• Title/Summary/Keyword: Performance Standard

Search Result 6,942, Processing Time 0.033 seconds

The Optimization and Verification of an Analytical Method for Sodium Iron Chlorophyllin in Foods Using HPLC and LC/MS (식품 중 철클로로필린나트륨의 HPLC 및 LC/MS 최적 분석법과 타당성 검증)

  • Chong, Hee Sun;Park, Yeong Ju;Kim, Eun Gyeom;Park, Yea Lim;Kim, Jin Mi;Yamaguchi, Tokutaro;Lee, Chan;Suh, Hee-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.148-157
    • /
    • 2019
  • An optimized analytical method for sodium iron chloriphyllin in foods was established and verified by using high performance liquid chromatography with attached diode array detection. An Inertsil ODS-2 column and methanol-water (80:20 containing 1% acetate) as a mobile phase were employed. The limit of detection and quantitation of sodium iron chloriphyllin were 0.1 and 0.3 mg/kg, respectively, and the linearity of calibration curve was excellent ($R^2=0.9999$). The accuracy and precision were 93.9~104.95% and 2.0~7.7% in both inter-day and intra-day tests. Recoveries for candy and salad dressing were ranged between 93 and 104% (relative standard deviation, (RSD) 0.3~4.3%), and between 83 and 115% (RSD 1.2~2.0%), respectively. Liquid chromatography mass spectrometry was used to verify the main components of sodium iron chlorophyllin which were Fe-isochlorin e4 and Fe-chlorin e4.

A Machine Learning-based Total Production Time Prediction Method for Customized-Manufacturing Companies (주문생산 기업을 위한 기계학습 기반 총생산시간 예측 기법)

  • Park, Do-Myung;Choi, HyungRim;Park, Byung-Kwon
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.1
    • /
    • pp.177-190
    • /
    • 2021
  • Due to the development of the fourth industrial revolution technology, efforts are being made to improve areas that humans cannot handle by utilizing artificial intelligence techniques such as machine learning. Although on-demand production companies also want to reduce corporate risks such as delays in delivery by predicting total production time for orders, they are having difficulty predicting this because the total production time is all different for each order. The Theory of Constraints (TOC) theory was developed to find the least efficient areas to increase order throughput and reduce order total cost, but failed to provide a forecast of total production time. Order production varies from order to order due to various customer needs, so the total production time of individual orders can be measured postmortem, but it is difficult to predict in advance. The total measured production time of existing orders is also different, which has limitations that cannot be used as standard time. As a result, experienced managers rely on persimmons rather than on the use of the system, while inexperienced managers use simple management indicators (e.g., 60 days total production time for raw materials, 90 days total production time for steel plates, etc.). Too fast work instructions based on imperfections or indicators cause congestion, which leads to productivity degradation, and too late leads to increased production costs or failure to meet delivery dates due to emergency processing. Failure to meet the deadline will result in compensation for delayed compensation or adversely affect business and collection sectors. In this study, to address these problems, an entity that operates an order production system seeks to find a machine learning model that estimates the total production time of new orders. It uses orders, production, and process performance for materials used for machine learning. We compared and analyzed OLS, GLM Gamma, Extra Trees, and Random Forest algorithms as the best algorithms for estimating total production time and present the results.

Development of Prediction Model for the Na Content of Leaves of Spring Potatoes Using Hyperspectral Imagery (초분광 영상을 이용한 봄감자의 잎 Na 함량 예측 모델 개발)

  • Park, Jun-Woo;Kang, Ye-Seong;Ryu, Chan-Seok;Jang, Si-Hyeong;Kang, Kyung-Suk;Kim, Tae-Yang;Park, Min-Jun;Baek, Hyeon-Chan;Song, Hye-Young;Jun, Sae-Rom;Lee, Su-Hwan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.316-328
    • /
    • 2021
  • In this study, the leaf Na content prediction model for spring potato was established using 400-1000 nm hyperspectral sensor to develop the multispectral sensor for the salinity monitoring in reclaimed land. The irrigation conditions were standard, drought, and salinity (2, 4, 8 dS/m), and the irrigation amount was calculated based on the amount of evaporation. The leaves' Na contents were measured 1st and 2nd weeks after starting irrigation in the vegetative, tuber formative, and tuber growing periods, respectively. The reflectance of the leaves was converted from 5 nm to 10 nm, 25 nm, and 50 nm of FWHM (full width at half maximum) based on the 10 nm wavelength intervals. Using the variance importance in projections of partial least square regression(PLSR-VIP), ten band ratios were selected as the variables to predict salinity damage levels with Na content of spring potato leaves. The MLR(Multiple linear regression) models were estimated by removing the band ratios one by one in the order of the lowest weight among the ten band ratios. The performance of models was compared by not only R2, MAPE but also the number of band ratios, optimal FWHM to develop the compact multispectral sensor. It was an advantage to use 25 nm of FWHM to predict the amount of Na in leaves for spring potatoes during the 1st and 2nd weeks vegetative and tuber formative periods and 2 weeks tuber growing periods. The selected bandpass filters were 15 bands and mainly in red and red-edge regions such as 430/440, 490/500, 500/510, 550/560, 570/580, 590/600, 640/650, 650/660, 670/680, 680/690, 690/700, 700/710, 710/720, 720/730, 730/740 nm.

