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed hydro turbine in this study will be suitable for small hydro power stations with medium and high head such as agricultural reservoirs and large dam.

  • PDF

판형 열교환기의 열전달 및 압력강하 특성에 관한 연구 (A Study on Heat Transfer and Pressure drop Characteristics in Plate Heat Exchange)

  • 서무교;박재홍;김영수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.581-587
    • /
    • 2001
  • Plate heat exchange(PHE) will be applied to the refrigeration and air conditioning systems as evaporators or condensers for their high efficiency and compactness. The purpose of this study is the analyze the characteristics of heat transfer and pressure drop of plate heat exchanger. Numerical work was conducted using the FLUENT code k-$\varepsilon$model. Also the dependence of heat transfer coefficient and friction factor on Reynolds number was investigated. As the Reynolds number increases, it is found that heat transfer coefficient also increases, but friction factor decreases. The study examines the internal flow, thermal distribution and the pressure distribution in the channel of plate heat exchanger. The results of CFD analysis compared with experimental data, and the difference of friction factor and Nusselt number in plate heat exchanger are 10% and 20%, respectively, Therefore the CFD analysis model is effective for the performance prediction of plate heat exchanger.

  • PDF

A study on plasma-assisted patterning and doubly deposited cathode for improvement of AMOLED common electrode IR drop

  • Yang, Ji-Hoon;Kwak, Jeong-Hun;Lee, Chang-Hee;Hong, Yong-Taek
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.481-484
    • /
    • 2008
  • In order to reduce IR drop through common electrode in AMOLED, we propose a novel method to form electrical contact between highly-conductive bus lines and common electrode by using a plasma-assisted patterning of OLED layers and double deposition of the common electrode. Plasma-assisted patterning effects on OLED performance and degradation have been investigated. This patterning method caused turn-on voltage decrease, current flow increase at the same applied OLED voltages, quantum efficiency decrease, and rapid degradation at early stage during the lifetime test. However, comparable 70% luminance lifetime were obtained for both patterned and non-patterned OLEDs.

  • PDF

World's Largest 54-inch TFT-LCD for HDTV Application Using PVA Technology

  • Kim, K.H.;Seomun, S.S.;Chang, H.S.;Song, J.K.;Tak, Y.M.;Kim, S.S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.288-291
    • /
    • 2003
  • The technology and performance of the world-largest 54-inch LCD TV using PVA mode have been introduced from two points of view: one is to manufacture large-size panels, the other is to improve electro-optical performance required for multimedia applications. Current ongoing research activities that have been explored include new stitching design, one drop filling with column spacer, response time less than one frame rate, color performance and light efficiency enhancement.

  • PDF

카프란수차의 수력학적 성능특성 (Hydraulic Performance Characteristics of Kaplan Turbine)

  • 이철형;박완순
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.443-446
    • /
    • 2005
  • The Kaplan turbine model has been tested and analyzed. The blade angle and the guide vane opening of the turbine model were designed to be varied according to the best combination of guide vane and runner blade opening. When the changes in head and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load.

  • PDF

자동차용 정전 필터의 미세 입자 포집 특성 (Collection Performance of an Electret Cabin Air Filter for Fine Particles)

  • 지준호;강석훈;김동철;황정호;윤웅섭;배귀남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.85-90
    • /
    • 2001
  • This work presents experimental results of filter media test by using particles from $0.02\;to\;0.6{\mu}m$ in diameter and by applying different charging states. In order to investigate the electret filter performance, the collection efficiency and the pressure drop of filter were measured. The face velocities of test filters varied from 2.4 to 20.4 cm/s. Another experiment setup for the cartridge cabin air filter was used to get an collection efficiency in submicron region. After charging level of electret filter severely decreased, the change of collection efficiency was verified. Experimental results show that the reliability of electret filters can be poor in some conditions.

  • PDF