• Title/Summary/Keyword: Performance Evaluation of Facility

Search Result 339, Processing Time 0.026 seconds

Development of an Economic Evaluation model for Coating System Based on Environmental Conditions of Power Generation Structure (발전구조물의 환경조건을 반영한 도장계 선정 경제성 평가 모델 개발)

  • Kim, In Tae;Lee, Su Young;An, Jin Hee;Kim, Chang Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.77-85
    • /
    • 2020
  • Currently, life-cycle cost analysis methods are introduced to maintain large infrastructure facilities in Korea. However, there are not many cases in which maintenance models are applied that reflect conditions such as the location of a facility and its surroundings. In order to establish an appropriate maintenance strategy, a cost prediction, deterioration model, and a decision model reflecting uncertainty should be established. In this study, an economic analysis model was developed for long-term cost planning and management based on user decisions based on maintenance methods and judgment criteria for painting specifications applied to power generation structures. The performance of the paintwork was assessed through the paint deterioration test for the application of the economic analysis model, and the results of the economic analysis according to the applied paint specifications (Urethan, polysiloxane, fluorine) were verified by applying the proposed economic analysis model. In this study, it is believed that the selection of the repair cycle and evaluation methods applied with the development model rather than the performance of the painting can be expected to be used as basic data for the maintenance cycle, even if it is not limited to the painting.

Performance Evaluation Criteria for the Sustainable Operation of Community Facilities in Urban Regeneration (도시재생 공동이용시설의 지속적인 운영을 위한 평가지표 제안)

  • Jung-Eun Lee;Soung-Eun Park;Yunmi Park
    • Land and Housing Review
    • /
    • v.15 no.3
    • /
    • pp.79-95
    • /
    • 2024
  • Over the past decade, urban regeneration projects have been actively promoted nationwide in South Korea, leading to the establishment of numerous community facilities aimed at fostering community engagement and revitalization. Recently, the need for diagnostic tools to provide appropriate support and guidance for the sustainable operation of these facilities has been increasingly emphasized. However, a comprehensive manual or nationwide standard approach remains lacking. As such, this study aims to propose evaluation criteria and their application methods for the periodic operational assessment of those facilities. First, through a review of previous studies, candidate indicators were identified. After that, preliminary indicators and frameworks were determined through expert consultations, followed by surveys conducted with 65 experts to finalize the evaluation indicators. The survey results highlighted the importance of 'Value Creation (VC)' and 'Operation Management (OM)' as key aspects of facility evaluation. In assessing VC, key factors include enhancing community vitality, strengthening local capacity, providing tailored functions for the community, and contributing to the local economy. In constructing OM, the focus lies on operational system, financial management, operational personnel, and economic viability and sustainability. This study proposes an evaluation framework that includes the final evaluation indicators and available data sources for each indicator, and a pilot test was conducted to verify its applicability. Moreover, the study suggests directions for utilizing the evaluation criteria and methods for applying indicators tailored to the characteristics of individual facilities.

Technical Standards and Safety Review of the Low and Intermediate Level Radioactive Waste Disposal Facility (중.저준위 방사성폐기물 처분시설에 대한 기술기준 및 안전심사)

  • Cheong, Jae-Hak;Lee, Kwan-Hee;Lee, Yun-Keun;Jeong, Chan-Woo;Rho, Byung-Hwan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.357-368
    • /
    • 2008
  • On July 31, 2008, the Government issued the construction and operation permit for the first low and intermediate level radioactive waste disposal facility in the Republic of Korea. In this paper, the fundamental regulatory framework, regulatory requirements and technical standards of the disposal facility are introduced, and the phased review process adopted for evaluation of the safety of the facility is briefly described. The Atomic Energy Act sets forth a stepwise regulatory framework for the whole life-cycle of the disposal facility such as siting, design, construction, operation, closure and institutional control. More detailed regulatory requirements and technical standards are stipulated in the subsequent regulations of the Atomic Energy Act and a series of Notices issued by the Ministry of Eduction, Science and Technology. The Korea Institute of Nuclear Safety, as entrusted by the Ministry under the Atomic Energy Act, conducted safety review on the disposal facility, and evaluated the compliance with relevant criteria in all technical elements(i.e. siting and structural safety, radiological environmental impact, operational safety, systems and components, quality assurance, and total systematic performance assessment, etc.). The overall safety review process can be phased into inception phase, initial review phase, main review phase and completion phase. The review results were reported to and deliberated by the five Sub-committees of the Special Committee on Nuclear Safety, and then reported to the Ministry. The Ministry issued the construction and operation permit of the disposal facility through the deliberation of the review results by the Nuclear Safety Commission. Hereafter, the safety of the repository will be reassured by a series of subsequent regulatory inspections and reviews under the Atomic Energy Act. In addition, the licensee's continuous implementation of the "Safety Promotion Plan" may also enhance the long-term safety of the repository and contribute to build-up the confidence of the safety case.

