• Title/Summary/Keyword: Performance Standard

Search Result 7,013, Processing Time 0.033 seconds

An Investigation of ECDIS Type Approval based on International Standard (국제기준에 의한 ECDIS 인증방안 고찰)

  • 심우성;서상현
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.15-19
    • /
    • 2001
  • Electronic navigation system onboard have have been developed with recent technology based on new concept such as electronic chart date. The most valuable system of revolution in electronic navigation equipment is ECDIS, which have been developed in order to reduce work load of mariner and give an integrated information by simple means, especially to improve the safety of ship's navigation. In order to be sure the function of ECDIS is satisfied, The international standard have regulated the performance in the standard, so ECDIS should be type approved by the marine equipment authority of each government. There are three basic documents, IEC61174, IEC61162, IEC60945 issued by IMO(International Maritime Organization) which should be used for type approval system of each authority. IEC 61174 include the method of test and required results for operational and functional performance of test equipment. IEC61162 is for sensor interface and IEC60945 is related to the test of environmental condition for general marine radiocommunication equipment. In this paper, we investigate international standard in detail and current approval system of general marine equipment. After that, we present the possible structure of type approval of ECDIS and important considerations of approval system such that ECDIS should be tested as one system not be separated between S/W and H/W.

  • PDF

Energy Performance Evaluation of A Primary School Building for Zero Energy School (제로에너지 스쿨을 위한 초등 교육시설의 에너지 성능평가)

  • Yoon, Jong-Ho;Shin, U-Cheul;Cho, Jin-Il;Park, Jae-Wan;Kim, Hyo-Jung;Lee, Chul-Sung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.121-126
    • /
    • 2009
  • This study analyzed the standard school's energy usage and patterns as the zero-energy goal of primary school building, and proposed the energy reduction process of school building using energy analysis computing simulation tool. As a analysis simulation tool, Visual DOE 4.0 is used. For analysis of actual energy usage, selected primary school that is standard in the nation's energy consumption. Standard of the school's energy consumption analysis were devided into electric and gas energy. Input parameters of the simulation program based on the literature material and field survey material. after, but it was calibrated to comparison with the standard school's energy consumption. Finally, its energy usage analyzed by component and made the priority order of energy saving. Applied energy saving technologies are envelopment insulation, high efficiency lighting, high performance HAVC system and used active equipment system of solar collector and photovoltaic generation for additional savings.

  • PDF

Implementation of Dual-Kernel based Control System and Evaluation of Real-time Control Performance for Intelligent Robots (지능형 로봇을 위한 이중 커널 구조의 제어 시스템 구현 및 실시간 제어 성능 분석)

  • Park, Jeong-Ho;Yi, Soo-Yeong;Choi, Byoung-Wook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1117-1123
    • /
    • 2008
  • This paper implements dual-kernel system using standard Linux and real-time embedded Linux for the real-time control of intelligent robot systems. Such system provides more useful services including standard Linux thread that is easy to implement complicated tasks and real-time tasks for the deterministic response to velocity control. Here, an open source real-time embedded Linux, XENOMAI, is ported on embedded target board. And for interfacing with motor controller we adopted a real-time serial device driver. The real-time task was implemented with a priority to keep the cyclic control command for trajectory control. In order to validate deterministic response of the proposed system, the performance measurement of the delay in performing trajectory control with feedback loop is evaluated with non real-time standard Linux. The proposed software architecture is anticipated to take advantage of features in both standard Linux and real-time operating systems for the intelligent robot systems.

Advanced Receiver for Interference Cancellation in 3GPP LTE-A (3GPP LTE-A에서의 진화된 간섭 제거 수신기)

  • Hwang, Jin-Yup;Lee, Sang-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.7
    • /
    • pp.389-397
    • /
    • 2014
  • This paper focuses on advanced receiver for interference suppression or cancellation from neighbor cells in the 3GPP Rel-12 standard. From UE (User Equipment) perspective, the advanced receiver which can manage inter-cell interference of adjacent cell is required to support and manage fast-growing wireless data traffic. In 3GPP standard, NAICS which is one of approaches to improve SINR and receiver performance by directly suppression or cancellation of data (PDSCH) and control (PDCCH) signal from interference cells is discussed. In this paper, we briefly introduce the concept and candidate receivers for NAICS (Network Assisted Interference Cancellation and Suppression) based on 3GPP Rel-12 standard, and simulation results for basic NAICS receiver performance are provided.

Analytical Study of the Impact of the Mobility Node on the Multi-channel MAC Coordination Scheme of the IEEE 1609.4 Standard

  • Perdana, Doan;Cheng, Ray-Guang;Sari, Riri Fitri
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.1
    • /
    • pp.61-77
    • /
    • 2017
  • The most challenging issues in the multi-channel MAC of the IEEE 1609.4 standard is how to handle the dynamic vehicular traffic condition with a high mobility, dynamic topology, and a trajectory change. Therefore, dynamic channel coordination schemes between CCH and SCH are required to provide the proper bandwidth for CCH/SCH intervals and to improve the quality of service (QoS). In this paper, we use a Markov model to optimize the interval based on the dynamic vehicular traffic condition with high mobility nodes in the multi-channel MAC of the IEEE 1609.4 standard. We evaluate the performance of the three-dimensional Markov chain based on the Poisson distribution for the node distribution and velocity. We also evaluate the additive white Gaussian noise (AWGN) effect for the multi-channel MAC coordination scheme of the IEEE 1609.4 standard. The result of simulation proves that the performance of the dynamic channel coordination scheme is affected by the high node mobility and the AWGN. In this research, we evaluate the model analytically for the average delay on CCHs and SCHs and also the saturated throughput on SCHs.

