• 제목/요약/키워드: Performance Demonstration Test

검색결과 137건 처리시간 0.033초

원전 배관 초음파 비파괴검사의 신뢰도 평가 - PD-RR Test Results - (I) (Reliability Assessment of Ultrasonic Nondesturcive Inspection on Piping in NPP - The Result of PD-RR Test - (Part I))

  • 박익근;박은수;김현묵;박윤원;강석철;최영환;이진호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.246-251
    • /
    • 2001
  • The performance demonstration round robin test was conducted to quantify the capability of ultrasonic inspection for in-service and to address some aspects of reliability for nondestructive evaluation. The fifteen inspection teams who employed procedures that met or exceeded ASME Sec. XI code requirements detected the pinping of nuclear power plant with various cracks to evaluate the capability of detection. With data from PD-RR test, the performance of ultrasonic nondestructive inspection could be assessed using probability of detection and length and depth sizing of cracks.

  • PDF

압축 벤토나이트 완충재의 역학 물성 평가 (Evaluation of Mechanical Properties for the Compacted Bentonite Buffer Materials)

  • 윤석;홍창호;김태현;김진섭
    • 한국지반공학회논문집
    • /
    • 제37권10호
    • /
    • pp.5-11
    • /
    • 2021
  • 압축 벤토나이트 완충재는 원자력발전소에서 발생하는 고준위폐기물을 처리하기 위한 공학적방벽시스템의 가장 중요한 요소 중 하나이다. 압축 벤토나이트 완충재는 외부 하중이나 지하수 침투로부터 처분 용기를 보호하기에, 열-수리-역학적인 요구 조건을 충족하여야 한다. 이러한 완충재의 열-수리 물성에 관한 연구는 많이 진행되어 왔지만, 역학 물성 규명에 관한 연구는 많이 부족한 실정이다. 이러한 이유로, 본 연구에서는 건조밀도와 함수비에 따른 다양한 국내 압축 벤토나이트 시료를 조성하여 이에 대한 일축압축강도시험을 실시하였으며, 일축압축강도, 탄성계수, 그리고 포아송비를 도출하였다. 압축 벤토나이트의 일축압축강도와 탄성계수는 건조밀도에 따라 증가하였으며, 포아송비는 건조밀도가 증가할수록 약간 감소하는 것으로 나타났다. 일축압축강도, 탄성계수 및 포아송비는 건조밀도와 큰 상관 관계를 보였으나, 함수비와는 특별한 상관성을 나타내지는 않았다.

PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구 (An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber)

  • 주홍진;곽희열
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

태양열 냉.난방 및 급탕 시스템 열성능 (Evaluation of thermal performance for solar cooling and heating system)

  • 곽희열;주홍진;이호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.203-208
    • /
    • 2009
  • This paper presents demonstration study results derived through field testing of a solar assisted cooling and heating system for the library of a cultural center building located in Gwangju, Korea. The area of demanded cooling and heating for building was about 350m2. Solar hot water was delivered by means of a 200m2 array of evacuated tubular solar collector (ETSC) to drive a single-effect (LiBr/H2O) absorption chiller of 10RT nominal cooling capacity. From March in 2008 to February in 2009, demonstration test were performed for solar cooling and heating system. After experiments and analysis, this study found that solar thermal system was 84% for the solar hot water supply and 12% for space heating and 4% for space cooling.

  • PDF

태양열 온수기 실증연구를 통한 성능 평가 (Performance Evaluation of Solar Water Heating System Using Proof Test)

  • 김재열;곽이구;양동조;최철준;김홍건
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.597-601
    • /
    • 2006
  • The advantages of solar energy are that it is renewable, infinite supplied and environmentally safe energy source. However, solar energy related products have the problems such as the limitation for installation, problems in maintenance and insufficient reliability which have been the barrier to consumers to satisfy the purchase need for solar heat related products. In this regard, in order to support the solar energy related companies the necessity for various technical information required for the commercialization of new products such as various performance test necessary for the certification of solar energy system, standardization for facilities and products, performance evaluation method and the measurement of performance is suggested. The purpose of this paper is to design the monitoring system for positive tests of system linked household hot water system using solar heat out of various solar energy systems, to establish an analysis and monitoring system for performance maintenance and operation technique, and to configure the centralized detection network by utilizing remote monitoring system. This research also aims at conducting monitoring for operation and performance evaluation in relation to database establishment and analytical evaluation and at describing the method of enhancing the reliability of solar energy system through the development of performance evaluation program.

