• Title/Summary/Keyword: Performance Sensitivity

Search Result 2,717, Processing Time 0.029 seconds

Etherification of n-Butanol to Di-n-Butyl Ether over H3+xPW12-xNbxO40 (x=0, 1, 2, 3) Keggin and H6+xP2W18-xNbxO62 (x=0, 1, 2, 3) Wells-Dawson Heteropolyacid Catalysts (Keggin형 H3+xPW12-xNbxO40 (x=0, 1, 2, 3) 및 Wells-Dawson형 H6+xP2W18-xNbxO62 (x=0, 1, 2, 3) 헤테로폴리산 촉매를 이용한 n-Butanol로부터 Di-n-Butyl Ether의 제조)

  • Kim, Jeong Kwon;Choi, Jung Ho;Yi, Jongheop;Song, In Kyu
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.251-256
    • /
    • 2012
  • Etherification of n-butanol to di-n-Butyl Ether was carried out over Keggin $H_{3+x}PW_{12-x}Nb_xO_{40}$ (x=0, 1, 2, 3) and $H_{6+x}P_2W_{18-x}Nb_xO_{62}$ (x=0, 1, 2, 3) Wells-Dawson heteropolyacid catalysts. Niobium-substituted Keggin and Wells-Dawson heteropolyacid catalysts with different niobium content were prepared. Successful preparation of the catalysts was confirmed by FT-IR, ICP-AES, and $^{31}P$ NMR analyses. Their acid properties were determined by $NH_3$-TPD (Temperature-Programmed Desorption) measurements. Heteropolyacid catalysts showed different acid properties depending on niobium content in both series. The correlation between acid properties of heteropolyacid catalysts and catalytic activity was then established. Acidity of Keggin and Wells-Dawson heteropolyacid catalysts decreased with increasing niobium content, and conversion of n-butanol and yield for di-n-butyl ether increased with increasing acidity of the catalysts, regardless of the identity of heteropolyacid catalysts (without heteropolyacid structural sensitivity). Thus, acidity of heteropolyacid catalysts served as an important factor determining the catalytic performance in the etherification of n-butanol to di-n-Butyl Ether.

Dynamic Contrast-Enhanced MR Imaging in Detecting Local Tumor Progression after HIFU Ablation of Localized Prostate Cancer (국소적 전립선암의 고강도 집속 초음파 치료 후 국소적 암 재발의 발견과 역동적 조영증강 자기공명영상의 역할)

  • Park, Jung Jae;Kim, Chan Kyo;Lee, Hyun Moo;Park, Byung Kwan;Park, Sung Yoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.192-199
    • /
    • 2013
  • Purpose : To retrospectively evaluate the diagnostic performance of dynamic contrast-enhanced MR imaging (DCE-MRI) in detecting recurrent prostate cancer after HIFU of clinically localized cancer, as compared with T2-weighted imaging (T2WI). Materials and Methods: Twenty-six patients with increased prostate-specific antigen levels after HIFU were included in this study. All MR examinations were performed using T2WI and DCE-MRI, followed by transrectal ultrasound-guided biopsy. MRI and biopsy results were correlated in six prostate sectors. Residual or recurrent cancer after HIFU was defined as local tumor progression if biopsy results showed any cancer foci. Two independent readers interpreted the MR images. Results: Of 156 prostate sectors, 51 (33%) were positive for cancer in 17 patients. For detecting local tumor progression, the sensitivity of DCE-MRI and T2WI was 80% and 57% for reader 1 (P < 0.001) versus 84% and 61% for reader 2 (P < 0.001), respectively. The specificity and overall accuracy between DCE-MRI and T2WI showed no statistical difference in both readers (P > 0.05). Interobserver agreement of DCE-MRI and T2WI was moderate and fair, respectively. Conclusion: For detecting local tumor progression of prostate cancer after HIFU, DCE-MRI was more sensitive than T2WI, with less interobserver variability.

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.

