• Title/Summary/Keyword: Performance Evaluations

Search Result 895, Processing Time 0.03 seconds

New Circuit Topology of Single-Ended Soft-Switching PWM High Frequency Inverter and Its Performance Evaluations

  • Deguchi Y.;Moisseev S.;Nakaoka M.;Hirota I.;Yamashita H.;Omori H.;Terai H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.247-250
    • /
    • 2001
  • This paper presents a simple and cost effective circuit topology of single-ended type high frequency quasi-resonant PWM inverter using IGBTs, which can operate under wide soft switching operation range based on ZCS for main power switch as compared with a conventional active voltage-clamped ZVS-PWM high frequency quasi-resonant inverter developed previously. In principle, this new circuit topology can efficiently operate under a constant frequency PWM control-based power regulation scheme. In particular, it is noted that the zero current soft switching (ZCS) commutation can achieve for the main active power switch. On the other hand, the zero voltage soft switching (ZVS) commutation can also achieve for the auxiliary active power switch. The operating principle of this high-frequency Inverter treated here and its power regulation characteristics are illustrated on the basis of the simulation and feasible experimental results.

  • PDF

ZVS-PWM Boost Chopper-Fed DC-DC Converter with Load-Side Auxiliary Edge Resonant Snubber

  • Ogura K.;Chandhaket S;Nagai S;Ahmed T;Nakaoka M
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.223-226
    • /
    • 2003
  • This paper presents a high-frequency ZVS-PWM boost chopper-fed DC-DC converter with a single active auxiliary edge-resonant snubber which is used for power conditioner such as solar photovoltaic generation and fuel cell generation. The experimental results of boost chopper fed ZVS-PWM DC-DC converter are evaluated. In audition to its switching voltage and current waveforms, and the switching v-i trajectory of the power devices are discussed and compared with the conventional hard switching DC-DC converter treated here. The temperature performance of IGBT module,, efficiency, and EMI noise characteristics of this ZVS-PWM DC-DC converter using IGBTs are measured and evaluated from an experimental point of view.

  • PDF

Evaluations of Three Phase Shift Models in Describing Phase Shift Impulse Train Response of a Simple Planar Oscillator (간단한 2차원 오실레이터의 임펄스열 응답에 관한 3가지 위상편이 모델의 평가)

  • Jeon, Man-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.8
    • /
    • pp.861-866
    • /
    • 2014
  • This study evaluates the modeling accuracy of the existing three phase shift models on which the time domain oscillator phase noise theories are based. For the evaluation, this study investigates how accurately the three models can model the phase shift impulse train response of a simple planar oscillator. Evaluation result reveals that Kaertner model most accurately reflects the oscillator's phase shift impulse train responses for five different impulse train inputs, whereas PP model exhibited the worst performance in modeling the phase shift impulse train responses.

A Study about Experimental Evaluation of an Ultrasonic Surgery Unit for Bone-cutting (골 절삭용 초음파 수술기의 실험적 평가에 관한 연구)

  • Sa, Min-Woo;Shim, Hae-Ri;Ko, Tae-Jo;Lee, Jong-Min;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In the dentistry field, an ultrasonic surgery unit is widely used in bone cutting and scaling to reduce operation time and minimize hemorrhage. The purpose of this study was to evaluate bone cutting and the effect of a specimen's temperature on the two-type ultrasonic surgery unit using a handpiece moving system(HMS). A HMS, which can cut the bone, was developed to perform the experimental procedure with precision of motion control. Bone specimens were prepared from a combination of epoxy-hardener and cortical bone of bovine leg. Through the bone-cutting experiment, the cutting depth was evaluated by not only scanning electron microscopy, but also Vernier calipers. Also, the temperature distribution was measured by a thermo-graphic camera. This study may be applied methodically in various experimental evaluations on a performance test by a HMS.

