• Title/Summary/Keyword: Performance Evaluation of Facility

Search Result 329, Processing Time 0.032 seconds

Performance Evaluation on Educational Program for Employees of the Work-Learning Dual System Training Center (일학습병행 공동훈련센터 전담자 교육훈련 효과성 분석 연구)

  • Tae-Seong Kim
    • Journal of Practical Engineering Education
    • /
    • v.16 no.2
    • /
    • pp.215-226
    • /
    • 2024
  • This study analyzed the performance of educational program for the employees of the work-learning dual system training center using the results of the satisfaction survey of 2,543 and then, suggested implications for enhancing the effectiveness of the curriculum. As a result of the analysis, this educational program showed very high level of satisfaction and was evaluated to provide successful education. Education participant satisfaction was found to be affected by the curriculum situation and participant characteristics. Satisfaction in terms of instructor, subject, facility environment, and operation was all found to have a significant influence on the effectiveness of the educational program for employees of the work-learning dual system training center.

A Study about False Alarm of Automatic Fire Detection System (자동화재 탐지설비의 비화재보 감소방안)

  • Lee, Jong-Hwa;Lee, Chun-Ha;Kim, Shi-Kuk;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • The automatic fire detection system is an important facility installed with focusing on minimizing the damage from a fire. This paper presents in the followings as the methods to reduce the false alarm of the automatic fire detection system; first, to prepare for legal standard so that revised legal standard can be applied to the fire fighting property prior to revision; second, to introduce the performance based fire detection protection design in the law based fire protection design; third, to maintain the wiring of worn-out detector; forth, to introduce an evaluation system to the education for the fire warden; fifth, to extend the standard of MTBF(meantime between failure) of the detector; sixth, to extend of installing the analog type detector; seventh, to improve the structure of reset switch.

A Study on Trends of Library Management Research in Korea: Focused on Academic Papers 2004~2013 (한국 도서관경영 연구의 동향 - 2004~2013 학술논문을 중심으로 -)

  • Lee, Yong Jae;Kim, Kyoung Doc
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.48 no.4
    • /
    • pp.25-50
    • /
    • 2014
  • The purpose of this study is to analyze academic research trends of the library management in Korea. Especially, this study focused on research trend analysis according to the sub categories of library management. For this purpose, this study analyzed a total of 359 papers of library and information science from 2004 to 2013 at the four academic journals of the National Research Foundation of Korea. As a result, it was found that the sub field which showed the highest performance was 'general management' and following sub fields were 'measurement and evaluation', 'human resource management', 'building and facility', 'policy and system.' However, there has been relatively less performance in the sub fields like 'marketing', 'organization management', 'budget management'.

Remodeling Process Model Applying Service Life and Functionality Evaluation for Military Facilities (내용연수와 기능성 평가를 활용한 군 시설물 리모델링 대상 선정 프로세스 모델)

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Kim, Jaegon;Moon, Hyo-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.6
    • /
    • pp.41-52
    • /
    • 2015
  • The number of military facilities has been rapidly increased due to growing requirement of modernization and military welfare. However, adequate maintenance has not implemented to these facilities. As a result, they are deteriorated quickly and require performance enhancement treatments. There are two ways of performance enhancement, reconstruction and remodeling. Despite the research result that remodeling within the standard remodeling range is more economical, remodeling of military facilities is not considered equivalent to reconstruction as an option of performance improvement. Therefore, derived from the relationship between performance change during life cycle of building and range of remodeling needs, this study tries to propose Remodeling Process Model(RPM) which uses a method to choose remodeling in a Specific Point of Time(SPT) when remodeling is considered more economical than reconstruction. In addition, this study suggests practical service life and functionality evaluation standard together which require to realize the RPM. This RPM make it possible to avoid the cases that facilities which do not have any problem on structural reliability but have low level of functionality miss appropriate remodeling timing and inevitably choose reconstruction as a performance improvement option. It also present the possibility of simple reconstruction / remodeling decision-making for facility managers who administrate building having various type, compilation and elapsed time. Consequently, this process model focusing on remodeling more may contribute to reduce resource waste caused by reconstruction.