Usefulness of Serum Thymidine Kinase 1 as a Biomarker for Aggressive Clinical Behavior in B-cell Lymphoma (B세포림프종의 임상적 악성도 표지자로서 혈청 Thymidine Kinase 1의 유용성)

  • Kim, Heyjin;Kang, Hye Jin;Lee, Jin Kyung;Hong, Young Jun;Hong, Seok-Il;Chang, Yoon Hwan
    • Laboratory Medicine Online
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • Background: The cell cycle-dependent enzyme thymidine kinase 1 (TK1) is known to increase during cancer cell proliferation and has been reported as a prognostic marker for various hematologic malignancies and solid tumors. This study aimed to determine the reference interval in Korean healthy controls and to evaluate the usefulness of TK1 as a biomarker for aggressive clinical behavior in B-cell lymphoma patients. Methods: We enrolled 72 previously untreated patients with B-cell lymphoma and 143 healthy controls. Serum TK1 levels were measured by chemiluminescence immunoassay ($Liaison^{(R)}$, DiaSorin, USA). We established the reference intervals in healthy controls. The diagnostic performance of serum TK1 was studied using receiver operating characteristic (ROC) analysis, and the correlation between the cutoff level for serum TK1 and clinical characteristics of B-cell lymphoma was evaluated. Results: The reference range (95th percentile) of serum TK1 in healthy controls was 5.4-21.8 U/L. There was a clear difference in TK1 levels between patients with B-cell lymphoma and healthy controls ($40.6{\pm}68.5$ vs. $11.8{\pm}4.4U/L$, P <0.001). The area under the curve of serum TK1 for the diagnosis of B-cell lymphoma was 0.73 (cutoff, 15.2 U/L; sensitivity, 59.7%; specificity, 83.2%). An increased TK1 level (${\geq}15.2U/L$) correlated with the advanced clinical stage (P <0.001), bone marrow involvement (P =0.013), international prognostic index score (P =0.001), lactate dehydrogenase level (P =0.001), low Hb level (<12 g/dL) (P =0.028), and lymphocyte count (P =0.023). Conclusions: The serum TK1 level could serve as a useful biomarker for aggressive clinical behavior in B-cell lymphoma patients.

A New Malting Barley Variety, "Daho" with High Yielding and BaYMV Resistance (맥주보리 호위축병저항성 및 다수성 "다호")

  • Hyun, Jong-Nae;Kim, Mi-Jung;Kim, Yang-Kil;Lee, Mi-Ja;Choi, Jae-Sung;Kim, Hyun-Tae;Han, Sang-Ik;Ko, Jong-Min;Lim, Sea-Gyu;Park, Jong-Chul;Kim, Jung-Gon;Suh, Sae-Jung;Kim, Dae-Ho;Kang, Sung-Ju;Kim, Sung-Taeg
    • Korean Journal of Breeding Science
    • /
    • v.41 no.3
    • /
    • pp.333-337
    • /
    • 2009
  • A new malting barley variety, "Daho", was developed from the cross between "Milyang85 and Suwon335" at the Department of Rice and Winter Cereal Crop (DRWCC) NICS, in 2007. An elite line, YMB2064-B-8-2-4-1-1, was selected in 2004 and designated as "Milyang134". It showed good agronomic performance in the regional adaptation yield trials (RYT) from 2005 to 2007 and was released with the name of "Daho", having high yielding and BaYMV resistance. The average heading and maturing dates of "Daho" were April 19 and May 27, which were 2 days later and 1 day earlier than those of "Jinyang", leading variety, at the regional adaptation yield trials (RYT), respectively. "Daho" had longer culm length (84 cm), more spikes per $m^2$ (915) and higher 1,000 grain weight (39.2 g) than those of "Jinyang" in paddy field condition. "Daho" was showed resistance to BaYMV at the regions of Naju, Jinju, and Milyang but moderately resistance at Iksan. However, the response of "Daho" to other environmental stresses was similar to "Jinyang". The yields of "Daho" at upland and paddy fields were about 5.20 MT/ha, 4.81 MT/ha, respectively, which is about 38%, 25% higher than those of "Jinyang" in the regional adaptation yield trials (RYT), respectively. It has higher grain assortment, germination capacity, water sensitivity and Kolback index but lower malt extract, diastatic power and filtration speed than those of "Jinyang".