Empirical Evaluation of Optimal User-Centered LED Lighting Environments in Residential Bathrooms

  • Lee, Jeongmin;Choi, Kyungah;Suk, Hyeon-Jeong
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.305-310
    • /
    • 2013
  • This user-centered research aims to empirically evaluate color temperature (K) and illuminance (lx) of residential bathroom lightings to determine the most optimal lighting conditions for productive task performance as well as for satisfying users' emotional needs. Using 3 LED lighting fixtures, 4 types of lighting contexts were investigated; main lighting, task lighting, shower lighting, and bath lighting. Two lightings were installed parallel to the vertical edges of the main bathroom mirror to be used as main and task lighting, while another fixture was installed above the bathtub to be used for shower and bathing. For each lighting context, subjects (N=54) were instructed to perform a few tasks during which time the users were exposed to different lighting conditions with color temperature ranging from 2700 K ~ 6500 K and illuminance ranging from 100 lx ~ 700 lx. Upon completing the given tasks, subjects were asked to evaluate the lighting conditions and their applicability for performing the given tasks. Based on the user evaluations, the most optimal lighting conditions for the different lighting scenarios are as follow: 1) 3500 K ~ 4300 K and 150 lx for main lighting, 2) 3500 K ~ 4300 K and 500 lx ~ 700 lx for task lighting, and 3) 2700 K ~ 3500 K and 100 lx ~ 150 lx for shower/bath lighting. These results can be used to adjust the lighting standards suggested by KS, as well as be utilized by both engineers and designers in designing new types of user-centered bathroom lightings.

  • PDF

Microstructures and Mechanical Properties of Age Hardenable Cu-2.0wt%Be Alloy for Projection Welding Electrode (프로젝션 용접 전극을 위한 시효경화성 Cu-2.0wt%Be 합금의 미세조직과 기계적성질)

  • Kim, Gwangsoo;Kim, Jinyong
    • Korean Journal of Materials Research
    • /
    • v.25 no.9
    • /
    • pp.468-474
    • /
    • 2015
  • Evaluations of the microstructure and mechanical properties of age hardenable Cu-2.0wt%Be alloy are performed in order to determine whether it can be used as a welding electrode for projection welding. The microstructure examinations, hardness measurements, and tensile tests of selective aging conditions are conducted. The results indicate that the aging treatment with the fine-grained microstructure exhibits better hardness and high tensile properties than those of the coarse-grained microstructure. The highest hardness value and high tensile strength are obtained from the aged condition of $300^{\circ}C$ for 360 min due to the presence of the metastable ${\dot{\gamma}}$ precipitates on the grain boundaries. The values of the highest hardness and tensile strength are measured as 374 Hv and 1236.2 MPa, respectively. The metastable ${\dot{\gamma}}$ precipitates are transferred to the equilibrium ${\gamma}$ precipitates due to the over-aged treatment. The presence of the ${\gamma}$ precipitates appears as nodule-like precipitates decorated around the grain boundaries. The welding electrode with the best aging treated condition exhibits better welding performance for electrodes than those of electrodes used previously.

Scoping Analyses for the Safety Injection System Configuration for Korean Next Generation Reactor

  • Bae, Kyoo-Hwan;Song, Jin-Ho;Park, Jong-Kyoon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.395-400
    • /
    • 1996
  • Scoping analyses for the Safety Injection System (SIS) configuration for Korean Next Generation Reactor (KNGR) are peformed in this study. The KNGR SIS consists of four mechanically separated hydraulic trains. Each hydraulic train consisting of a High Pressure Safety Injection (HPSI) pump and a Safety Injection Tank (SIT) is connected to the Direct Vessel Injection (DVI) nozzle located above the elevation of cold leg and thus injects water into the upper portion of reactor vessel annulus. Also, the KNGR is going to adopt the advanced design feature of passive fluidic device which will be installed in the discharge line of SIT to allow more effective use of borated water during the transient of large break LOCA. To determine the feasible configuration and capacity of SIT and HPSI pump with the elimination of the Low Pressure Safety Injection (LPSI) pump for KNGR, licensing design basis evaluations are performed for the limiting large break LOCA. The study shows that the DVI injection with the fluidic device SIT enhances the SIS performance by allowing more effective use of borated water for an extended period of time during the large break LOCA.