Informed Consent and Refusal of Treatment in Emergency Medical Situation (응급의료에서의 설명·동의 원칙과 응급의료거부죄)

  • Lee, Jung-eun
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.1
    • /
    • pp.37-80
    • /
    • 2022
  • By analyzing informed consent and the refusal of emergency medical treatment (called patient dumping) under the current Emergency Medical Service Act, this study suggests that an emergency medical professional is only liable for patient dumping if their duty to protect the patient's life takes precedence over the patient's right to self-determination. In emergency medical situations, as in general medical situations, medical treatment should be performed after the emergency medical professional informs the patient about the medical treatment, including its necessity and methods, and obtains consent from the patient. Refusing or evading the performance of emergency medical services on the excuse of the informed consent not considering a waiver or alteration of informed consent requirements without reasonable reasons violates the Emergency Medical Service Act and thus makes an emergency medical professional liable to administrative disposition or criminal penalty. In other words, depending on the existence of a waiver of alteration of the informed consent, patient dumping may be established. If the patient is a minor or has no decision-making ability, and their legal representative makes a decision against the patient's medical interests, the opinion of the legal representative is not unconditionally respected. A minor also has the right to decide over their body, and the decisions of their legal representatives should be in the patient's best interests. If the patient refuses treatment, in principle, the obligation of life protection of emergency medical professionals is the top priority. However, making these decisions in the aforementioned situations in the emergency medical field is difficult because of the absence of explicit regulations regarding these exceptional problems. This study aims to organize the following precedents of the Supreme Court of Korea. The court states that, when balancing the conflicting interests between the duty to provide emergency medical service and the duty to inform is unavoidable for emergency medical professionals, they should put the duty to protect the patient's life ahead of the duty to inform if the patient's life matters. Exceptionally, when a patient has seriously considered whether they should receive treatment before the emergency medical situation, their right to self-determination can be considered equal to the obligation of emergency medical professionals to provide emergency medical treatment. This research also suggests that an amendment of the Emergency Medical Service Act should include the following. First, the criteria for determining the decision-making ability of emergency patients should consist of medical content. Second, additional consent from a medical professional is unnecessary for first-aid treatment. Finally, new provisions for emergency medical obligations for minors, new provisions for the decision standard when there are conflicting opinions about the treatment of a patient, and new penalty provisions for professionals who suspend emergency medical examinations and treatments need to be established.

Validation of an Analytical Method for Deacetylasperulosidic acid, Total Sugar and Monosaccharide Analysis in Fermented Morinda citrifolia Polysaccharide Powder (발효노니 다당체 분말의 deacetylasperulosidic acid, 총당 및 단당류 분석법 검증)

  • Kwon, Heeyeon;Choi, Jisoo;Kim, Soojin;Kim, Eunmin;Uhm, Jihyun;Kim, Bokyung;Lee, Jaeyeon;Kim, Yongdeok
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.4
    • /
    • pp.216-224
    • /
    • 2022
  • This study was aimed at validating the analysis methods for deacetylasperulosidic acid (DAA), total sugar, galacturonic acid, glucose, and galactose, which are the indicator components of fermented Morinda citrifolia polysaccharide extract (Vitalbos). We modified the previously reported methods for validating the analytical methods. The specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) were measured using phenol-sulfuric acid method and high-performance liquid chromatography (HPLC). The retention time and spectrum of the standard solution of Vitalbos coincided, confirming the specificity. The calibration curve correlation coefficient (R2), of five indicator components, ranged from 0.9995-0.9998, indicating excellent linearity of 0.99 or more. The intra-day and inter-day precision range of the assay was 0.14-3.01%, indicating a precision of less than 5%. The recovery rate was in the range of 95.13-105.59%, presenting excellent accuracy. The LOD ranged from 0.39 to 0.84 ㎍/mL and the LOQ ranged from 1.18 to 2.55 ㎍/mL. Therefore, the analytical method was validated for DAA, total sugar, galacturonic acid, glucose, and galactose, in Vitalbos. The indicator component content in Vitalbos was determined using a validated method. The contents of DAA, total sugar, galacturonic acid, glucose, and galactose were 2.31±0.06, 475.92±5.95, 72.83±1.05, 71.63±2.44, and 67.30±2.31 mg/g of dry weight, respectively. These results suggest that the developed analytical method is efficient and could contribute to the quality control of Vitalbos, as a healthy functional food material.