Evaluation of the Residual Performance of Partially Charred Components of Old Wooden Structure I - Use of Ultrasonic Velocity and Testing of the Drilling Resistance -

  • Lee, Hyun-Mi;Hwang, Won-Joung;Lee, Dong-Heub;Kim, Hong Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.193-206
    • /
    • 2014
  • Residual performance of old architectural wood which has been damaged was measured using Nondestructive Evaluation (NDE). The wood Pole Tester was used to assess ultrasonic velocity inside wood and drill resistance was determined using an IML-resistograph. For ultrasonic measurements squared timber and circular timber's measurements were separately conducted with 1,300 m/s as the standard ultrasonic velocity. The standard wood samples divided into two parts; a non-sound area (below the standard), and a sound area (above the standard). Furthermore, schematization of wood was compared with results naked eye observation. The drilling resistance test was performed for both length and thickness direction in wood. The internal of the drilling was set at 30 cm (length direction), 5 cm (width direction) and 30cm (thickness direction). A non-sound area was defined as that 1) amplitude is below 20% and 2) carbonization and deterioration are related.

Evaluation of Post-LOCA Long Term Cooling Performance in Korean Standard Nuclear Power Plants

  • Bang, Young-Seok;Jung, Jae-Won;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.12-24
    • /
    • 2001
  • The post-LOCA long term cooling (LTC) performance of the Korean Standard Nuclear Power Plant (KSNPP) is analyzed for both small break loss-of-coolant accidents (LOCA) and large break LOCA at cold leg. The RELAP5/MOD3.2.2 beta code is used to calculate the LTC sequences based on the LTC plan of the Korean Standard Nuclear Power Plants (KSNPP). A standard input model is developed such that LOCA and the followed LTC sequence can be calculated in a single run for both small break LOCA and large break LOCA. A spectrum of small break LOCA ranging from \ulcorner.02 to 0.5 k2 of break area and a double-ended guillotine break are analyzed. Through the code calculations, the thermal-hydraulic behavior and the boron behavior are evaluated and the effect of the important action including the safety injection tank (SIT isolation and the simultaneous injection in LTC procedure is investigated. As a result, it is found that the sufficient margin is available in avoiding the boron precipitation in the core. It is also found that a further specific condition for the SIT isolation action need to be setup and it is recommended that the early initiation of the simultaneous injection be taken for larger break LTC sequences.

  • PDF

Development and Validation of Sky Simulator for Reproducing CIE Overcast Sky Model (돔형 인공천공의 개발 및 CIE표준담천공 구현 검증에 관한 연구)

  • Shin, Ju Young;Yun, Geun Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.97-103
    • /
    • 2010
  • Sky simulator is a effective daylighting design tool that can evaluate three dimensional performance of lighting. Especially, the dome type sky simulator offer reliable and reproducible daylighting performance with different standard sky models. Recently, K university has developed the dome type sky simulator(sky dome) with the diameter of 6.5m and the height of 3.7m. The sky dome consists of a group of 145 large steel panels with 72 halogen lamps which are arranged in a circular array. The luminance distribution of the sky dome can be calibrated by changing the angle and the brightness of the lamps respectively. To allow more reliable prediction and evaluation of daylighting through the sky dome, It is essential to validate the sky luminance distribution of the sky dome. This study consider the validation of the comparisons between the measured and the calculated luminance values for the CIE standard overcast sky. Also, the error rate between the measured and the calculated luminance values were compared to the previous studies. The results indicated that the K university sky dome can reproduce reliable CIE standard overcast sky with the average relative error rate of 4.4% and root-mean-square error(RMSE) of 5.4%.

Comparisons on Specifications of Mating Electrical Connectors for NASA Standard Initiators (나사 표준 착화기 (NASA Standard Initiators) 연결 전기 커넥터의 규격 비교)

  • Kim, In Sung;Jeong, Eun Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.418-422
    • /
    • 2017
  • Based on published materials, we compared specifications of mating electrical connectors for the NASA Standard Initiators NSI-1,2,3 with each other after the initiator specifications summary. The mating connector specifications for NSI-1,2 are MSFC-40M38298 and MIL-DTL-26482, series1 while for NSI-3 is MIL-DTL-38999, series3. The MIL-DTL-38999, series3 has the highest overall environmental resistance performance. MSFC-40M38298 is the next and MIL-DTL-26482, series1 follows. In particular, if initiators be used under severe shock and vibration environments, the MIL-DTL-38999, series3 should be applied.

  • PDF

Evaluation of Floor Impact Sound Isolation in a Dry Floor System (건식 바닥구조의 바닥충격음 차단성능 평가)

  • You, Jin;Ryu, Jong-Kwan;Jeon, Jin-Young;Lee, Chung-Hwa;Kim, Chul-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.950-953
    • /
    • 2005
  • Floor impact sounds from two different floor systems were measured. One of the two floor systems is a dry floor system (with 150mm concrete slab) and the other is a standard floor system (210mm concrete slab). Real impact sources such as jumping and running of children were used as well as standard impact sources (bang machine, impact ball and tapping machine) to evaluate sound Isolation of the two floor systems. Subjective evaluations of the floor impact sound isolation performance for the two systems were also conducted by the methods of 3 scales & 9 categories, paired comparison and semantic differentials. Measurement results indicate that floor impact sound isolation performance of the dry floor was better than that of standard floor in both cases of real and standard impact sources. The subjects in auditory experiments also evaluated the dry floor as a better sound isolation system.

  • PDF