Evaluation on the implications of microbial survival to the performance of an urban stormwater tree-box filter

  • Geronimo, Franz Kevin;Reyes, Nash Jett;Choi, Hyeseon;Guerra, Heidi;Jeon, Minsu;Kim, Lee-Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.128-128
    • /
    • 2021
  • Most of the studies about stormwater low impact development technologies used generalized observations without fully understanding the mechanisms affecting the whole performance of the systems from catchment to the facility itself. At present, these LID technologies have been treated as black box due to fluctuating flow and environmental conditions affecting its operation and treatment performance. As such, the implications of microbial community to the overall performance of the tree-box filter were investigated in this study. Summer season was found to be the most suitable season for microorganism growth since more microorganism were found during this season. Least microorganism count was found in spring because of the plant growth during this season since plant penology influences the seasonal dynamics of soil microorganisms. Litterfall during fall season might have affected the microorganism count during winter since, during this season, the compositional variety of soil organic matter changes affecting growth of soil microbial communities. Microbial analyses of sediment samples collected in the system revealed that the most dominant microorganism phylum is Proteobacteria in all the seasons in both inlet and outlet comprising 37% to 47% of the total microorganism count. Proteobacteria was followed by Acidobacteria, Actinobacteria and Chloroflexi which comprises 6% to 20%, 9% to 20% and 2% to 27%, respectively of the total microorganism count for each season. These findings were useful in optimizing the design and performance of tree box filters considering physical, chemical and biological pollutant removal mechanisms.

  • PDF

Evaluation of the Septic Tank Performance in the Sewage Treatment Area and Suggestion of an Optimum Model (하수처리구역내 단독정화조의 성능평가 및 최적 모형의 제안)

  • Lim, Bong-Su;Jung, Keum-Hee;Wang, Ze-Jie
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.403-409
    • /
    • 2007
  • This study was carried out to recommend the systematic improving practice for the effective operation of septic tank, and the evaluation of its BOD and nutrient removal efficiency depending on process, the survey of characteristics of FRP material, and the suggestion of optimum septic tank model within sewage treatment area. The average BOD concentration and BOD removal efficiency of septic tank which was carried out the cleaning periodically in 63.9 mg/L and 77.8%, shows good quality better than the septic tank which was not carried out the cleaning regularly. Maximum load of tensile, flexural and compressive strength increased in proportion to its thickness, and the contents standard 25% of glass fiber required upgrade over than 30%. Configuration and performance for the optimum of the septic tank suggests that over $0.75m^3$ of the effective total volume, adding to over $0.25m^3$ a man for more than 5 men of the treated person, retention time should be within one day. Improving plans about facility and materials quality of the septic tank have an obligation that protective wall ought to install on the concrete bottom and side faces to prevent crumble or transform from loading of the ground or upper part of the structure on the tank setting. And it is eliminated the uneffective resisting pressure and it keeps off circulate imperfect products by strengthening of the test methods such as stretching strength, pressing strength, glass fiber contents and thickness.

Analysis of Infiltration Trench Facility for Runoff Reduction Effect (침투트렌치 시설의 유출저감 효과 분석)

  • Yeon, Jong Sang;Jang, Young Su;Shin, Hyun Suk;Kim, Eung Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5813-5819
    • /
    • 2014
  • LID planning and application has been actively developed to reduce the runoff volume at increased impervious areas due to rapid urbanization. In this study, a performance and applicability evaluation was performed in an infiltration trench using the SWMM model, based on the experimental conditions for infiltration trenches. The infiltration trench application area was applied to 5~15% of the drainage area. The SWMM results of discharge and the BOD reduction efficiency were analyzed at a peak discharge of 45.7~61.9%, total discharge of 47.2~62.3%, and BOD load of 52.3~55.3. The discharge and BOD was estimated to be 12~24% higher and 37~38% smaller than the experimental results. This study can help in the application and performance evaluation of infiltration trenches.