A New High-Yielding Malting Barley Cultivar "Oreum" with High Yielding and BaYMV Resistance (호위축병저항성 다수성 맥주보리 "오름")

  • Hyun, Jong-Nae;Kim, Mi-Jung;Kim, Yang-Kil;Lee, Mi-Ja;Choi, Jae-Sung;Kim, Hyun-Tae;Han, Sang-Ik;Ko, Jong-Min;Lim, Sea-Gyu;Park, Jong-Chul;Kim, Jung-Gon;Suh, Sae-Jung;Kim, Dae-Ho;Kang, Sung-Ju;Kim, Sung-Taeg
    • Korean Journal of Breeding Science
    • /
    • v.41 no.3
    • /
    • pp.328-332
    • /
    • 2009
  • A new malting barley variety, "Oreum", was developed from the a cross between 'Kinuyutaka' and 'Samdobori' at the Honam Agricultural Research Institute (HARI) in 2006. An elite line, YMB2077-2B-24-1-2, was selected in 2003 and designated as 'Milyang132'. It showed good agronomic performance in the regional adaptation yield trials (RYT) from 2004 to 2006, and was released with the name of "Oreum" having high yielding and BaYMV resistance. The average heading and maturing dates of "Oreum" were April 18 and May 24, which were 2 days later than 'Jinyang', a leading variety, at RYT. "Oreum" had longer culm length (75 cm), more spikes per $m^2$ (990), and lighter 1,000 grain weight (35.2 g) than those of 'Jinyang' in paddy field conditions. It was showed resistance to BaYMV at the regions of Naju, Jinju and Milyang but moderate resistance at Iksan. However, the response to other environmental stresses of was similar to 'Jinyang' The yield potential of "Oreum" was about 5.43 MT/ha, 4.93 MT/ha in upland and paddy fields which was about 80%, 35% higher than Jinyang in the regional adaptation yield trials (RYT), respectively. It has good malting quality including high grain assortment, germination capacity ratio, water sensitivity and high the malt production and the extract and short filtration speed than those of 'Jinyang'.

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

Water Digital Twin for High-tech Electronics Industrial Wastewater Treatment System (II): e-ASM Calibration, Effluent Prediction, Process selection, and Design (첨단 전자산업 폐수처리시설의 Water Digital Twin(II): e-ASM 모델 보정, 수질 예측, 공정 선택과 설계)

  • Heo, SungKu;Jeong, Chanhyeok;Lee, Nahui;Shim, Yerim;Woo, TaeYong;Kim, JeongIn;Yoo, ChangKyoo
    • Clean Technology
    • /
    • v.28 no.1
    • /
    • pp.79-93
    • /
    • 2022
  • In this study, an electronics industrial wastewater activated sludge model (e-ASM) to be used as a Water Digital Twin was calibrated based on real high-tech electronics industrial wastewater treatment measurements from lab-scale and pilot-scale reactors, and examined for its treatment performance, effluent quality prediction, and optimal process selection. For specialized modeling of a high-tech electronics industrial wastewater treatment system, the kinetic parameters of the e-ASM were identified by a sensitivity analysis and calibrated by the multiple response surface method (MRS). The calibrated e-ASM showed a high compatibility of more than 90% with the experimental data from the lab-scale and pilot-scale processes. Four electronics industrial wastewater treatment processes-MLE, A2/O, 4-stage MLE-MBR, and Bardenpo-MBR-were implemented with the proposed Water Digital Twin to compare their removal efficiencies according to various electronics industrial wastewater characteristics. Bardenpo-MBR stably removed more than 90% of the chemical oxygen demand (COD) and showed the highest nitrogen removal efficiency. Furthermore, a high concentration of 1,800 mg L-1 T MAH influent could be 98% removed when the HRT of the Bardenpho-MBR process was more than 3 days. Hence, it is expected that the e-ASM in this study can be used as a Water Digital Twin platform with high compatibility in a variety of situations, including plant optimization, Water AI, and the selection of best available technology (BAT) for a sustainable high-tech electronics industry.