Study on Deriving Improvements through Analysis of BF Certification Evaluation Indicators for Parks and Park Facilities (공원 및 공원시설 BF인증 평가지표 분석을 통한 개선방향 도출 연구)

  • Kim, Mi Hye;Koo, Bonhak
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.13-29
    • /
    • 2022
  • According to the revision of the Convenience Act for Persons with Disabilities, parks and park facilities where the first park development plan is established after December 4, 2021 are mandatory, and parks must be equipped with convenience facilities for the disabled. Hence, this study aims to derive the improvements of the park evaluation index by analyzing the park certification evaluation index, the building certification evaluation index of park facilities, and the evaluation reports of the current certification status cases. As a research method, first, the certification of parks and park facilities were compared and reviewed with the Park Green Act, and differences in the certification process and certification performance were compared and analyzed. Second, differences and common items were derived by analyzing barrier free (BF)-certification evaluation indicators for parks and buildings. Third, improvement plans were derived after analyzing differences and problems in 4 BF-certified parks and four building certification cases of park facilities in certified parks, focusing on the self-evaluation report and examination results. As a result of analyzing the park and building evaluation indicators, the items for which the evaluation purpose, evaluation method, and evaluation items were commonly applied to 7 access roads for each facility, 5 parking areas for the disabled, 2 guide facilities for information facilities, 14 in 5 categories of sanitation facilities, and 1 for other facilities. In the case of sanitation facilities, there is no case where it was evaluated as a park. If the park does not have an attached toilet, the park is certified as a building. Hence, it would be essential to establish the concept of an attached toilet and discuss the application of the evaluation index on the park sanitation facility. The score of buildings in parks and park facilities was lower than that of the self-evaluation results, and the certification grades of buildings declined in three cases. The items with the highest standard deviation were BF walking continuity for parks and the path to the main entrance among access roads for buildings. As a result of analyzing the park and building evaluation results of 19 common evaluation items except for sanitary facilities, the difference in the grades of the evaluation items for each case site except for one item appeared. Therefore, applying common detailed calculation criteria for items evaluated in common with parks and buildings is needed. Since sanitation facilities have no cases of park certification and are not certified as buildings, it is essential to establish the concept of attached toilets and discuss the application of park sanitation evaluation indicators. It is necessary to develop an evaluation index suitable for the characteristics of the park, such as adjusting the items that are not evaluated in parks and establishing an evaluation index considering the ones of parks. It expects that this study would be used as primary data for improving park certification indicators.

A Method of Reproducing the CCT of Natural Light using the Minimum Spectral Power Distribution for each Light Source of LED Lighting (LED 조명의 광원별 최소 분광분포를 사용하여 자연광 색온도를 재현하는 방법)

  • Yang-Soo Kim;Seung-Taek Oh;Jae-Hyun Lim
    • Journal of Internet Computing and Services
    • /
    • v.24 no.2
    • /
    • pp.19-26
    • /
    • 2023
  • Humans have adapted and evolved to natural light. However, as humans stay in indoor longer in modern times, the problem of biorhythm disturbance has been induced. To solve this problem, research is being conducted on lighting that reproduces the correlated color temperature(CCT) of natural light that varies from sunrise to sunset. In order to reproduce the CCT of natural light, multiple LED light sources with different CCTs are used to produce lighting, and then a control index DB is constructed by measuring and collecting the light characteristics of the combination of input currents for each light source in hundreds to thousands of steps, and then using it to control the lighting through the light characteristic matching method. The problem with this control method is that the more detailed the steps of the combination of input currents, the more time and economic costs are incurred. In this paper, an LED lighting control method that applies interpolation and combination calculation based on the minimum spectral power distribution information for each light source is proposed to reproduce the CCT of natural light. First, five minimum SPD information for each channel was measured and collected for the LED lighting, which consisted of light source channels with different CCTs and implemented input current control function of a 256-steps for each channel. Interpolation calculation was performed to generate SPD of 256 steps for each channel for the minimum SPD information, and SPD for all control combinations of LED lighting was generated through combination calculation of SPD for each channel. Illuminance and CCT were calculated through the generated SPD, a control index DB was constructed, and the CCT of natural light was reproduced through a matching technique. In the performance evaluation, the CCT for natural light was provided within the range of an average error rate of 0.18% while meeting the recommended indoor illumination standard.