  • PDF

750kW급 Gearless형 국산화 풍력발전시스템 (750kW Gearless Type Wind Turbine Generator System)

  • 류지윤;박진일;김대현;황진수;김두훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.245-248
    • /
    • 2006
  • The first of korean 750kW gearless type wind turbine is developed. The wind turbine is designed, manufactured and tested by GE regulation and obtained the design certificate by GL. And the performance test is being performed at the demonstration site now. This paper presents the history of development and performance test for 750kW gearless type wind turbine.

  • PDF

원전 배관 결함의 크기측정성능에 대한 초음파 검사시스템의 확률론적 신뢰도 평가 (Probabilistic Reliability Analysis of Ultrasonic Inspection System about Sizing Performance of Defects in Piping on Nuclear Power Plant)

  • 김현묵;정지홍;지용우;장경영;박익근;박윤원
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2002년도 정기학술대회
    • /
    • pp.217-224
    • /
    • 2002
  • The performance demonstration round robin test was conducted to quantify the capability of ultrasonic inspection for in-service and to address some aspects of reliability for nondestructive evaluation. The fifteen inspection teams who employed procedures that met or exceeded ASME Sec. XI code requirements detected the piping of nuclear power plant with various cracks to evaluate the capability of detection. With data from PD-RR test, the performance of ultrasonic nondestructive inspection could be assessed using probability of length and depth sizing of cracks.

  • PDF

75톤급 가스발생기 기술검증시제의 연소시험 (Hot-firing Test of Technology Demonstration Model Gas Generator for 75 ton-class Liquid Rocket Engine)

  • 안규복;서성현;김문기;임병직;김종규;이광진;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.225-228
    • /
    • 2009
  • 추력 75톤급 액체로켓엔진용 기술개발/검증 시제인 가스발생기의 연소시험이 수행되었다. 가스발생기 분사기 및 헤드의 성능을 먼저 확인하기 위해 heat-sink 형태의 연소실이 사용되었다. 본 논문에서는 연소시험을 위한 준비상황 및 기술검증시제 연소시험에서 얻어진 압력, 온도 분포, 압력 섭동 등의 결과들을 설명하였다.

  • PDF

도시형 자기부상열차 추진특성에 관한 성능연구 (Research of Performance for the Propulsion System of Maglev Vehicle)

  • 김봉섭;고준균;박도영;강병관
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2342-2347
    • /
    • 2011
  • This paper introduces the performance test of the prototype vehicle, which will be in operation for Urban Maglev Program. While common trains with steel wheels use rotary induction motors for propulsion, maglev trains gain thrust force from linear induction motors maintaining the constant airgap with levitation electromagnets. Therefore, not only the behavior of the linear induction motor should be well understood, but also the way of propulsion that minimizes its effect on the levitation system should be took into account. Performance test procedures of maglev trains are proposed and carried out, and the characteristics of acceleration and deceleration are verified to agree with the design criteria. Tests are mainly performed on the linear section of the test line, and the driving characteristics on the section with a 6‰ incline are examined additionally. As a result, the performance of the prototype vehicle in the reverse operation can satisfy the requirement about the acceleration and deceleration, 4.0$m/s^2$. And, the design modifications of the commercial vehicle and the performance specifications required on the demonstration line are investigated.

  • PDF

Monitoring and Analysis of 3kW Grid-Connected PV System for Performance Evaluation

  • So Jung-Hun;Jung Young-Seok;Yu Gwon-Jong;Choi Ju-Yeop;Choi Jae-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.57-62
    • /
    • 2005
  • Grid-connected photovoltaic (PV) systems were installed and monitored at the field demonstration test center (FDTC) in Korea in October 2002. Before long-term field testing of installed PV systems, the performances of PV components were evaluated and compared through short-term performance tests of each of the PV system components such as power conditioning system and PV module under standard test conditions. A data acquisition system has been constructed for measuring and analyzing the performance of PV systems to observe the overall effect of environmental conditions on their operation characteristics. Performances of PV systems have been evaluated and analyzed not only for component perspective (PV array, power conditioning unit) but also for global perspective (system efficiency, capacity factor, electrical power energy) by review of the field test and loss factors of the systems. These results indicate that it is highly imperative to develop an optimum design technology of grid connected PV systems. The objective of this paper is not only to evaluate and analyze the performance of domestic PV systems application through long-term field testing at FDTC but also to develop evaluation, analysis and optimum technology for long-term stability and reliability of grid-connected PV systems in Korea.