Influence of Land Cover Map and Its Vegetation Emission Factor on Ozone Concentration Simulation (토지피복 지도와 식생 배출계수가 오존농도 모의에 미치는 영향)

  • Kyeongsu Kim;Seung-Jae Lee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.1
    • /
    • pp.48-59
    • /
    • 2023
  • Ground-level ozone affects human health and plant growth. Ozone is produced by chemical reactions between oxides of nitrogen (NOx) and volatile organic compounds (VOCs) from anthropogenic and biogenic sources. In this study, two different land cover and emission factor datasets were input to the MEGAN v2.1 emission model to examine how these parameters contribute to the biogenic emissions and ozone production. Four input sensitivity scenarios (A, B, C and D) were generated from land cover and vegetation emission factors combination. The effects of BVOCs emissions by scenario were also investigated. From air quality modeling result using CAMx, maximum 1 hour ozone concentrations were estimated 62 ppb, 60 ppb, 68 ppb, 65 ppb, 55 ppb for scenarios A, B, C, D and E, respectively. For maximum 8 hour ozone concentration, 57 ppb, 56 ppb, 63 ppb, 60 ppb, and 53 ppb were estimated by scenario. The minimum difference by land cover was up to 25 ppb and by emission factor that was up to 35 ppb. From the modeling performance evaluation using ground ozone measurement over the six regions (East Seoul, West Seoul, Incheon, Namyangju, Wonju, and Daegu), the model performed well in terms of the correlation coefficient (0.6 to 0.82). For the 4 urban regions (East Seoul, West Seoul, Incheon, and Namyangju), ozone simulations were not quite sensitive to the change of BVOC emissions. For rural regions (Wonju and Daegu) , however, BVOC emission affected ozone concentration much more than previously mentioned regions, especially in case of scenario C. This implies the importance of biogenic emissions on ozone production over the sub-urban to rural regions.

Benchmark Test Study of Localized Digital Streamer System (국산화 디지털 스트리머 시스템의 벤치마크 테스트 연구)

  • Jungkyun Shin;Jiho Ha;Gabseok Seo;Young-Jun Kim;Nyeonkeon Kang;Jounggyu Choi;Dongwoo Cho;Hanhui Lee;Seong-Pil Kim
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.2
    • /
    • pp.52-61
    • /
    • 2023
  • The use of ultra-high-resolution (UHR) seismic surveys to preceisly characterize coastal and shallow structures have increased recently. UHR surveys derive a spatial resolution of 3.125 m using a high-frequency source (80 Hz to 1 kHz). A digital streamer system is an essential module for acquiring high-quality UHR seismic data. Localization studies have focused on reducing purchase costs and decreasing maintenance periods. Basic performance verification and application tests of the developed streamer have been successfully carried out; however, a comparative analysis with the existing benchmark model was not conducted. In this study, we characterized data obtained by using a developed streamer and a benchmark model simultaneously. Tamhae 2 and auxiliary equipment of the Korea Institute of Geoscience and Mineral Resources were used to acquire 2D seismic data, which were analyzed from different perspectives. The data obtained using the developed streamer differed in sensitivity from that obtained using benchmark model by frequency band.However, both type of data had a very high level of similarity in the range corresponding to the central frequency band of the seismic source. However, in the low frequency band below 60 Hz, data obtained using the developed streamer showed a lower signal-to-noise ratio than that obtained using the benchmark model.This lower ratio can hinder the quality in data acquisition using low-frequency sound sources such as cluster air guns. Three causes for this difference were, and streamers developed in future will attempt to reflect on these improvements.