  • PDF

A Study on the Activity of Occupational Health Nurses in Occupational Group Health Service (보건관리대행기관 산업보건간호사의 업무에 관한 조사)

  • Kim, Ja Hee
    • Korean Journal of Occupational Health Nursing
    • /
    • v.3
    • /
    • pp.5-20
    • /
    • 1993
  • This study was aimed to investigate the actual condition of the performance of the occupational health nursing services, and to analyze a main cause which affects on the execution of its duties for occupational health nurses in occupational group health service. It had been surveyed by responsed data from the 105 respondents out of 180 persons. The results were as follows : 1. In performance of occupational health nursing services by the number of assigned plant, participation rate of health examination tended to significantly increase with decreasing the number of assigned and it was observed that the visiting rate of every month was also significantly higher on touring inspection of work plant, recommendation of facility improvement for work environment, understanding the modification of manufacturing process, and inspection of welfare and sanitation facilities. 2. While they executed their nursing services according to duration of service, the more, their duration of service was, the higher, participation rate of health examination, health check in returning to work for injured workers, talk with other health managers on promoting welfare, service evaluation for a year plan, record of health statistic, and experience of first aid service were. And it was found out that the visiting rate of every month was also significantly higher on touring inspection of work plant. 3. In regard to occupational health nursing services by age, the participation rate of health examination and the experience of first aid service were significantly higher as the age increased. And also the visiting rate of every month was significantly higher on touring inspection of work plant, compared with young ones. 4. In performance of occupational health nursing services by the time required visiting plant, The shorter, the time required visiting plant was, the higher, the visiting rate of every month was, on time of health consultation for diseased workers, and inspection of welfare and sanitation facilities. 5. The subjects of health education were mostly liver disease and occupational hearing loss and video tape was used mostly in health education, monthly health education was the highest in 1-3 times(74.5%) and its duration was the highest in about 60 minutes(33.3%). 6. Vaccination of hepatitis among the specific health services was the highest accounting for 64.7%.

  • PDF

Assessment of Foodservice Management Performance at Child Care Centers (보육시설 급식운영관리 실태 조사)

  • Lee Mee-Sook;Lee Jae-Yeon;Yoon Sun-Hwa
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.2
    • /
    • pp.229-239
    • /
    • 2006
  • This study was carried out to investigate foodservice management practices of 100 child care centers nationwide, and to provide background information for developing foodservice management policies at child care centers. Approximately 20% of the child care centers had a separate dining room; most of the centers were vulnerable to sanitation or safety problems. The percentage of the centers that planned menus was about 60% and 10% established standardized recipes. Fourteen percent of the centers kept records for distribution and menu evaluation and 33% kept sanitation management records. Since only 7% of the centers employed a dietitian, foodservice in most centers were not managed by professionals. The results of menu assessment revealed that 56.5% of the national/public child care centers received 19 points or higher out of 21 points, whereas 5.6% of the private child care centers received the same scores. Proper usage and storage of raw food, sanitary management of equipment and facilities, waste management/leftover food treatment, and basic facility of cooking zones were performed well by many centers. The overall scores of foodservice performance were only 31.2 out of 60 points, representing relatively poor safety management, food procurement management, and facilities and equipment management. These results indicate that the foodservice management of the child care centers are in a relatively poor state. Since nutrition management of the most centers was performed by non-professionals, it may not be possible to provide proper nutrition for health and normal growth of preschool children and to perform efficient nutrition education programs. The following suggestions are strongly recommended in order to improve foodservice performance at child care centers. First, foodservice administration should be performed by a dietitian, and second, efforts should be focused on strengthening nutrition and sanitation management.

An Evaluation and Prediction of Performance of Road Snow-melting System Utilized by Ground Source Heat Pump (지열원히트펌프를 활용한 도로융설시스템의 성능 평가 및 예측)

  • Choi, Deok-In;Hwang, Kwang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.138-145
    • /
    • 2012
  • Because of the climate changes and the development of building technologies, the cooling loads have been increased. Among the various renewable energies, geothermal energy is known as very useful and stable energy for heating and cooling of building. This study proposes a road snow-melting system of which heat is supplied from GSHP(Ground source heat pump) in viewpoint of the initial investment and annual running performance, which is also operating as a main facility of heating and cooling for common spaces. The results of this study is as followings. From the site measurement, it is found out that the road surface temperature above the geothermal heating pipe rose up to $5^{\circ}C$, which is the design temperature of road snow-melting, after 2 hours' operation and average COP(Coefficient of performance) was estimated as 3.5. The reliability of CFD has confirmed, because the temperature difference between results of CFD analysis and site measurement is only ${\pm}0.4^{\circ}C$ and the trend of temperature variation is quite similar. CFD analysis on the effect of pavement materials clearly show that more than 2 hours is needed for snow-melting, if the road is paved by ascon or concrete. But the road paved by brick is not reached to $5^{\circ}C$ at all. To evaluate the feasibility of snow-melting system operated by a geothermal circulation which has not GSHP, the surface temperature of concrete-paved road rise up to $0^{\circ}C$ after 2 hour and 40 minutes, and it does never increase to $5^{\circ}C$. And the roads paved by ascon and brick is maintained as below $0^{\circ}C$ after 12 hours geothermal circulation.