Evaluation of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR for the Diagnosis of Malaria (LG AdvansureTM Malaria P.f./P.v. real-time QPCR의 말라리아 진단 유용성)

  • Lee, Hye Jin;Kim, Ha Nui;Yoo, Byong Joon;Kim, Jang Su;Kim, Myong Han;Lim, Chae Seung;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.2
    • /
    • pp.100-104
    • /
    • 2011
  • Background: Malaria is a problematic disease in Korea, and microscopic examination of Giemsa-stained blood smear has been used as the gold standard for its diagnosis. However, this technique is time-consuming and has low sensitivity in samples with low numbers of malarial parasites (<20 parasites/μL). Here, we evaluated the performance characteristics of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR (LG life sciences, Korea). Methods: Blood samples from 173 persons who visited Korea University Ansan Hospital were evaluated. QPCR was performed in 73 malaria patients and 100 healthy subjects by using the LG Advansure Malaria P.f./P.v. real-time QPCRR kit, and the results were compared with those of microscopy. The detection limit of this kit was determined by serial dilution of Plasmodium-infected blood with normal blood (blood not infected with Plasmodium). Results: Among the 73 patients that were microscopically confirmed to have malaria (Plasmodium vivax infection, N=70, P. falciparum infection, N=3), 69 patients were diagnosed with P. vivax infection and 3 were diagnosed with P. falciparum infection by LG AdvansureTM Malaria P.f./P.v. realtime QPCR. Both the tests indicated absence of infection in the 100 healthy subjects. The detection limit of LG AdvansureTM Malaria P.f./P.v. real-time QPCR was 0.1 parasite/μL. Conclusions: LG AdvansureTM Malaria P.f./P.v. real-time QPCRis a very sensitive and specific technique and can be used as a confirmatory test for malaria.

Estimation for Ground Air Temperature Using GEO-KOMPSAT-2A and Deep Neural Network (심층신경망과 천리안위성 2A호를 활용한 지상기온 추정에 관한 연구)

  • Taeyoon Eom;Kwangnyun Kim;Yonghan Jo;Keunyong Song;Yunjeong Lee;Yun Gon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.2
    • /
    • pp.207-221
    • /
    • 2023
  • This study suggests deep neural network models for estimating air temperature with Level 1B (L1B) datasets of GEO-KOMPSAT-2A (GK-2A). The temperature at 1.5 m above the ground impact not only daily life but also weather warnings such as cold and heat waves. There are many studies to assume the air temperature from the land surface temperature (LST) retrieved from satellites because the air temperature has a strong relationship with the LST. However, an algorithm of the LST, Level 2 output of GK-2A, works only clear sky pixels. To overcome the cloud effects, we apply a deep neural network (DNN) model to assume the air temperature with L1B calibrated for radiometric and geometrics from raw satellite data and compare the model with a linear regression model between LST and air temperature. The root mean square errors (RMSE) of the air temperature for model outputs are used to evaluate the model. The number of 95 in-situ air temperature data was 2,496,634 and the ratio of datasets paired with LST and L1B show 42.1% and 98.4%. The training years are 2020 and 2021 and 2022 is used to validate. The DNN model is designed with an input layer taking 16 channels and four hidden fully connected layers to assume an air temperature. As a result of the model using 16 bands of L1B, the DNN with RMSE 2.22℃ showed great performance than the baseline model with RMSE 3.55℃ on clear sky conditions and the total RMSE including overcast samples was 3.33℃. It is suggested that the DNN is able to overcome cloud effects. However, it showed different characteristics in seasonal and hourly analysis and needed to append solar information as inputs to make a general DNN model because the summer and winter seasons showed a low coefficient of determinations with high standard deviations.

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.