  • PDF

An Exploratory Study on the Disposable Sanitary Pads for User-Oriented Product Design (사용자 중심 제품설계를 위한 일회용 생리대의 탐색적 연구)

  • Jeon, Eun-Kyung;Moon, Ji-Hyun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.1
    • /
    • pp.167-174
    • /
    • 2010
  • This paper aims to examine the status of sizing specifications for disposable sanitary pads on the market and to offer information on product design that reflect the requests of consumer by gathering opinion through the practical experience of consumers. Seventy-six varieties of sanitary pads on market are measured and the evaluations of wearing comfort were investigated by the questionnaire and interview for sixty three varieties of sanitary pads. As a result, they were classified into five sizes related with length but vaguely related with thickness and width. Thickness is distinguished by the compressibility that is marked as slim or ultra slim by the same brand. However, there is no sizing consistency for all products. The result shows that there is some confusion for consumers to choose desired sizes, In addition, the perception of wearing is categorized into four factors that are product performance, size and fit, wearing feeling and margin of action, and adhesive property and wrapping. The manufacturing specifications for the sanitary pads on domestic market, the requests of consumers for sanitary pad design modifications, and proposals for follow-up studies were figured out through this research.

A Design and Application of the Ventilating and Heating System of T-103 Trainer Aircraft for Improvement (T-103 훈련기의 환기와 난방 시스템 개선에 관한 연구)

  • Jung, Daehan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.277-284
    • /
    • 2013
  • In this paper, the ventilating and heating system of T-103 trainer aircraft were investigated and redesigned to improve its poor performance. The ventilation system of the trainer was designed to increase the mass flow rate of fresh air by using air intake valves. The flow-in air through the air intake valve is supplied to the cabin by the ram effect of aircraft and the propeller. And the additional heating system was installed to improve the temperature of the cabin inside. The wasted heat from the exhaust gas of the engines was used as heat source of the additional heating system by installing an heat exchanger around the exhaust nozzle. The additional fresh air and the heated air enter the cabin via two ducts mounted under the instrument panel and behind the pedal in the cabin. The additional ventilating and heating system can be controlled by the first pilot and the secondary pilot individually using the control knob equipped separately. After mounting the additional ventilating and heating system, evaluations such as inspection of parts and component, ground run-up test, in-flight test, user test, etc. were conducted. The result of the tests was sufficient to meet the requirements of the manuals, and the pilots were satisfied with the additionally mounted systems.

Analysis of Characteristics of Air Pollution Over Asia with Satellite-derived $NO_2$ and HCHO using Statistical Methods (환경 위성관측자료의 통계분석을 통한 동아시아 대기오염특성 연구)

  • Baek, K.H.;Kim, Jae Hwan
    • Atmosphere
    • /
    • v.20 no.4
    • /
    • pp.495-503
    • /
    • 2010
  • Satellite data have an intrinsic problem due to a number of various physical parameters, which can have a similar effect on measured radiance. Most evaluations of satellite performance have relied on comparisons with limited spatial and temporal resolution of ground-based measurements such as soundings and in-situ measurements. In order to overcome this problem, a new way of satellite data evaluation is suggested with statistical tools such as empirical orthogonal function(EOF), and singular value decomposition(SVD). The EOF analyses with OMI and OMI HCHO over northeast Asia show that the spatial pattern show high correlation with population density. This suggests that human activity is a major source of as well as HCHO over this region. However, this analysis is contradictory to the previous finding with GOME HCHO that biogenic activity is the main driving mechanism(Fu et al., 2007). To verify the source of HCHO over this region, we performed the EOF analyses with vegetation and HCHO distribution. The results showed no coherence in the spatial and temporal pattern between two factors. Rather, the additional SVD analysis between $NO_2$ and HCHO shows consistency in spatial and temporal coherence. This outcome suggests that the anthropogenic emission is the main source of HCHO over the region. We speculate that the previous study appears to be due to low temporal and spatial resolution of GOME measurements or uncertainty in model input data.