Performance Evaluation of Sintered Metal Filter in LILW Vitrification Facility (중.저준위 방사성폐기물 유리화설비에서 금속필터 적용성평가)

  • Park, Seung-Chul;Kim, Byong-Ryol;Hwang, Tae-Won
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.146-153
    • /
    • 2006
  • A performance test of the stainless steel based sintered metal filter was conducted on the low and intermediate level radioactive waste (LILW) vitrification process. The applicability of the metal filter was based on the test results as well. The baseline pressure drop of the metal filter was evaluated similar to the ceramic filter. During the test, when the flow rate of off-gas was $110Nm^{3}/h$, the total baseline pressure drop was shown as $92mmH_{2}O$. The total pressure drop was attributed to the filter media and the residual dust layer and the value of each was $25mmH_{2}O\;and\;67mmH_{2}O$ respectively. The SEM-EDS spectrum and micrograph of the metal filter specimen showed, no corrosion and no physical damage both at the skin membrane and at the support layer. And most of the baseline pressure drop was caused by the deposition of dust on the surface of the membrane. In conclusion, even though the filter exposure time was short at the test, the performance of the stainless steel based metal filter was acceptable for the treatment of LILW vitrification process.

Flight Test Measurement and Assessment of a Flapping Micro Air Vehicle

  • Kim, Jong-Heon;Park, Chan-Yik;Jun, Seung-Moon;Chung, Dae-Keun;Kim, Jong-Rok;Hwang, Hee-Chul;Stanford, Bret;Beran, Philip;Parker, Gregory;Mrozinski, Denny
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.238-249
    • /
    • 2012
  • Flight test of flapping micro air vehicles (FMAVs) is carried out using an instrumented measurement system to obtain various engineering parameters and hence to assess the flight performance of the vehicles through the data investigation. An indoor flight test facility equipped with a motion capture system and tracking cameras is used for the work presented in this paper. Maneuvers including straight-level flight, ground flapping, takeoff and landing are tested. Spatial position and orientation data are obtained from the retro-reflective tracking markers attached to the vehicles. Subsequent test analysis is carried out by generating performance parameters from raw data and then assessing the flight performance by comparison of the vehicles. The main findings of this work confirm that the test method and procedures presented here enable the systematic numerical data measurement and assessment of the flying performances of these vehicles, and show the applicability for the test and evaluation of general flapping MAVs.

An Enhanced Counterpropagation Algorithm for Effective Pattern Recognition (효과적인 패턴 인식을 위한 개선된 Counterpropagation 알고리즘)

  • Kim, Kwang-Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.9
    • /
    • pp.1682-1688
    • /
    • 2008
  • The Counterpropagation algorithm(CP) is a combination of Kohonen competition network as a hidden layer and the outstar structure of Grossberg as an output layer. CP has been used in many real applications for pattern matching, classification, data compression and statistical analysis since its learning speed is faster than other network models. However, due to the Kohonen layer's winner-takes-all strategy, it often causes instable learning and/or incorrect pattern classification when patterns are relatively diverse. Also, it is often criticized by the sensitivity of performance on the learning rate. In this paper, we propose an enhanced CP that has multiple Kohonen layers and dynamic controlling facility of learning rate using the frequency of winner neurons and the difference between input vector and the representative of winner neurons for stable learning and momentum learning for controlling weights of output links. A real world application experiment - pattern recognition from passport information - is designed for the performance evaluation of this enhanced CP and it shows that our proposed algorithm improves the conventional CP in learning and recognition performance.

Development of Hybrid Energy Harvesting Block and Evaluation on Power Generation Performance (하이브리드 에너지하베스팅 블록 개발 및 발전성능 평가)

  • Kim, Hyo-Jin;Park, Ji-Young;Jin, Kyu-Nam;Noh, Myung-Hyun
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.99-106
    • /
    • 2014
  • The purpose of this study is to develop hybrid energy blocks with piezoelectric and electromagnetic induction method. The developed energy block is able to be applied to the housing and facilities in the city and is suitable to adjust the characteristics of facilities. To develop the hybrid energy block, we analyzed the characteristics and requirements of various energy block types and drew improvement and application method to develop energy blocks. We compared and analyzed the characteristics and performance of the prototype energy blocks and the developed hybrid energy blocks. According to result of the comparison and analysis, the developed energy block shows higher performance of 12.7 times for adding one vibration and 28.9 times for five consecutive vibrations than that of a existing prototype energy block. This is consistent with research purposes for W-level electrical energy production. Thus, the new energy block will likely be possible to apply to the housing and urban facility.