Particle loading as a design parameter for composite radiation shielding

  • Baumann, N.;Diaz, K. Marquez;Simmons-Potter, K.;Potter, B.G. Jr.;Bucay, J.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3855-3863
    • /
    • 2022
  • An evaluation of the radiation shielding performance of high-Z-particle-loaded polylactic acid (PLA) composite materials was pursued. Specimens were produced via fused deposition modeling (FDM) using copper-PLA, steel-PLA, and BaSO4-PLA composite filaments containing 82.7, 75.2, and 44.6 wt% particulate phase contents, respectively, and were tested under broad-band flash x-ray conditions at the Sandia National Laboratories HERMES III facility. The experimental results for the mass attenuation coefficients of the composites were found to be in good agreement with GEANT4 simulations carried out using the same exposure conditions and an atomistic mixture as a model for the composite materials. Further simulation studies, focusing on the Cu-PLA composite system, were used to explore a shield design parameter space (in this case, defined by Cu-particle loading and shield areal density) to assess performance under both high-energy photon and electron fluxes over an incident energy range of 0.5-15 MeV. Based on these results, a method is proposed that can assist in the visualization and isolation of shield parameter coordinate sets that optimize performance under targeted radiation characteristics (type, energy). For electron flux shielding, an empirical relationship was found between areal density (AD), electron energy (E), composition and performance. In cases where ${\frac{E}{AD}}{\geq}2MeV{\bullet}cm{\bullet}g^{-1}$, a shield composed of >85 wt% Cu results in optimal performance. In contrast, a shield composed of <10 wt% Cu is anticipated to perform best against electron irradiation when ${\frac{E}{AD}}<2MeV{\bullet}cm{\bullet}g^{-1}$.

Mechanistic-Empirical Guideline for Routine Overweight Truck Traffic Routes (과하중 트럭 운행 도로에 대한 역학적-경험적 지침)

  • Oh, Jeongho
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • The main objective of this research is to develop the Mechanistic-Empirical (M-E) guidelines for evaluating the capacity of existing highways to sustain route overweight truck traffic over a specified performance period due to a growing concern on the impact of increasing overweight truck loads on highways. In this study, a two-stage framework was developed for this purpose. Level I procedure involves the use of pavement evaluation charts to identify the best possible route from among the alternatives considered and to determine what additional tests and analyses are needed as a screening tool. Level II involves the application of the Overweight Truck Route Analysis (OTRA) program to evaluate the structural adequacy of an existing route to carry routine overweight truck traffic over the specified performance period along with estimating asphalt concrete overlay thickness, if necessary.

A Study on the Direction of Restructuring of Educational Facility Management Operating System (학교 교육시설관리 지원시설 업무체계 재구조화 방안 연구)

  • Kim, Young-Bong;Lee, Yong-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.21 no.4
    • /
    • pp.21-28
    • /
    • 2022
  • This study analyzes the reality of the overall operating system, such as recognition and satisfaction with school field support work system of the Education Facilities Management Center, recognition level of restructuring of work areas, and the direction of improvement for school facility maintenance support in various types of future learning environments. To analyze the problem of this study, a survey was conducted on 290 education administrative officials in Gyeonggi-do. First, school site awareness and work performance satisfaction of the Educational Facilities Management Center were evaluated as "below average," and it is necessary to improve the qualitative work area that is practically helpful to schools. Second, in the area of organizational operation, it is desirable to avoid simple tasks with a low evaluation of "below average" and to switch to an operating system that improves efficiency. Third, the need for the facility environment area (professionalism, safety) was the highest, but the center's ability and work processing level were evaluated very low as "below average," so it is urgent to improve the center's capacity. Fourth, in the area of social and educational policy change, the center received a high score for the need for access from the perspective of a learning environment linked to future education. Therefore, a policy review on the restructuring and improvement of work areas suitable for this is necessary.